• Title/Summary/Keyword: Automatic equipments

Search Result 157, Processing Time 0.024 seconds

New deep mixing method installed automatic control equipments (자동제어장치가 장착된 최첨단 심층혼합고결처리공법에 관한 연구)

  • 한우선;조기호;임우성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.847-852
    • /
    • 2003
  • The purpose of this paper is to develop the new deep mixing method installed automatic control equipments for the better construction in deep mixing and grouting. Civil, geotechnical, electronic, and communication experts have worked together for a long time for the development of automatic measuring devices using wire and wireless transmitting-receiving set. A series of laboratory and field experiments were carried out to check the reliability and field applicability of this system. New total automatic control system including automatic devices for checking angle, depth and quantity of injected grout was invented from the result of this research.

  • PDF

The Automatic equipments Non-Exposure waterproofing method of reduced construction hours integrated with the improved URE-Sheet and UREPALT adhesives (우레팔트 접착제를 사용한 개량형 우레시트 일체식 공기단축형 기계화 시공 비노출 방수공법)

  • Min, Sung-Woo;Oh, Chang-Won;Yang, Jae-Bong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.135-141
    • /
    • 2009
  • This technology is able to construct with hardening UREPALT adhesives and TPO URE-Sheet simultaneously using automatic equipments. the benefit of this construction method is that The layer of waterproofing is uniform and defect of construction would be reduced because of no construction joints between UREPALT adhesives and TPO URE-Sheet. Furthermore, this new method could accomplish shortening of construction period, quality control and saving of labor costs. Also the non-exposure waterproofing method would be protected from fire and safe for workers without using a torch.

  • PDF

Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave (소리의 방향성 측정을 위한 실험기기의 자동제어)

  • Jarang, Sun-Suck;Ko, Jae-Ha;Lee, Je-Hyeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

The study of Line - frequency Control in performance improvement of plant Control system. (계통주파수 제어를 위한 발전제어 특성개선)

  • Hur, Sung-Khang;Song, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.114-117
    • /
    • 1987
  • This study is concerned with the improvement of the Automatic Boiler Control and Turbine Governor system to maintain line - frequency within $60{\pm}0.1\;HZ$. This describes the current problems of plant control system, the method, and equipments to be developed for each plant based on the experimental test were carried out at field, and, lastly, the results of the study with the progress of it.

  • PDF

Auto packer with pneumatic equipment (공압을 이용한 자동포장장치)

  • 김장호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.335-339
    • /
    • 1987
  • In this report, automatic packing equipment for dairy milk is presented. For food industry, Pneumatic System is widely applied because of it's environments. So, for the actuation, signal processing and sensing of this auto-packer, all pneumatic equipments was applied.

  • PDF

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

The Development of the Automatic Operation System for the Laboratories Equipment based on MATLAB GUI (MATLAB GUI 기반의 실험·실습실 자동화 운용 시스템 개발)

  • Wee, Sang-Bong;Park, Ji-Hong
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.2
    • /
    • pp.158-161
    • /
    • 2012
  • Wee developed the automatic operation system for the laboratories equipment based on MATLAB GUI. By using Instrument Control Tool Box and standard protcol, PC and equipments are well connected each other. Wee developed the software to control the display of input and output between PC and equipments by using MATLAB GUI, This system will be effectively used in laboratories and experimental facilities and more in on-line education system for experiments.

  • PDF

A Study on the Analysis of Errors occurred by Different Type of Automatic Bacteria Counting Equipments used in Counting Bacterial Number of Raw Milk (우유의 세균 자동측정장치의 오차범위 조사 및 오차발생 요인 분석에 관한 연구)

  • 정충일;엄양섭;김광태;강국희;이수원
    • Food Science of Animal Resources
    • /
    • v.21 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • This study was conducted to analyze the errors occurred between standard plate count(SPC) and Bactometer, Malthus, Bactoscan and to investigate correlation coefficient(r) between SPC and each equipments for the purpose of making new calibration curve. Correlation coefficients of three different types of equipments to SPC value were 0.71, 0.81, 0.84 respectively(n=287) and that of three types of equipments were 0.71∼0.82 relatively low. In raw milk, correlation coefficients of three types of equipments of SPC were in the range of 0.67∼0.73 below 3.0${\times}10^4$(CUF/ml) of bacterial number, and those between the three types of equipments were 0.68∼0.72. Between 3.0${\times}10^4$∼5.0${\times}10^5$(CFU/ml) of bacterial number, correlation coefficients of the three different types of equipments were 0.71∼0.81. and those between the three different types of equipments were 0.64∼0.77. Over 5.0${\times}10^5$(CFU/ml), correlation coefficient of the three types equipments were 0.66∼0.83 and those between them were 0.70∼0.85 respectively. The error of the three different types equipments to SPC value was significantly high, 37∼53% of them was under 50% of error range, and in case of raw milk less than 3.0${\times}10^4$ of bacterial number, 44∼67% of them showed over 100% of error.

  • PDF

A Study on Development and Utilization of Automatic Parking Survey System (자동주차조사 시스템 개발 및 활용에 관한 연구)

  • Lee, Young Woo;Kwon, Hyuck Jun
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.452-461
    • /
    • 2014
  • Conventional parking survey has been usually performed by a person, which has a lot of problems such as decreased mobility, data input error, longer time and expensiveness. Therefore, this study attempted to develop an automatic parking survey method using lately commercialized equipments that were highly efficient imagery interpretation equipments, GPS, and infrared lighting fixtures. In addition, this study developed a parking analysis software that enables to modify and save data, and analyze survey data by the automatic parking survey method. When parking survey is conducted using automatic parking survey method, surveying accuracy is influenced by the running speed of a surveying vehicle, the photographing angle of an imagery interpretation equipment, the gap between parking vehicles and the distance of a surveying vehicle to parking vehicles. Therefore, this study drew optimum conditions by testing on each items for accuracy improvement, and developed a parking analysis software for systematic storage and management of parking survey data, supporting the parking analysis and output the parking analysis result.