• Title/Summary/Keyword: Automatic Mixing System

Search Result 36, Processing Time 0.024 seconds

New deep mixing method installed automatic control equipments (자동제어장치가 장착된 최첨단 심층혼합고결처리공법에 관한 연구)

  • 한우선;조기호;임우성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.847-852
    • /
    • 2003
  • The purpose of this paper is to develop the new deep mixing method installed automatic control equipments for the better construction in deep mixing and grouting. Civil, geotechnical, electronic, and communication experts have worked together for a long time for the development of automatic measuring devices using wire and wireless transmitting-receiving set. A series of laboratory and field experiments were carried out to check the reliability and field applicability of this system. New total automatic control system including automatic devices for checking angle, depth and quantity of injected grout was invented from the result of this research.

  • PDF

Design and Implementation of an Automatic System for Mixing Offset Ink (인쇄용 옵셋 잉크 자동 교반시스템의 설계 및 구현)

  • Choi, Sung-Hac;Lee, Joon-Yeol;Lee, Bong-Su;Lee, Sang-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.545-553
    • /
    • 2012
  • This paper reports the development of an automatic system for mixing offset printing ink. The ink mixing process is important in industrial fields where paint and ink are used. In particular, there is a demand for automating the process of producing spot colors, which involves mixing a small quantity of high-viscosity ink. The authors designed, fabricated, and experimentally tested an automatic mixing system that employs the revolution and rotation of ink and the transmission by belts. The performance of the ink mixing system was verified by conducting numerous experiments to determine the effect of rotation direction, speed, ink container axis angle, and ink amount. Conditions suitable for mixing offset ink are presented for use as guidelines for producing spot colors.

A Study for the Automatic Control System in Greenhouse Using Microcomputer(IV) -Application of a Controller for the Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 연구(IV) -자동화 시스템용 종합제어기의 응용-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.288-298
    • /
    • 1995
  • In greenhouse vegetable, the automatic control in cultivating environment has been projected as a national business ; especially a countermeasure against the settlement of UR negotiation. Because it makes possible to manage a large greenhouse with family-hands and to expect the betterment of quality and the increasement of harvest in crops. In the course of carrying the workout, however, there are many problems with the overall control system with computers as well as the individual systems for environment control because of hardware and software problems : especially the shortage of data for development of the system is most serious. Among the many problems for development of the automatic control system, the automations of irrigation, liquefied fertilizer and chemical solution, mixing and ventilation, etc and the development of the general automatic controller system for environment control in greenhouse are studied, which requires a lot of tabors. The results are summarized as follows ; 1. In moisture control by the soil moisture meter, the error was shown 10 % in the beginning irrigation point and 19 % in the stop irrigation point. 2. The supply of liquefied fertilizers with the irrigation system was excellent by setting the operating time and the mixing ratio. 3. The developed chemical spraying system was operated well, but not perfect in nozzle positions. 4. The cucumber was cultivated properly with the trickle irrigation system. 5. The developed controller for the automatic control system in greenhouse was remarkable in the part of hardware, but more researches are needed in the part of software.

  • PDF

Study on Automatic Mixing of Nutrient Solution Using ion Electrodes for Closed-Loop Hydroponics (이온전극을 이용한 순환식 양액 자동 조제에 관한 연구)

  • 김민규;류관희;장유섭;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.425-432
    • /
    • 2002
  • This study was carried out to develop an automatic mixing system of nutrient solution for closed-loop hydroponics using ion electrodes. The results of the study are summarized as follows: 1. It appeared that ion-electrodes had not to be soaked into nutrient solution for a long time since it was much less durable than EC or PH sensors. Once ion-electrodes were soaked into real nutrient solution for a long time, they became unstable. 2. ion measurement modules, which were able to sample recirculated nutrient solution and easily wash and dry ion-electrodes, were developed in order to use ion-electrodes continuously. 3. The results of calibration tests on three kinds of ion electrodes presented that the time required to read measurement data was over 30 seconds. Using the calibration data the regression equations for the ion electrodes were developed. 4. An automatic nutrient-solution mixing system using the three kinds of ion electrodes was developed and then its accuracy was examined. The control errors of the mixing system using ion electrodes were in the range of 9.8 to 12%.

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control (퍼지제어를 이용한 양액 자동공급 시스템 개발)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF