• Title/Summary/Keyword: Automatic Measurement System

Search Result 610, Processing Time 0.027 seconds

The Development of 3D based On-Machine Measurement Operating System (3D 기반의 기상측정 운영시스템 개발)

  • 윤길상;최진화;조명우;김찬우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.145-152
    • /
    • 2004
  • This paper proposed efficient manufacturing system using the OMM (on-machine measurement) system. The OMM system is software based 3D modeler for inspection on machine and it is interfaced tool machine with RS232C. The software is composed of two inspection modules that one is touch probe operating module and the other is laser displacement sensor operating module. The module for touch probe has need of inspection feature that extracted it from CAD data. Touch probe moves to workpiece by three operating modes as follows: manual, general and automatic mode. The operating module of laser displacement sensor is used inspection for profile and very small hole. An Advantage of this inspection method is to be able to execute on-line inspection during machining or after it. The efficiency of proposed system which can predict and definite the machining errors of each process is verified, so the developed system is applied to inspect the mold-base(cavity, core).

An Automatic AC-DC Transfer Error Measurement System (교류-직류 변환오차 자동 측정시스템)

  • Kwon, Sung-Won;Cho, Y.M.;Kim, K.T.;Kang, J.H.;Park, Y.T.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.401-408
    • /
    • 1998
  • A dual-channel automatic ac-dc voltage transfer error measurement system in which the output voltages of two thermal voltage converters which are ac voltage standard are directly measured at the same time to reduce the output voltage drift is described. Forward-reverse measurement method by using a two-channel scanner is used to cancel the offset voltage of the voltmeters. The agreements of the 4-V TVC comparison results between other national standards institute and Korea Research Institute of Standards and Science were less than about ${\pm}2\;ppm$ in the frequency range of $40\;Hz{\sim}100\;kHz$, and were less than about ${\pm}4\;ppm$ at $200\;kHz{\sim}1\;MHz$. Measurement uncertainty is reduced significantly from ${\pm}4\;ppm$ of manual system to ${\pm}3\;ppm$ of new system(up to 100 kHz) typically and great increase in comparison efficiency has been achieved by this system.

  • PDF

Development of Automatic Displacement Measuring System Using 3D Digital Photogrammetry Image and Its Application (수치사진영상을 이용한 자동 변위계측시스템의 개발과 적용)

  • Han, Jung-Geun;Kim, Young-Seok;Cho, Sam-Duk;Kwak, Ki-Seok;Hong, Ki-Kwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.53-62
    • /
    • 2007
  • Recently, for the stabilization estimation of structures, many automatic measuring instruments with expensiveness and high accuracy have been developed and utilized. However, the existing manual measuring systems are almost impossible to measure the real-time for the whole surface of large-scale structures and an automatic measuring system has disadvantages with demanding enormous expense. In this study, 3D digital visual monitoring system was developed by using digital photogrammetry technique. To confirm application of developed system, it was applied to the measurement of the wall displacement of concrete surface and displacement measurement of reinforced-soil wall block. Then, the result of the test was compared with measuring value of total station. Based on the results of the comparison, the application of visual monitoring system was evaluated. The results show that the developed visual monitoring system could be available in displacement measure of structures.

A Study on the Evaluation of Long Term Stability of Brinell Standard Hardness Tester and Automatic Indentation Measurement System and Optimum Test Condition (브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung;Hwang, N.M.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.10-15
    • /
    • 2000
  • Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is $30{\mu}m/s$ of load application speed and 25 seconds of load application time.

  • PDF

Evaluation of Impedance on Biological Tissues Using Automatic Control Measurement System (자동제어 측정 시스템을 이용한 생체 조직의 임피던스 평가)

  • Kil, Sang-Hyeong;Lee, Moo-Seok;Kim, Sang-Sik;Shin, Dong-Hoon;Lee, Seong-Mo;Kim, Gun-do;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.239-244
    • /
    • 2015
  • Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection aganinst radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biblogical tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed. automatic control system.

Automatic Extraction of Particle Streaks for 3D Flow Measurement

  • Kawasue, Kikuhito;Ohya, Yuichiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.270-273
    • /
    • 1999
  • Circular dynamic stereo has special advantages as it enables a 3-D measurement using a single TV camera and also enables a high accurate measurement without a cumbersome calibration. Annular particle streaks are recorded using this system and the size of annular streaks directly concerns to the depth from TV camera. That is, the size of annular streaks is inversely proportional to the depth from the TV camera and the depth can be measured automatically by image processing technique. Overlapped streaks can be processed also by our method. The flow measurement in a water tank is one of the applications of our system. Tracer particles are introduced into the water in a flow measurement. Since the tracer particles flow with water, three-dimensional velocity distributions in the water tank can be obtained by measuring the all movement of tracer particles. Experimental results demonstrate the feasibility of our method.

  • PDF

Net Ecosystem Productivity Determined by Continuous Measurement Using Automatic Sliding Canopy Chamber

  • Kim, Gun-Yeob;Lee, Seul-Bi;Lee, Jong-Sik;Choi, Eun-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1179-1186
    • /
    • 2012
  • For better understanding of carbon cycle dynamics of an agro-ecosystem, an accurate assessment of seasonal and daily $CO_2$ flux is essential to understand the relationship between various environmental factors and crop productivity. We developed the automatic sliding canopy chamber (ASCC) system that measured continuous net ecosystem productivity (NEP) over whole growing season under the natural meteorological rhythm. The ASCC was composed of two main parts which were sliding part for measuring NEP, and automatic opening and closing chamber (AOCC) for measuring soil respiration (SR) on the soil surface. The ASCC was developed by using open flow method for measuring soil $CO_2$ efflux. The disturbance of natural meteorological condition was minimized by opening the base frames. In the field test with barley (Hordeum vulgare L.), NEP was calculated at $140mg\;CO_2\;m^{-2}h^{-1}$ on a clear day using continuous data and eliminated the possibility of overestimate about 16% using one hour data during the day time. Unlike other small scale chamber system, installation on cropping-field made it possible to take any modifications which might be caused by natural environmental condition.

A Study on the Automatic Measurement of Salt Contamination (염분 오손 자동측정에 관한 연구)

  • Kwak, Hee-Ro;Kim, Han-Sang;Kweon, Dong-Jin;Lee, Dong-Zoon;Kim, Kyoung-Wha;Cho, Kug-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1362-1364
    • /
    • 1995
  • In this paper, the automatic device for measuring the salt contamination on insulators was developed. The device consists of electronic insulators, measuring system, monitoring system, and printer. It was shown that the level of salt contamination measured by the developed device is similar to that measured by the brush cleaning method. Therefore, the developed automatic measuring device can be used in field, in order to predict the cleaning time of insulators and prevent the failure due to the salt contamination.

  • PDF

Automatic Inspection of Assembly Tolerances of Cathod Ray Electron Guns by Vision Probe (비젼프로브를 이용한 CRT 전자총의 자동치수 검사)

  • Park, H.G.;Park, M.C.;Kim, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.28-34
    • /
    • 1997
  • This paper describes an automatic measurement method for the in-line inspection of assembly tolerances of cathod ray electron guns. The method uses an optical microscope with a CCD camera as a probe. An automatic gap recognition algorthm with digital image processing and a new software autofocus algorithm based on using an optimal edge detector have been developed to improve the measuring accuracy. An inspection system has been proposed and practically implemented for in-line inspection to a real factory automation line. The inspection system consists of a gap inspection part and an eyelet. Total time consumed for inspecting all measuring items is about 10 seconds and the repeatability is below .+-. 5 .mu. m

  • PDF

Statistical Prediction of False Alarm Rates in Automatic Vision Inspection System (자동결함 검출시스템에서 결함크기 측정오차로 인한 오검률의 통계적 예측)

  • Joo, Young-Bok;Huh, Kyung-Moo;Park, Kil-Houm
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.9
    • /
    • pp.906-908
    • /
    • 2009
  • AVI (Automatic Vision Inspection) systems automatically detect defect features and measure their sizes via camera vision. It is important to predict the performance of an AVI to meet customer's specification in advance. Also the prediction can indicate the level of current performance of an AVI system. In this paper, we propose a statistical method for prediction of false alarm rate regarding inconsistency of defect size measurement process. For this purpose, only simple experiments are needed to measure the defect sizes for certain number of times. The statistical features from the experiment are utilized in the prediction process. Therefore, the proposed method is swift and easy to implement and use. The experiment shows a close prediction compared to manual inspection results.