• 제목/요약/키워드: Auto-Switching

검색결과 43건 처리시간 0.021초

Development of An Apparatus to Control Odorous Stimuli for Olfactory Evoked Responses

  • Min, Byung-Chan;Chung, S.C.;Min, S.W.;Kim, S.K.;Park, S.J.;Kim, C.J.;Shin, J.S.;Kim, J.S.;Lee, D.H.;Sakamoto, K.
    • 산업경영시스템학회지
    • /
    • 제22권53호
    • /
    • pp.69-78
    • /
    • 1999
  • We developed an apparatus for odorous stimuli control to record olfactory evoked potentials from human scalp. The characteristics of the apparatus were as follows. 1. Translating the subjects respiration into electric signals with a sensor attached to the nose. The period and timing of odorous stimuli could be adjusted, so that stimuli could be synchronous with respiration. 2. The respirations translated into electric signals were made constant in amplitude by using an auto gain control circuit. 3. The interstimulus interval of odorous could be arbitrarily selected once every 1 to 9 respirations so that adaptation could be prevented. We obtained olfactory - evoked potentials (OEPs) to odorous stimuli using this apparatus from the site of Cz, whose positive peak latencies were approximately $180{\pm}23ms$. Such response were not recorded if oxygen stimuli were used instead of odorous or with click sounds produced by the switching electromagnetic valve.

  • PDF

Development of Highly Sensitive Analytical Method for Evaluation of Evening Primrose Oil's Enhancing Effect in Prostaglandin E1(OP 1206) Biosynthesis

  • Lee, Sung-Hoon
    • 인간식물환경학회지
    • /
    • 제21권6호
    • /
    • pp.485-492
    • /
    • 2018
  • This study aimed to develop and validate highly sensitive determination method of a prostaglandin ($PGE_1$, OP 1206) in human plasma by LC-MS/MS using column switching. Plasma stored at $-30^{\circ}C$ and treated with methanol effectively inhibited interferences synthesized post-sampling. Samples were added with internal standard and were separated by reversed-phase HPLC with a cycle time of 30min. The method was selective for OP 1206 and the regression models, based on internal standard, were linear across the concentration range 0.5-50 pg/mL with the limit of quantification of 0.5 pg/mL (limit of quantitation, LOQ) for OP 1206. The calibration curve of OP 1206 standards spiked in five individual plasma samples was linear ($r^2=0.9999$). Accuracy and precision at the concentrations of 0.5, 1.5, 5.0 and 40 pg/mL, and at the lower LOQ of 0.5 pg/mL were excellent at 20%. OP120 < 6 was stable in plasma samples for at least 24 hours at room temperature, 24 hours frozen at $-70^{\circ}C$, 24 hours in an auto sampler at $6^{\circ}C$, and for two freeze/unfreezing cycles. The validated determination method successfully quantified the concentrations of OP 1206 in plasma samples from simulated administrating a single $5{\mu}g$ OP 1206 formulation. Thus, this novel LC-MS/MS technique for drug separation, detection and quantitation is expected to become the standard highly-sensitive detection method in bioanalysis and to be applied to many low dose pharmaceutical products.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF