• Title/Summary/Keyword: Automatic test stand

Search Result 6, Processing Time 0.022 seconds

Conceptual Design on the C-9N Test Stand for Small-sized Gas Turbine (소형가스터빈용 C-9N 스탠드 설비에 대한 개념설계)

  • Kim, Sang-Hwa;Han, Poong-Gyoo;Kim, Young-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.325-328
    • /
    • 2007
  • In this study, intended to high flight condition test, air flow test and environmental condition test of Small-sized Gas Turbine (including auxiliary power utility - APU) improve preexisting large size test stand C-9N(SCIAM) in Russia. In the process of developing C-9N test stand, this study includes conceptual design approach. This test stand consists of environmental condition, thermostat, cooling/drying, thrust measuring system and SAR (system of automatic regulation).

  • PDF

Stand-Alone Pico-Hydro Generation System using a High-Efficiency IPM Synchronous Generator

  • Kurihara, Kazumi;Kubota, Tomotsugu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.121-125
    • /
    • 2014
  • This paper presents a successful stand-alone pico-hydro generation system using a high-efficiency interior permanent-magnet (IPM) synchronous generator. A 1-kW 4-pole V-type IPM generator with low voltage regulation is used for laboratory test in stand-alone hydro energy conversion system. It has been found from experimental results that the constant output voltage is supplied stably by the proposed system under wide speed range.

A Study on the Usability Test of People with Disabilities According to the Development of Powered Wheelchair of Standing Support Type (기립보조형 전동휠체어 개발에 따른 장애인 사용성 평가 연구)

  • Rhee, Kun-Min;Kim, Dong-Ok;Hwangbo, Chi-Wook
    • 재활복지
    • /
    • v.20 no.1
    • /
    • pp.211-233
    • /
    • 2016
  • The purpose of this study is to figure out problems and to suggest improvement scheme by examining 31 of the disabled who used power wheelchair developed for safe moving and standing support. The results are as follows. First, standing power wheelchair that enables the disabled to sit and stand up was developed. It can also be used as means of transportation for moving in narrow space and in a short distance. In the usability test of this prototype, two groups were respectively examined in 60 evaluation items. One group consisted of 16 people with disabilities using manual wheelchairs. And the other one consisted of 15 people with disabilities using automatic wheelchairs. The entire average figure of two groups was shown to be 2.72 and standard deviation was 0.820. Specifically, the average figure of the group in manual wheelchair was 2.85 and the one of the other group in automatic wheelchair was 2.57. And both group replied that the move to stand up and sit on both types of wheelchair was the most inconvenient thing. It shows why ergonomic design for persons with under extremity disabilities to stand up and sit is needed. Second, with further study based on the results of usability test of the disabled, it will make contribution to increase the quality of people with disabilities by helping them move and do daily lives on their own.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Development of Feed-forward AGC using Adaptive Control Algorithm (적응기법을 이용한 Feed-forward AGC 기술 개발)

  • 홍성철;이영교
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.168-171
    • /
    • 2003
  • Generally RF AGC (Roll Force Automatic Gauge Control) controls the roll gap using the variation of rolling force caused by the roll eccentricity and the entry thickness of material, but RE AGC takes the bad effect of the roll eccentricity. The Feed-forward (FF) AGC method, which controls the next stand roll gap by the estimation of the thickness variation due to skid mark is needed to supplement the shortage of RF AGC. In this paper, an adaptive filtering method which takes account of the kind of material, the final objective thickness and the rolling speed is proposed to predict skid mark thickness variation. In addition, an improved estimation method of control point using a speedometer and looper angle is suggested. Via on line test, the performance improvement of the suggested FF AGC method is verified.

  • PDF

Analysis of Working Capacity of a Hand-fed Transplanter (반자동정식기 작업 성능 분석)

  • 문성동;민영봉;박중춘
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.159-167
    • /
    • 1997
  • To cope with the mass-production and supply of plug seedling, the supply of transplanters is necessary. In the study, a transplanting test was carried out to find the optimum working condition in the mechanizd transplantation and to acquire the basic data for the improvement of transplanters by the research and analysis of working capacity of the local manual transplanters. The size of hopper affected transplanting stand and rate. Re-irrigation was required for the transplanted seedlings because they wilt 1 day after the transplanting if soil compaction is incomplete. Consequently, back-forth-left-right compaction method was good for soil covering and compaction. It may be thought to increase the amount of irrigation water at the time of transplanting by double-irrigation mechanism, but it needs to increase the larger water tank which makes the operation uneasy. So, assuming the working model by 1 or 2 operators with the machine size as small as possible, it seemed that eliminating of automatic irrigation method was desirable in view of efficiency. Though semiautomatic transplanter needs some structural improvements, it seemed still suitable for transplanting of plug seedlings such as 45-day red pepper seedlings in 128-hole tray and 25-day Chinese cabbage seedling in 128-hole tray. If traveling speed of the transplanter is limited to less than 14 m/min, with the transplanting depth of 2~3cm and transplanting space of 30cm.

  • PDF