• Title/Summary/Keyword: Auto detection

Search Result 354, Processing Time 0.029 seconds

Characteristics of source localization with horizontal line array using frequency-difference autoproduct in the East Sea environment (동해 환경에서 차주파수 곱 및 수평선배열을 이용한 음원 위치추정 특성)

  • Joung-Soo Park;Jungyong Park;Su-Uk Son;Ho Seuk Bae;Keun-Wha Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2024
  • The Matched Field Processing (MFP) is an estimation method for a source range and depth based on the prediction of sound propagation. However, as the frequency increases, the prediction inaccuracy of sound propagation increases, making it difficult to estimate the source position. Recently proposed, the Frequency-Difference Matched Field Processing (FD-MFP) is known to be robust even if there is a mismatch by applying a frequency-difference autoproduct extracted from the auto-correlation of a high frequency signal. In this paper, in order to evaluate the performance of the FD-MFP using a horizontal line array, simulations were conducted in the environment of the East Sea of Korea. In the area of Bottom Bounce (BB) and Convergence Zone (CZ) where detection of a sound source is possible at a long range, and the results of localization were analyzed. According to the the FD-MFP simulations of horizontal line array, the accuracy of localization is similar or degraded compared to the conventional MFP due to diffracted field and mismatch of sound speed. There was no clear result from the simulations conforming that the FD-MFP was more robust to mismatch than the conventional MFP.

Development of a Prototype System for Aquaculture Facility Auto Detection Using KOMPSAT-3 Satellite Imagery (KOMPSAT-3 위성영상 기반 양식시설물 자동 검출 프로토타입 시스템 개발)

  • KIM, Do-Ryeong;KIM, Hyeong-Hun;KIM, Woo-Hyeon;RYU, Dong-Ha;GANG, Su-Myung;CHOUNG, Yun-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.63-75
    • /
    • 2016
  • Aquaculture has historically delivered marine products because the country is surrounded by ocean on three sides. Surveys on production have been conducted recently to systematically manage aquaculture facilities. Based on survey results, pricing controls on marine products has been implemented to stabilize local fishery resources and to ensure minimum income for fishermen. Such surveys on aquaculture facilities depend on manual digitization of aerial photographs each year. These surveys that incorporate manual digitization using high-resolution aerial photographs can accurately evaluate aquaculture with the knowledge of experts, who are aware of each aquaculture facility's characteristics and deployment of those facilities. However, using aerial photographs has monetary and time limitations for monitoring aquaculture resources with different life cycles, and also requires a number of experts. Therefore, in this study, we investigated an automatic prototype system for detecting boundary information and monitoring aquaculture facilities based on satellite images. KOMPSAT-3 (13 Scene), a local high-resolution satellite provided the satellite imagery collected between October and April, a time period in which many aquaculture facilities were operating. The ANN classification method was used for automatic detecting such as cage, longline and buoy type. Furthermore, shape files were generated using a digitizing image processing method that incorporates polygon generation techniques. In this study, our newly developed prototype method detected aquaculture facilities at a rate of 93%. The suggested method overcomes the limits of existing monitoring method using aerial photographs, but also assists experts in detecting aquaculture facilities. Aquaculture facility detection systems must be developed in the future through application of image processing techniques and classification of aquaculture facilities. Such systems will assist in related decision-making through aquaculture facility monitoring.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Report on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test (Anti-ds DNA 항체 검사 시 Lipemic 검체의 영향에 관한 보고)

  • Cheon, Jun Hong;Kim, Whe Jung;Kim, Sung Ho;Moon, Hyoung Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.153-157
    • /
    • 2014
  • Purpose: SLE (systemic lupus erythematosus) is an inflammatory autoimmune disease, characterized by various autoantibody. The detection of Anti double-stranded DNA (Anti-ds DNA) is important in the diagnostics of SLE, and include the American College of Rheumatology (ACR) diagnostic criteria for SLE. Also SLE disease activity and correlativity with the level Anti-ds DNA antibody have been reported and Anti-ds DNA antibody quantitative test is very useful for tracing before and after SLE treatment. When These Anti-ds DNA antibody test (Farr assay: $^{125}I$ labeled ds-DNA and bound Anti-ds DNA antibodies complex in serum is precipitated by ammonium sulfate and used to centrifugation, measured it) inhaled supernatant after centrifugation, a lipemic specimen does not facilitate the formation of precipitate and also occurs situation was inhaled with precipitate. To solve these problems, The Influence of the degree of lipemic specimen was evaluated. Materials and Methods: September 2012 to February 2013, We selected lipemic samples (n=81) of specimen commissioned by Anti-ds DNA antibody test. Lipemic samples were done pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) used a micro-centrifuge (Eppendorf Model 5415D). At the same time lipemic specimen and pre-treatment samples were performed Anti-ds DNA antibody test (Anti-ds DNA kit, Trinity Biotech, Ireland). Statistical analysis were analyzed Pearson's correlation coefficients and regression and paired t-test, and Difference (%). Results: Experimental group 1 (Lipemic Specimen Anti-ds DNA Ab concentration ${\leq}7IU/mL$) at y=0.368X+4.732, $R^2=0.023$, Pearson's correlation coefficient was 0.154, paired t-test (P=0.003), Difference (%) mean 65.7 and showed a statistically significant difference. Experimental group 2 (Lipemic Specimen Anti-ds DNA Ab concentration ${\geq}8IU/mL$) at y=0.983X+0.298, $R^2=0.994$, Pearson's correlation coefficient showed 0.997, paired t-test (P=0.181), Difference (%) mean -5.53 made no statistically significant difference. Conclusion: Lipemic sample of low Anti-ds DNA Ab concentration (2.5-7 IU/mL) and the result is obtained pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) were made a significant difference statistically. Anti-ds DNA is one of the primary auto-antibodies present in patients with SLE, and remain an important diagnostic test for SLE. Therefore, we recommend preprocessing (high-speed centrifugation: 14,000 rpm 5 mins) in order to exclude the influence of lipemic specimen.

  • PDF