• 제목/요약/키워드: Automatic switch

검색결과 119건 처리시간 0.025초

고속 전환특성을 가진 자동부하전환 개폐기의 구동메커니즘의 동적 해석 (Dynamic Analysis of Driving Mechanism for ALTS with High-Speed Transfer Characteristics)

  • 정원선;권병희;안길영;오일성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1530-1535
    • /
    • 2003
  • The automatic load transfer switch (ALTS) typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In this paper we build a dynamic model of driving mechanism for ALTS using ADAMS and checked the characteristics of the transfer operation. Finally we performed a detailed design of the driving mechanism through results of analysis and confirmed it to satisfy design requirements.

  • PDF

루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구 (A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop)

  • 진영택;이승재;최면송;임성일;김태완
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.

AMR과 DAS의 인터페이스 구현 (Interface design Between AMR and DAS)

  • 정점수;이흥호
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.126-133
    • /
    • 2008
  • 본 논문에서는 IT 기술기반의 통신 및 컴퓨터를 이용하여 약 $20{\sim}30[km]$ 떨어진 곳에 설치된 자동화 개폐기, 리클로져를 원격으로 제어, 감시, 계측하고 있는 DAS와 고압수용가의 원격검침, 요금 등의 업무를 수행하는 AMR과의 인터페이스를 구현하여 배전선로의 전체 고장 중 16[%]를 차지하는 고압수용가 구내 전기설비 고장에 의한 배전선로 파급고장에 대해 신속하고 정확하게 찾을 수 있는 방법을 제시하기 위해 DAS와 AMR의 인터페이스를 구현하는 것이다.

Reed Switch 센서를 이용한 원격 검침용 상수도 계량기에서 Chattering 오차 감소 방안 연구 (Reduction Chattering Error of Reed Switch Sensor for Remote Measurement of Water Meter)

  • ;권종원;박용만;구상준;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.377-379
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors used for automatic remote measurement of water supply system, a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used in measurement application by detecting the rotational or translational displacement. To apply for flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just installed simply on the mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor, two steel leaf springs make mechanical contact and apart as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But it occurs data difference or errors by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing car near to the switch sensor installed location. In order to reduce chattering error, most system uses just software methods for example using filter and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical hysteresis characteristics.

  • PDF

고 신뢰성 ATS 개발에 관한 연구 (Researches for the Development of High Reliable ATS)

  • 양오;김민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2883-2885
    • /
    • 2000
  • ATS(Automatic Transfer Switch), the secondary power supply system prepared for' temporary power fail on main in KEPCO in industrial field or running a important system. is developed. In this development, we prove that the proposed system is safe with results in a few environment testing focused on a solution against a poor environment by making virtual environment for a solution on problems of system reliability to switch more safely.

  • PDF

전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구 (A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway)

  • 허재선;강병욱;신희상;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

An Algorithm on Optimal Placement Decision of Automatic Switches for 6 Sections/3 Links Configuration in DAS

  • Lim, Il-Hyung;Zhang, Wen-Hao;Trirohadi, Hamsyah;Choi, Myeon-Song;Lee, Seung-Jae;Ha, Bok-Nam
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.328-333
    • /
    • 2011
  • A Distribution Automation System (DAS) is operated by monitoring and control of the field statesusing Feeder Remote Terminal Units (FRTUs) installed together withautomatic switches.An optimal placement of automatic switchescan enhanceefficiencyof the operation and restoration, and improve the power supply reliability ofa DAS.This paper proposes an algorithm to decide the optimal placement of automatic switches ina DAS.The proposed algorithm was developed ona DAS witha six sections and three links configuration. The proposed algorithm was provided inaneight-feeder power distribution system.

정압비례제어방식을 적용한 정압급수장치의 개발 (Development of a constant pressure feed system using a constant pressure proportional control mode)

  • 김주명;김광열;이건기
    • 한국정보통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.1026-1031
    • /
    • 2003
  • 자동 급수펌프는 압력스위치에 의해 운전 및 정지를 하게 된다. 따라서 수량 증감에 따른 펌프의 빈번한 운전 및 정지로 인해 지속적인 정격 및 정압 운전이 불가능하다. 또한 빈번한 작동으로 인해 지속적으로 일정한 압력을 얻을 수 없으며, 펌프의 소손과 에너지의 낭비가 심한 단점을 가지고 있다. 본 논문에서는 이러한 단점을 해결하고자 급수밸브, 유량센서, 제어장치로 구성되는 정압 급수장치를 설계 제작하였다. 급수밸브는 유출되는 물의 양과 관계없이 항상 일정한 양의 물을 유입하여 펌프의 부하를 줄이는 역할을 한다. 유량센서는 적외선 다이오드를 사용하여 유출되는 물의 양의 측정하며, 제어장치는 8 비트 마이크로프로세서를 이용하여 설계하였으며, 특별한 제어 알고리듬에 의해 펌프의 운전과 정지를 제어하게 하였다. 본 논문에서 개발한 장치는 토출 압력이 일정하게 유지되고 펌프의 작동 및 정지 동작이 부드럽게 이루어지며, 펌프의 지속적인 정압운전이 가능하므로 기존의 단점을 보완하는 장치로 사료된다.

리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구 (Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter)

  • ;김희식
    • 전자공학회논문지SC
    • /
    • 제44권4호통권316호
    • /
    • pp.42-47
    • /
    • 2007
  • 상수도 원격 검침에서는 리드 스위치의 채터링 오차를 감소시키기 위한 센서 연구 및 개선이 필요하다. 센서의 동작은 전기적 펄스를 발생시키기 위한 영구 자석 주각의 접근에 의한 기계적 접촉스위치처럼 나타낼 수 있다. 대부분 회전 또는 전달 이동을 잡기 위해 사용되고 수류 측정 장치에 적용하기 위해서는 높은 신뢰성이 필수이다. 동작 형태를 간단히 설명하게 되면 미터기 작동 모터 끝에 달려있는 작은 자석이 미터기 회전에 의해 리드 스위치 내부에 있는 두 개의 스프링과 기계적 접촉 형식으로 반복적으로 떨어지게 된다. 즉 수류량에 따라 펄스의 수가 증가하는 것이다. 이렇게 측정된 값은 무선 이동 통신을 통해 서버로 전달되게 된다. 문제는 자석과 리드 스위치가 만나는 지점에서 스위치가 멈추게 되면 떨리면서 펄스가 잘못 올라가는 오차가 생기는 것이다. 이러한 오차를 감소시키기 위해 보통 소프트웨어적인 방법을 사용한다. 필터 알고리듬을 사용하는것과 통계적인 보정방법을 사용하는 것이 그러한 예이다. 하지만 그러한 방법보다는 하드웨어적으로 문제를 해결하는 것이 오차를 줄일 수 있는 더 직접적인 방법이다. 본 논문에서는 기계적인 이력현상의 특성을 이용하여 리프 스프링 구조의 변화로 오차를 감소시키는 연구를 수행하였다.