• Title/Summary/Keyword: Auxiliary Solution

Search Result 110, Processing Time 0.021 seconds

Efficient MCS for random vibration of hysteretic systems by an explicit iteration approach

  • Su, Cheng;Huang, Huan;Ma, Haitao;Xu, Rui
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.119-139
    • /
    • 2014
  • A new method is proposed for random vibration anaylsis of hysteretic systems subjected to non-stationary random excitations. With the Bouc-Wen model, motion equations of hysteretic systems are first transformed into quasi-linear equations by applying the concept of equivalent excitations and decoupling of the real and hysteretic displacements, and the derived equation system can be solved by either the precise time integration or the Newmark-${\beta}$ integration method. Combining the numerical solution of the auxiliary differential equation for hysteretic displacements, an explicit iteration algorithm is then developed for the dynamic response analysis of hysteretic systems. Because the computational cost for a large number of deterministic analyses of hysteretic systems can be significantly reduced, Monte-Carlo simulation using the explicit iteration algorithm is now viable, and statistical characteristics of the non-stationary random responses of a hysteretic system can be obtained. Numerical examples are presented to show the accuracy and efficiency of the present approach.

Analytical study of house wall and air temperature transients under on-off and proportional control for different wall type

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.1
    • /
    • pp.70-81
    • /
    • 2010
  • A mathematical model is formulated to study the effect of wall mass on the thermal performance of four different houses of different construction. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one -dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures is obtained using the Laplace transform method. Typical Meteorological Year data are processed to yield hourly average monthly values. These discrete data are then converted to a continuous, time dependent form using a Fast Fourier Transform method. This study is conducted using weather data from four different locations in the United States: Albuquerque, New mexico; Miami, Florida; Santa Maria, California; and Washington D.C. for both winter and summer conditions. A computer code is developed to calculate the wall temperature profile, room air temperature, and energy consumption loads. Three sets of results are calculated one for no auxiliary energy and two for different control mechanism -- an on-off controller and a proportional controller. Comparisons are made for the cases of two controllers. Heavy weight houses with insulation in mild weather areas (such as August in Santa Maria, California) show a high comfort level. Houses using proportional control experience a higher comfort level in comparison to houses using on-off control. The result shows that there is an effect of mass on the thermal performance of a heavily constructed house in mild weather conditions.

A Two-Phase Interleaved Bidirectional DC-DC Converter with Zero-Voltage-Transition (영 전압 천이를 갖는 2상 인터리브드 양방향 DC-DC 컨버터)

  • Lim, Chang-Soon;Ku, Nam-Joon;Kim, Min-Sub;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • The two-phase interleaved bidirectional DC-DC converter (TIBDC) is a very attractive solution to problems related to battery energy storage systems. However, the hard-switching TIBDC increases the switching loss and electromagnetic interference noise when the switching frequency increases. Hence, a soft-switching technique is required to overcome these disadvantages. In this study, a novel TIBDC with zero-voltage transition (TIBDC-ZVT) is proposed. Soft switching in the boost and buck main switches is achieved through a resonant cell that consists of a single resonant inductor and four auxiliary switches. Given its single resonant inductor, the proposed TIBDC-ZVT has a reduced size and can easily be implemented. The validity of the proposed TIBDC-ZVT is verified through experimental results.

An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers

  • Lu, Zheng;Wang, Dianchao;Masri, Sami F.;Lu, Xilin
    • Smart Structures and Systems
    • /
    • v.18 no.1
    • /
    • pp.93-115
    • /
    • 2016
  • A particle tuned mass damper (PTMD) system is the combination of a traditional tuned mass damper (TMD) and a particle damper (PD). This paper presents the results of an experimental and analytical study of the damping performance of a PTMD attached to the top of a benchmark model under wind load excitation. The length ratio of the test model is 1:200. The vibration reduction laws of the system were explored by changing some system parameters (including the particle material, total auxiliary mass ratio, the mass ratio between container and particles, the suspending length, and wind velocity). An appropriate analytical solution based on the concept of an equivalent single-unit impact damper is presented. Comparison between the experimental and analytical results shows that, with the proper use of the equivalent method, reasonably accurate estimates of the dynamic response of a primary system under wind load excitation can be obtained. The experimental and simulation results show the robustness of the new damper and indicate that the damping performance can be improved by controlling the particle density, increasing the amount of particles, and aggravating the impact of particles etc.

Static analysis of functionally graded non-prismatic sandwich beams

  • Rezaiee-Pajand, M.;Masoodi, Amir R.;Mokhtari, M.
    • Advances in Computational Design
    • /
    • v.3 no.2
    • /
    • pp.165-190
    • /
    • 2018
  • In this article, the static behavior of non-prismatic sandwich beams composed of functionally graded (FG) materials is investigated for the first time. Two types of beams in which the variation of elastic modulus follows a power-law form are studied. The principle of minimum total potential energy is applied along with the Ritz method to derive and solve the governing equations. Considering conventional boundary conditions, Chebyshev polynomials of the first kind are used as auxiliary shape functions. The formulation is developed within the framework of well-known Timoshenko and Reddy beam theories (TBT, RBT). Since the beams are simultaneously tapered and functionally graded, bending and shear stress pushover curves are presented to get a profound insight into the variation of stresses along the beam. The proposed formulations and solution scheme are verified through benchmark problems. In this context, excellent agreement is observed. Numerical results are included considering beams with various cross sectional types to inspect the effects of taper ratio and gradient index on deflections and stresses. It is observed that the boundary conditions, taper ratio, gradient index value and core to the thickness ratio significantly influence the stress and deflection responses.

Supplementary Event-Listener Injection Attack in Smart Phones

  • Hidhaya, S. Fouzul;Geetha, Angelina;Kumar, B. Nandha;Sravanth, Loganathan Venkat;Habeeb, A.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.10
    • /
    • pp.4191-4203
    • /
    • 2015
  • WebView is a vital component in smartphone platforms like Android, Windows and iOS that enables smartphone applications (apps) to embed a simple yet powerful web browser inside them. WebView not only provides the same functionalities as web browser, it, more importantly, enables a rich interaction between apps and webpages loaded inside the WebView. However, the design and the features of WebView lays path to tamper the sandbox protection mechanism implemented by browsers. As a consequence, malicious attacks can be launched either against the apps or by the apps through the exploitation of WebView APIs. This paper presents a critical attack called Supplementary Event-Listener Injection (SEI) attack which adds auxiliary event listeners, for executing malicious activities, on the HTML elements in the webpage loaded by the WebView via JavaScript Injection. This paper also proposes an automated static analysis system for analyzing WebView embedded apps to classify the kind of vulnerability possessed by them and a solution for the mitigation of the attack.

X-Ray Diffractometric Study on Modification Mechanism of Matrixes for Electrothermal AAS Determination of Volatile Lead and Bismuth

  • Kim, Yeong Sang;Choe, Jong Mun
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.56-60
    • /
    • 2000
  • The mechanism of a matrix modification for the trace determination of volatile lead and bismuth by an electro-thermal atomic absorption spectrophotometry was studied by a X-ray diffractometry (XRD). For the investigation of structures, the ash products of the elements were produced by using a palladium as a matrix modifier with or without aluminum or nickel as an auxiliary modifier. The same charring conditions as in the analysis of samples were applied together with much concentrated solution of analytical elements and modifiers in a graphite furnace to get a large amount of the product for XRD. The XRD patterns showed PbPd3 for lead and BiPd3 for bismuth. These mean that the reaction procedures through the charring and atomization were changed from $Pb^{2+}$ ${\rightarrow}$ PbO ${\rightarrow}$$Pb^0$ to $Pb^{2+}$ ${\rightarrow}$ PbO ${\rightarrow}PbPd_3$ ${\rightarrow}$ Pb o for lead and from $Bi^{3+}$ ${\rightarrow}$ BiO ${\rightarrow}$ Bi o to $Bi^{3+}$ ${\rightarrow}$ BiO ${\rightarrow}$ $BiPd_3$ ${\rightarrow}$ $Bi^0$ for bismuth by the addition of modifiers. The volatile elements were stabilized by the formation of palladium alloys through a charring process. Charring temperatures were raised about 500 $^{\circ}C$ by the alloying and the atomization was also stabilized for the enhancement of sensitivities.

Analysis of Efficiency Enhancement of the Integrated Gasification Combined Cycle with Oxy-Combustion Carbon Capture by Changing the Oxygen Supply System (순산소연소 이산화탄소 포집을 적용한 석탄가스화 복합화력 발전시스템에서 산소공급방식 변경에 의한 효율향상 분석)

  • CHO, YEON WOO;AHN, JI HO;KIM, TONG SEOP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.347-355
    • /
    • 2019
  • As a solution to the growing concern on the global warming, researches are being actively carried out to apply carbon dioxide capture and storage technology to power generation systems. In this study, the integrated gasification combined cycle (IGCC) adopting oxy-combustion carbon capture was modeled and the effect of replacing the conventional air separation unit (ASU) with the ion transport membrane (ITM) on the net system efficiency was analyzed. The ITM-based system was predicted to consume less net auxiliary power owing to an additional nitrogen expander. Even with a regular pressure ratio which is 21, the ITM-based system would provide a higher net efficiency than the optimized ASU-based system which should be designed with a very high pressure ratio around 90. The optimal net efficiency of the ITM-based system is more than 3% higher than that of the ASU-based system. The influence of the operating pressure and temperature of the ITM on system efficiency was predicted to be marginal.

Analysis of the Emission Benefits of Using Alternative Maritime Power (AMP) for Ships

  • Kim, Kyunghwa;Roh, Gilltae;Chun, Kangwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.381-394
    • /
    • 2019
  • The marine industry contributes a large proportion of the air pollutant emissions along coastal regions, and this air pollution has been strongly linked to cardiovascular diseases and other illnesses. To alleviate the problem, many ports have installed alternative maritime power (AMP) facilities that enable onboard marine auxiliary engines with generators (gensets) to be shut down while a ship is at berth. This study compared the emissions from conventional gensets with those from AMP facilities, focusing on four emission types: greenhouse gases (GHG), sulphur oxides (SOX), nitrogen oxides (NOX), and particulate matter (PM). Both direct (combustion / operation) and indirect (upstream) emissions were considered together for the emission comparison. The results showed that AMP has lower emissions than conventional onboard gensets, and this benefit is highly dependent on the electricity generation mix onshore. On average, GHG emissions could be reduced by about 18.3 %, while the other emissions (SOX, NOX, and PM) would decrease more dramatically (88.4 %, 90.1 %, and 91.5 %, respectively). Additionally, future benefits of the AMP would increase due to the expansion of renewable energies. Thus, this study supports the potential of AMP as a promising solution for environmental concerns at ports worldwide.

Meander Flume Outlet Sediment Scour Analysis of a Boxed Culvert

  • Thu Hien Thi Le;VanChienNguyen;DucHauLe
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.35-35
    • /
    • 2023
  • The main reason for its instability is sediment scouring downstream of hydraulic structures. Both physical and numerical models have been used to investigate the influence of soil properties on scour hole geometry. Nevertheless, no research has been conducted on resistance parameters that affect sedimentation and erosion. In addition, auxiliary structures like wing walls, which are prevalent in many real-world applications, have rarely been studied for their impact on morphology. The hydraulic characteristics of steady flow through a boxed culvert are calibrated using a 3D Computational Fluid Dynamics model compared with experimental data in this study, which shows a good agreement between water depth, velocity, and pressure profiles. Test cases showed that 0.015 m grid cells had the lowest NRMSE and MAE values. It is also possible to quantify sediment scour numerically by testing roughness/d50 ratios (cs) and diversion walls at a meander flume outlet. According to the findings, cs = 2.5 indicates a close agreement between numerical and analytical results of maximum scour depth after the culvert; four types of wing walls influence geometrical deformation of the meander flume outlet, resulting in erosion at the concave bank and deposition at the convex bank; two short headwalls are the most appropriate solution for accounting for small changes in morphology. A numerical model can be used to estimate sediment scour at the meander exit channel of hydraulic structures based on the roughness parameter of soil material and headwall type.

  • PDF