• 제목/요약/키워드: Automatic Alarm System

검색결과 115건 처리시간 0.022초

클린룸 자동화재탐지설비의 성능위주 방재설계 적용에 관한 고찰 (A Study on the appliance of performance based design to the automatic fire alarm system in clean room facility)

  • 김동성;황철승;이상곤;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.513-517
    • /
    • 2007
  • This study is to establish the appliance model for the automatic fire alarm system in clean room within the framework of the performance based design. Because of the environmental and dimensional characters of clean room, this space is exposed to fire and toxic damage, so it is very important to notify the occupants of these dangerous situations.

  • PDF

Establishment of Alarm Criteria for Automatic Water Quality Monitoring System in Korea

  • Lim, Byung-Jin;Hong, Eun-Young;Kim, Hyun-Ook;Jeong, Eun-Sook;Heo, Woo-Myung;Kim, Yoon-Hee
    • 생태와환경
    • /
    • 제41권4호
    • /
    • pp.423-430
    • /
    • 2008
  • As of September 2008,45 Automatic Water Quality Monitoring Systems (AWQMS) have been installed at different sites on the 4 rivers to detect early the presence of pollutants in water and to issue an alarm. We count the number of issuing alarms by AWQMS, however, we will find the alarm has hardly been issued. The reasons for the scarcity of alarm issue are extensively being examined. The National Institute of Environmental Research attributes wrong alarm criteria for each AWQMS station to one the reasons. In this study, a suggestion has been made to modify the current alarm criteria to correspond with characteristics of river water quality. The current system with only two criteria (low and high) should be replaced as four-criteria systems (low, medium, high, and severe) based on cases of other advanced countries and stream conditions of Korea. The highest value of data collected for 5 years was suggested as the alarm criteria for each parameter. Meanwhile the alarm criteria for VOCs, phenol and heavy metals were established as same as drinking water quality criteria.

재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선 (Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver)

  • 지승욱;김시국;양승현;이재진;김필영;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

자동화재탐지설비의 신뢰성 개선에 관한 연구 (Research on the Reliability Improvement of Automatic Fire Alarm System)

  • 손영진;이영일;이상현
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.42-49
    • /
    • 2008
  • 본 연구에서는 기존의 자동화재탐지설비의 오동작(비화재보, 실보)과 빈번한 오동작으로 인한 전원의 차단 등의 문제점을 해결하고 보다 높은 신뢰성을 갖는 자동화재탐지설비를 구성하기 위한 방안을 제시한다. 제안된 방식은 다중센서를 이용한 마이크로프로세서-기반의 디지털 제어시스템으로서 화재 시 발생되는 여러 가지 연소생성물을 감지하기 위해서 열, 연기, CO 센서 등을 복합적으로 사용한다. 이와 같은 방식에 따라 자동화재탐지설비의 오동작 발생 가능성을 줄인 화재감지시스템을 구성하였고, 다중센서 화재감지장치의 화재 감지 및 판별 알고리즘에 의해서 화재발생의 여부를 디지털 제어시스템에 의해서 신뢰도 높게 판단함을 실제 시험을 통해 검증하였다. 실제 화재감지시스템을 구성하였고, 화재시험을 통해서 제안 된 방식의 향상된 신뢰도를 검증하였다.

화재감지기의 오보 감소를 위한 구조 신뢰도 분석 (Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms)

  • 김주홍;임현교
    • 한국안전학회지
    • /
    • 제8권1호
    • /
    • pp.6-12
    • /
    • 1993
  • Now it is reported that there are many companies and factories which confront to the problem of false alarm in Automatic Fire Detecting System (AFDS). Though an AFDS is a high-priced and very important device in detecting a fire. the problem degrades the reliability and utility, eventually faith. of the system. This is a research concerned about the problem of false alarm of fire detectors in an AFDS. Structure of detectors was modeled up as a general K out-of n system. and reliability characteristics including false alarm rate and missed alarm rate, are derived from it. For decision of an optimal structure of detectors. preliminary analysis on various criteria is accomplished. It is concluded that appropriate modification of a detector with plural sensors may increase the system reliability and decrease the false alarm rate.

  • PDF

자동화재 탐지설비의 비화재보 감소방안 (A Study about False Alarm of Automatic Fire Detection System)

  • 이종화;이춘하;김시국;공하성
    • 대한안전경영과학회지
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석 (Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권2호
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

가우시안 배경혼합모델을 이용한 Tracking기반 사고검지 알고리즘의 적용 및 평가 (Measuring of Effectiveness of Tracking Based Accident Detection Algorithm Using Gaussian Mixture Model)

  • 오주택;민준영
    • 한국도로학회논문집
    • /
    • 제14권3호
    • /
    • pp.77-85
    • /
    • 2012
  • 자동사고검지 알고리즘의 대부분은 사고가 발생했을 때 사고로 검지하지 못하고, 혼잡으로 검지하는 경우가 많다는 문제점을 가지고 있다. 또한 교통정보센터 운영자들은 교통사고검지시스템을 운영하면서 대부분 CCTV 육안감시 또는 운전자들의 신고에 의존하여 사고처리를 하고 있는 실정이다. 그 이유는 현재 운영되고 있는 교통사고검지시스템에서는 실제 사고가 아닌데도 불구하고, 사고라는 오검지 경고가 많이 발생되어 시스템 전체의 신뢰도가 떨어진다는 문제점이 있기 때문이다. 다시 말해 교통사고검지시스템의 알고리즘은 검지율(Detection probability)이 높아야 함과 동시에, 오검지율(False alarm probability)은 낮아야 하고, 정확한 사고지점과 시간을 검지해 낼 수 있어야 한다. 이에 본 연구는 검지율을 높이고 동시에, 오검지율을 낮추는 방법으로 기 개발된 가우시안 혼합모델(Gaussian Mixture Model)과 개별차량 Tracking을 이용하여 개발한 사고검지 알고리즘을 교통정보센터 관리시스템(Center Management System)에 적용하고, 실제 교통상황에서 사고검지율과 오검지의 빈도를 측정하여 그 효과를 검증 및 평가하고자 한다.

위험도로사면의 실시간 무인감시시스템 개발 연구 (A Study on Development of Automated Monitoring System for Road Cut Slopes)

  • 김춘식;이광우;윤수호;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.607-614
    • /
    • 2000
  • A cost-effective automated slope monitoring system is developed to monitor hazardous cut slopes along highways. This automated slope monitoring system consists of data-collection and visual monitoring, data-transmitting, database and internet service, and alarm system. Wire-line extensometer, automatic raingauge, and CCD camera are selected as monitoring instruments in this system, after consideration of failure characteristics of roadside cut slopes in the country. This paper describes the important features of this newly developed automated slope monitoring system.

  • PDF