• 제목/요약/키워드: Automatic water control system

검색결과 195건 처리시간 0.034초

의령수역의 자동화 물관리 시스템 운영개선연구 (A study on Improvement of Automatic Water Management System in Uiryeong Watershed Area)

  • 조영제;이명준;김영호;박상현
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.213-214
    • /
    • 2005
  • Uiryung Watershed area, located at the confluence of Nam River and Nagdong River has 9000 ha of agricultural land area and 3024 ha of paddy rice field have been reclaimed and managed by Korean Agricultural and Rural Infrastructure Corporation(KARICO) in the riparian area since 1954. In spite of irrigation and drainage improvement projects in last 3 decades since 1970, there are severe drought and innundation problems in the area. To improve the difficulties and efficient usage of irrigation water not only for agriculture but also for environmental conservation and cultural ceremony, Automatic Water management system has been installed supported by Ministry of Agriculture and Fishery in Korean Government. The control office in Uiryung Branch Office of KARICO, receive all the water management records from Remote Terminal Units in 7 reservoirs and 26 Pump stations to operate the decision supporting system of irrigation and drainage facility during cropping period. Since the completion of the water management system at the end of 2003, the electric cost decrease in 80 % than average years. In spite of decrease of two technical assistants since 2004, complains from farmers for the water management are very rare. The technological experience from the automatic water management system would contribute not only for the efficient water management of Uiryang area but also for the modernization of water management of other watershed areas in the future.

  • PDF

The Development of the Automatic Discharge Acquisition & Management System (ADAMS) using Ubiquitous Technique

  • Park, Jae-Young;Oh, Byoung-Dong;Jeon, Seon-Mee;Kim, Jae-Bok
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.488-493
    • /
    • 2006
  • Accurate river discharge is the most important factor in managing river basins and for successfully maintaining total maximum daily loads in Korea. It is not easy to measure the discharge directly in large rivers owing to physical and environmental constraints, even after investing much time and money. Recently, to overcome these historical drawbacks in river discharge measurement, we have developed the Automatic Discharge Acquisition & Management System (ADAMS) that scans the river cross-section and measures each cell $(1m{\times}1m)$ velocity using HADCP. The hardware system is composed of an HADCP sensor and winch, as well as a PC and software system for the discharge calculation module and hardware control module. It is controlled remotely via the internet and uses the velocity-depth integration method and the velocity-contour method for calculating river discharges. The characteristics of ADAMS are a ubiquitously accessible system, featuring real time automatic discharge measurement, remote control via the internet. The results using ADAMS at the Jindong stage site show less than 5% uncertainty and are 4 times more efficient than the ADCP & Q-boat system. This system can be used to measure any large river, river mouth or tributary river affected by backwater, all of which have a very difficult measuring real time discharge. The next generation of ADAMS will feature an upgrade to increase portability and GPS integration.

  • PDF

수경재배(水耕栽培)의 양액관리(養液管理) 자동화(自動化) 시스템 개발(開發) (Development of Nutrient Solution Control System for Water Culture)

  • 이기명;이주성;선철호;장익주;송재관;구건효
    • Journal of Biosystems Engineering
    • /
    • 제15권4호
    • /
    • pp.328-338
    • /
    • 1990
  • The objective of this study was to develop automatic systems of nutrient solution management for optimal nutrient solution environment and labor saving in water culture which enables factory crop production. In this study, an automatic control system and its driving program are developed to prepare, supply, and recover nutrient solution and to keep the optimal solution concentration level using microcomputers. Based on this study, the following conclusions are obtained: 1. The concentration measured by the system using oscillating circuit designed and built in this study, gave good agreements with the actual nutrient solution. 2. In water culture, the period of 12 hours for measuring concentration, pH, and temperature of the nutrient solution was optimum. Addition of control solution due to the decrease of the nutrient solution concentration is required in every 3 to 5 days. 3. It is estimated that the period of the whole solution change is 15 days, however, further research is needed to assure it. In addition, this period must be shortened in the future. 4. Both the hardware and software of the developed optimal nutrient solution control system in the water culture are working very well, however, it is necessary to develop a more economical one-chip micro controller to substitute for the microcomputer.

  • PDF

Development and Field Assessment of DO Control System in an Aeration Tank for Automation of Sewage Treatment Plant

  • Jung, In-Chul;Kim, Dae-Yong;Junq, Byung-Gil
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.603-608
    • /
    • 2009
  • Activated sludge sewage treatment processes are difficult to be controlled because of their complex and nonlinear behaviour, however, the control of the dissolved oxygen level in the reactors plays an important role in the operation of the facility. For this reason, this study is designed to present a system which accurately measures DO, MLSS, pH and ORP in the aeration tank to alleviate situations above and provide the automatization of a sewage treatment plant (STP) using new DO control system. The automatic control systems must be guaranteed the accuracy. Therefore, the proposed automatic DO control system in this study could be commercial applications in the aeration tanks by means of operating cost analysis and user-friendly for operation and maintenance. We could get accurate data from the lab tank which has water quality checker because there was no vortex and air bubble during the measurement process. Improvement of confidence in the lab tank enabled effective and automatic operation of sewage treatment plants so that operation costs and manpower could be saved. If this result is put in place in every sewage treatment plant nationwide for practical purposes, it is estimated to cost 18.5 million dollars in installing the lab tank and to save 9.8 million dollars in management cost a year, except for cost saved by automation.

The Development Measuring System of Temperature Effect to Produce Electric Power of Solar Cell

  • Sadmai, Ong-art
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.104-113
    • /
    • 2015
  • This paper focuses on a temperature effects on a PV panel which has been installed in Thailand. The main objective is cleaning PV panels and reduce temperature of PV panel by water injects from waterway and experimental results of PV power what it is difference. This project is designed by PLC control system which water injects and control PV temperature, In addition, this project consists of hardware and software such as water pump, water injection and PLC control has been automatically and it can be control system manually. The automatic control system is working when PV temperature rises up over 45 degree Celsius after that the pumping machine would inject water to the surface of PV panels and it must be stop when the PV panel temperature comes down less than 45 degree Celsius. The result of actual experimental found that the control system has been done correctly under specify condition. The experimental has been shown electrical data before and after water injects on PV system found that the electrical power a bit increases and The energy has been taken from PV panel less than energy consumption equipment of control system which taken to operate the water injecting system.

액제 정밀계량장치를 이용한 액제 자동조제 시스템개발 (Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device)

  • 류관희;홍순호;이규철;이정훈;황호준
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

센서네트워크 환경 기반의 자동 분무기 제어시스템의설계 및 구현 (Design and Implementation the Control System of Automatic Spry Based on Sensor Network Environment)

  • 곽윤식;구본근;정승국
    • 한국항행학회논문지
    • /
    • 제15권1호
    • /
    • pp.91-96
    • /
    • 2011
  • 본 논문은 센서네트워크 기반으로 설계, 구현된 자동 분무기 시스템의 관리를 위한 제어 시스템의 설계에 관한 것이다. 실시간, 대량의 센싱 데이터의 수집 그리고 분석을 통하여 실시간의 맞춤형 응답처리를 수행할 수 있도록 이벤트 기반 서비스 처리 기술을 적용하였다. 센서 제어 시스템-온/습도 센서 입력 데이터, 수위 센서 입력 데이터, 수온 센서 입력 데이터-을 설계하였으며 입력된 센서 데이터의 분석을 통하여 실시간으로 출수 및 압축공기 토출을 제어하는 자동 분무기 제어 시스템을 설계하였다. 실험을 통하여 제안 시스템을 적용하는 경우, 온도는 33% 그리고 습도에 대해서는 37.3%의 개선 효과를 나타냄으로서 안정적인 온/습도 관리가 가능하게 되었다.

레디믹스트 콘크리트 플랜트의 회수수 농도 측정 자동화에 관한 연구 (A Study on the Automatic Measurement of Solid Content in Recycled Water in Ready Mixed Concrete Plant)

  • 최영철;문규돈;조봉석
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.123-131
    • /
    • 2014
  • Whole amount of waste water, approximately 921.6 liter, for cleaning a ready mixed concrete truck should be used to produce concrete as a mixing water or cleaning water. Recycling water for concrete mixing contains solids, which cause decrease in slump, air and compressive strengths, so it may influence on poor concrete quality. Therefore, it has been maintained to use recycling water with less than 3 percent of solids. Since no evaluation system has been constructed to directly reflect on variability of recycling water from ready mixed concrete plants, it is necessary to develop "Automatic recycling solid measuring system" for quality controls in real time. In this research, sensors measuring waste water concentration in ultrasonic and inductance methods were developed, and automatic system using the sensors were established. The accuracy of measurement sensors developed for recycling water based on various conditions of concentration was proved, and application limits were evaluated. Also, concentration of recycling water using sensors developed from ready mixed concrete plant was measured, and curing method verified the accuracy of the sensors. Moreover, measurement sensors for recycling water in various locations were installed to evaluate the effects on measuring method and spots. The automatic measuring system for recycling water concentration, which is developed in the research, will contribute to improve concrete quality safety through reliable solids maintenance.

자동 안개 채취기 개발 (Development of an Automatic Fog Water Collector)

  • 이승규;신상열;김진영;김만구;김희갑;김민건;성주헌;박찬원;김일환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.385-385
    • /
    • 2000
  • In this paper, We presents the development of an automatic fog water collector that operates during fog events. This collector consists of fraction collectors, a wind hall and a fog sensor. If a fog event occurred, then the fog sensor wouldjudge whether it is a fog or not. If the fog sensor judged the fug, then the fog in the air would be rucked by suction fans. At the same time, the wind direction, the wind velocity, the atmospheric temperature and the atmospheric pressure would be measured and recorded. We are also developing a wireless communication system for the remote control and the remote data analysis in order to collect, store and process the data collected in the automatic fog water collector.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.