• Title/Summary/Keyword: Automatic Setting

Search Result 186, Processing Time 0.028 seconds

Implementation of Context-Aware Android Application for Automatic Task Setting (상황 인지 기반의 자동 태스크 설정을 위한 안드로이드 어플리케이션 구현)

  • Bak, Na-Yeon;Chung, Da-hae;Chang, Byeong-Mo;Choi, Kwanghoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.434-443
    • /
    • 2016
  • Users can set manually Android phone to do particular tasks on some situations. This type of setting is inconvenient, and also provide with unnecessary services, which don't consider users' situation. In this research, we design and implement a context-aware automatic task setting application. Users can get context-aware service by setting desired tasks based on contexts using this system. We design a language for describing context-action rules, and statically check validity of context-action rules by performing syntax and semantic check.

Sweeping Center Setting Automation for Wavelength Swept Laser used in SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 스위핑 중심 세팅 자동화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2017
  • In this paper, the automation of sweeping center setting for wavelength swept laser used in SS-OCT has implemented. For 3 regions where the initial FFP-TF pass wavelength can be located, each different DC voltage pattern is applied to FFP-TF. Through its performance test to the laser, fast and exact setting to sweeping central wavelength, flat sweeping with ${\pm}0.5dB$ fluctuation range, and 10 mW average optical power were obtained. This shows that the realized automatic setting process can replace an inconvenient manual setting operation used for current wavelength swept laser. Additionally it cuts costs for optical spectrum analyzer necessary to laser spectrum monitoring.

PROSET2000 : An Integrated Computer Program for Power Transmission System Protection (PROSET2000 : 송전계통 보호 전산종합 프로그램 개발)

  • Kim, Yeong-Il;Lee, Seung-Jae;Choe, Myeon-Song;Gang, Sang-Hui;Kim, Ho-Pyo;Lee, Un-Hui;Choe, Hong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.538-544
    • /
    • 1999
  • One of the most important requirements for the development of computerized relay setting system is its openness to abbommodate the various changes like new panel additions. This paper describes the relay settein-coordination system(PROSET2000), which has an open system architecture and adopts the dbject oriented programming paradigm. Its main features include the intelligent fault type identification, automatic running of the short circuit analysis, ren-time rulebase modification, automatic documentation, ect.

  • PDF

A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop (루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구)

  • Jin, Young-Taek;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Seong-Il;Kim, Wan-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.

Assessment of Early-age Properties of Mortar by Monitoring of Ultrasonic Pulse Velocity (초음파 속도 모니터링에 의한 모르터의 초기재령 특성 평가)

  • 이회근;이광명
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.245-250
    • /
    • 2001
  • Ultrasonic pulse velocity(UPV) is a useful tool for examining the property of early-age mortar or concrete. Thus, UPV has been used for a long time to characterize setting and hardening of cementitious materials. In this study, in order to investigate the characteristics of setting for mortar, UPV was measured using automatic monitoring system up to 3 days after casting. Test results show that UPV of high water to binder ratio(w/b) mortar remained constant at the beginning of hydration and then abruptly began to increase. However, UPV of low w/b mortar gradually increase due to setting retard caused by use of superplasticizer. Furthermore, the development of UPV for mortar with fly ash is slower than that of mortar without fly ash. It was concluded that the property change of mortar or concrete, such as setting and hardening can be assessed by monitoring of UPV.

  • PDF

An Automatic Portscan Detection System with Adaptive Threshold Setting

  • Kim, Sang-Kon;Lee, Seung-Ho;Seo, Seung-Woo
    • Journal of Communications and Networks
    • /
    • v.12 no.1
    • /
    • pp.74-85
    • /
    • 2010
  • For the purpose of compromising hosts, attackers including infected hosts initially perform a portscan using IP addresses in order to find vulnerable hosts. Considerable research related to portscan detection has been done and many algorithms have been proposed and implemented in the network intrusion detection system (NIDS). In order to distinguish portscanners from remote hosts, most portscan detection algorithms use a fixed threshold that is manually managed by the network manager. Because the threshold is a constant, even though the network environment or the characteristics of traffic can change, many false positives and false negatives are generated by NIDS. This reduces the efficiency of NIDS and imposes a high processing burden on a network management system (NMS). In this paper, in order to address this problem, we propose an automatic portscan detection system using an fast increase slow decrease (FISD) scheme, that will automatically and adaptively set the threshold based on statistical data for traffic during prior time periods. In particular, we focus on reducing false positives rather than false negatives, while the threshold is adaptively set within a range between minimum and maximum values. We also propose a new portscan detection algorithm, rate of increase in the number of failed connection request (RINF), which is much more suitable for our system and shows better performance than other existing algorithms. In terms of the implementation, we compare our scheme with other two simple threshold estimation methods for an adaptive threshold setting scheme. Also, we compare our detection algorithm with other three existing approaches for portscan detection using a real traffic trace. In summary, we show that FISD results in less false positives than other schemes and RINF can fast and accurately detect portscanners. We also show that the proposed system, including our scheme and algorithm, provides good performance in terms of the rate of false positives.

Risk of High Temperatures on Rice Production in China: Observation, Simulation and Prediction

  • Tao, Fulu;Shi, Wenjiao
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2016.09a
    • /
    • pp.44-48
    • /
    • 2016
  • Extreme temperature impacts on field crop are of key concern and increasingly assessed, however the studies have seldom taken into account the automatic adaptations such as shifts in planting dates, phenological dynamics and cultivars. In this present study, trial data on rice phenology, agro-meteorological hazards and yields during 1981-2009 at 120 national agro-meteorological experiment stations were used. The detailed data provide us a unique opportunity to quantify extreme temperature impacts on rice yield more precisely and in a setting with automatic adaptations.

  • PDF

A Study for the Automatic Control System in Greenhouse Using Microcomputer(IV) -Application of a Controller for the Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 연구(IV) -자동화 시스템용 종합제어기의 응용-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.288-298
    • /
    • 1995
  • In greenhouse vegetable, the automatic control in cultivating environment has been projected as a national business ; especially a countermeasure against the settlement of UR negotiation. Because it makes possible to manage a large greenhouse with family-hands and to expect the betterment of quality and the increasement of harvest in crops. In the course of carrying the workout, however, there are many problems with the overall control system with computers as well as the individual systems for environment control because of hardware and software problems : especially the shortage of data for development of the system is most serious. Among the many problems for development of the automatic control system, the automations of irrigation, liquefied fertilizer and chemical solution, mixing and ventilation, etc and the development of the general automatic controller system for environment control in greenhouse are studied, which requires a lot of tabors. The results are summarized as follows ; 1. In moisture control by the soil moisture meter, the error was shown 10 % in the beginning irrigation point and 19 % in the stop irrigation point. 2. The supply of liquefied fertilizers with the irrigation system was excellent by setting the operating time and the mixing ratio. 3. The developed chemical spraying system was operated well, but not perfect in nozzle positions. 4. The cucumber was cultivated properly with the trickle irrigation system. 5. The developed controller for the automatic control system in greenhouse was remarkable in the part of hardware, but more researches are needed in the part of software.

  • PDF

Study on Automatic Generation of Platform Configuration Register in FlexRay Protocol (FlexRay 프로토콜에서 플랫폼 구성 변수의 자동 생성에 관한 연구)

  • Yang, Jae-Sung;Park, Jee-Hun;Lee, Suk;Lee, Kyung-Chang;Choi, GwangHo
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Recently, FlexRay was developed to replace controller area network (CAN) protocol in chassis networking systems, to remedy the shortage of transmission capacity and unsatisfactory real-time transmission delay of conventional CAN. FlexRay network systems require correct synchronization and complex scheduling parameters. However, because platform configuration register (PCR) setting and message scheduling is complex and bothersome task, FlexRay is more difficult to implement in applications than CAN protocol. To assist a network designer for implementing FlexRay cluster, this paper presents an analysis of FlexRay platform configuration register and automatic generation program of PCR. To demonstrate the feasibility of the automatic generation program, we evaluated its performance using experimental testbed.

Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device (액제 정밀계량장치를 이용한 액제 자동조제 시스템개발)

  • 류관희;홍순호;이규철;이정훈;황호준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.06c
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF