THE STARTING CHARACTERISTICS IMPROVEMENT OF SPIM WITH ONE-CHIP MICROCONTROLLER

  • Park, Su-Kang;Choi, Nak-Il;Cho, Geum-Bae;Oh, Keum-Gon;Baek, Hyung-Lae;Lim, Yang-Su
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.321-324
    • /
    • 1998
  • A single phase induction motor (SPIM) rated in fractional horsepower is widely used in home and industrial equipment: washing machines, fans, refrigerators, etc. In this paper, authors present the experimental results of the SPIM under controlling of currents of main and auxiliary windings by using a one-chip micro stator(OMS). This new starting method is developed to replace the conventional starting device consisted with a mechanical switch and a capacitor. In mentioned method, the soft-starting of SPIM is simply implemented and higher efficiency is obtained in comparison with conventional condenser type SPIM.

  • PDF

A Research of Data Gathering Middleware and User Friendly Display for vessel PMS(Planned Maintenance System) (선박 PMS를 위한 데이터 수집 미들웨어와 사용자 편의적 디스플레이연구)

  • Lee, Seojeong
    • Journal of Information Technology Services
    • /
    • v.12 no.2
    • /
    • pp.335-348
    • /
    • 2013
  • Vessel PMS (Planned Maintenance System) is a paper and/or software based system to monitor vessel engine equipment including main propulsion, steering, auxiliary machinery and cargo handling information. This is one of mandatory survey for vessel introduced by IMO (International Maritime Organization). The planned maintenance as well as documentation must be performed according to a system to be approved by classification agencies. Recently, vessel owners have preferred software based systems to collect and preserve accurate data. However, not ship specific and not taking into account the user are said by end users as operational difficulties. To relieve these concerns, this research analyzes vessel PMS data, suggests a middleware to support automatic collection and design consideration of user interface.

Uncertainty-Compensating Neural Network Control for Nonlinear Systems (비선형 시스템의 불확실성을 보상하는 신경회로망 제어)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1597-1600
    • /
    • 2010
  • In this paper, a direct controller for nonlinear plants using a neural network is presented. The composed of the control input by using RBF neural networks and auxiliary input to compensate for effects of the approximation errors and disturbances. In the results, using this scheme, the output tracking error between the plant and the reference model can asymptotically converge to zero in the presence of bounded disturbances and approximation errors. Simulation results show that it is very effective and can realize a satisfactory control of the nonlinear system.

Optimal Design of Electric Vehicle Cross Beam for Adaptive Design of Homogenized Structure (균질화된 구조의 적응설계를 위한 전동차 크로스 빔의 최적설계)

  • 백석흠;이경영;조석수;장득열;주원식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.85-93
    • /
    • 2004
  • Electric vehicle body has to be subjected to uniform load and requires auxiliary equipment such as air pipe and electric wire pipe. Especially, the cross beam supports the weight of passenger and electrical equipments. This need to use adaptive design in initial design stage to gain economy through interchangeability between many kinds of components. This study performs the topology optimization by the concept of homogenization based on optimality criteria method which is efficient for the problem with a number of boundary condition and design variable. Therefore this provides the method to determine the optimum position and the shape of circular hole in the cross beam and then can achieve the weight minimization of electric vehicle body.

The stability analysis on large sectional tunnel station considering construction steps (시공단계를 고려한 대단면 정거장 터널 안정성 해석)

  • Kang, Eun-Gu;Kim, Yang-Woon;Ahn, Kyeong-Cheol;Han, Myeong-Sik
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1062-1068
    • /
    • 2009
  • Urban construction has numerous difficulties due to ground weakness and various complaints from third party, so it is not economically efficient and constructability is not favorable. Therefore, underground, which has good ground conditions, was used for construction field and facilities such as stations, and they are scaled up to enhance accommodation of facility limitation and function of stations. Large section tunnel station construction has numerous risk factors such as work boundary of excavation equipment, a relaxation of stress concentration, a safety plan of tunnel stability, and so on. Therefore, by using large section tunnel station stability analysis considering construction step, we expect to analyze the latent problem during construction, and to stabilize a future project plan of a large section structure design by using an auxiliary method and a support design.

  • PDF

A Study on the Topology Optimization of Electric Vehicle Cross beam using an Optimality Criteria Method in Determination of Arranging Hole (원공배열 결정에 최적기준법에 의한 전동차 크로스 빔의 위상최적화에 관한 연구)

  • 전형용;천홍정;송시엽;최중호
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.876-883
    • /
    • 2002
  • Electric vehicle body has to be subjected to uniform load and requires auxiliary equipment such as air pipe and electric wire pipe. Especially, the cross beam supports the weight of passenger and electrical equipments. a lightweight vehicle body is salutary to save operating costs and fuel consumption. Therefore this study is to perform the size and the shape optimization of crossbeam fur electric vehicle using the method of topology optimization to introduce the concept of homogenization based on optimality criteria method which is efficient for the problem having the number of design variables and a few boundary condition. this provides the method to determine the optimum position and shape of circular hole in the cross beam and then can achieve the optimal design to reduce weight.

  • PDF

Flow Characteristics of the Servo Valve in the Fuel Supply System of APU (보조 동력 장치 연료 공급용 서보밸브의 유동 특성 해석)

  • Kim, S.S.;Chang, S.M.;Jeong, H.S.;Ryu, H.;Lee, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • In this paper, the authors benchmark a servo valve model for the fuel supply system of Auxiliary Power Unit (APU) in the KHP helicopter. This valve is directly driven with a torque motor, and the size of small gap controlled by a flapper can make change of flow rate under given pressure drop between inlet and outlet. CFD analyses using a commercial code, ANSYS-CFX 10 are performed for the series of three-dimensional models at various openness conditions. The computational results on simplified models show that CFD can play a fine roll in the design of flow path as well as in the estimation of flow force due to its precision and good repeatability. Consequently, the CFD analysis helps valve designers to understand its flow characteristics from the basis of physical fundamentals.

  • PDF

Development of Static Inverter for European Electric Railway (유럽형 전동차용 보조전원장치 개발)

  • Kim Sangkyun;Kim Ki-Hoon;Lee Hyun-Seok;Lee Kyung-Bok;Choi Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.634-639
    • /
    • 2003
  • The static inverter is mainly used to provide with the electric power of various loads in the train. In the recent european projects, the specification of static inverter become harder, and many additional service function is expected. It takes long time and high cost to develope a static inverter with these high performances and additional function. But, these are became general demands for static inverter in the many projects from now on. The APSE(Auxiliary Power Supply Equipment) is a static inverter of high performance to satisfy the severe specification and various service function following these tendency for Athens project In this paper, the specification of APSE and various service functions are introduced to look about current tendencies of static inverter.

  • PDF

Harmonics Measurement and Analysis for Power Electronic Equipments of Korea High Speed Train Prototype (고속전철 전력변환장치에서의 고조파 계측 및 분석)

  • Lee Tae-Hyung;Jang Dong-Uk;Park Choon-Soo;Mok Jin-Yong;Shin Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1382-1384
    • /
    • 2004
  • It is essential to evaluate harmonic characteristics of high speed train using power electronics equipment such as converter-driven motor drives, battery chargers and auxiliary power supplies. The purpose of this study is to measure and analyze harmonics characteristics of korea high speed train prototype. This paper presents result of harmonics measurement and analysis of harmonics characteristics in terms of loading, speed and operation mode.

  • PDF

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.