• 제목/요약/키워드: Auditory Perception Test

검색결과 37건 처리시간 0.024초

발성장애 환자에서 주관적 음성검사와 객관적 음성검사의 연관성 연구 (Study for Correlation between Objective and Subjective Voice Parameters in Patients with Dysphonia)

  • 박정우;김보람;오재환;강태규;김동영;우주현
    • 대한후두음성언어의학회지
    • /
    • 제30권2호
    • /
    • pp.118-123
    • /
    • 2019
  • Background and Objectives Voice evaluation is classified into subjective tests such as auditory perception and self-measurement, and objective tests such as acoustic and aerodynamic analysis. When evaluating dysphonia, subjective and objective test results do not always match. The purpose of this study was to analyze the relationship between subjective and objective evaluation in patients with dysphonia and to identify meaningful parameters by disease. Materials and Method The total of 322 patients who visited voice clinic from May 2017 to May 2018 were included in this study. Laryngeal lesions were identified using stroboscopy. Pearson correlation test was performed to analyse correlation between subjective tests including GRBAS scale and voice handicap index, and objective tests including jitter, shimmer, noise to harmonic ratio (NHR), cepstral peak prominence (CPP), maximal phonation time (MPT), mean flow rate, and subglottic pressure. Results In vocal nodule and sulcus vocalis, among GRBAS system, grade and breathiness showed good correlation with CPP, and roughness showed good correlation with jitter or shimmer. In unilateral vocal cord paralysis (UVCP), grade and breathiness showed a very good correlation with CPP, and also good correlation with jitter, shimmer, NHR, and MPT. Also asthenia showed good correlation with CPP and MPT. Vocal polyp has a limited association with other diseases. Conclusion In patients with dysphonia, grade and breathiness showed good correlation with CPP, jitter, and shimmer, and reflect the state of voice change well especially in UVCP, CPP, and MPT.

청감실험에 의한 공동주택 바닥충격음의 평가등급 설정 (Rating Floor Impact Noise in Apartment Buildings Through Subjective Evaluation Tests)

  • 전진용;류종관
    • 한국음향학회지
    • /
    • 제22권2호
    • /
    • pp.88-95
    • /
    • 2003
  • 본 논문에서는 바닥충격음의 감성적 상하한치를 기준으로 바닥충격음의 감성적 평가등급을 설정하기 위하여 바닥충격음 레벨에 따른 피험자의 주관적 반응을 현장 청감실험을 통하여 조사하였다. 표준 바닥충격원인 중량, 경량 충격음과 현재 일본에서 신 중량충격원으로 제안되고 있는 고무공충격음, 그리고 실제 충격음 (Jumping)을 대상으로 청감실험을 실시하였으며 청감실험에 사용된 주관적 반응의 평가척도로는 일본 건축학회에서 활용되고 있는 3개의 평가척도와 소음평가어휘를 활용한 평가척도를 사용하였다. 청감실험 결과, 바닥충격음 레벨에 따른 주관적 반응의 관계는 1차 회귀식으로 나타났으며, 감성적 하한치가 중량충격음의 경우 역A특성 가중 바닥충격음 레벨 (L/sub i, Fmax, AW/)이 46㏈, 경량충격음의 경우 역A특성 가중 규준화 바닥충격음 레벨 (L'/sub n, AW/)이 56㏈로 나타났다. 최종적으로 청감실험 결과에서 도출된 감성적 하한치의 기준으로 총 3등급의 평가등급이 설정되었다.

지각 특성 및 라우드니스를 이용한 입체음향의 성능 개선 (Enhancement of the 3D Sound's Performance using Perceptual Characteristics and Loudness)

  • 구교식;차형태
    • 방송공학회논문지
    • /
    • 제16권5호
    • /
    • pp.846-860
    • /
    • 2011
  • 인간의 청각기관은 소리의 방향과 거리인지에 있어서 양 귀에 들어오는 소리세기의 차이, 위상의 차이, 그리고 주파수 스펙트럼의 차이 등의 정보들을 복합적으로 이용한다. 이런 정보를 종합적으로 포함하고 있는 것을 머리전달함수라 하며, 이를 이용하여 실질적으로 존재하지 않는 음원을 근사적으로 생성할 수 있는 입체음향 시스템을 구현할 수 있다. 그러나 비개인화 된 머리전달함수는 음상정위 성능을 떨어뜨리는 주된 원인이 된다. 이에 본 논문에서는 이 머리전달함수를 이용한 3차원 음상정위를 위해 사람의 청각 특성을 이용한 알고리즘을 제안한다. 청자가 정확한 방향을 인지하기 위해 1차로 측정된 머리전달함수의 청각 자극 에너지를, 2차로 전역 마스킹 임계치와 라우드니스를 이용하여 방향감을 강조하였다. 제안된 알고리즘의 성능 평가를 위해 청감 테스트를 수행하였으며 실험결과 기존의 알고리즘에 비해 입체음향의 전체적인 인지도가 50% 이상 증가하였음을 확인할 수 있었다.

Changes in the Laterality of Functional Connectivity Associated with Tinnitus: Resting-State fMRI Study

  • Shin, Yeji;Ryu, Chang-Woo;Jahng, Geon-Ho;Park, Moon Suh;Byun, Jae Yong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.55-64
    • /
    • 2019
  • Purpose: One of the suggested potential mechanisms of tinnitus is an alteration in perception in the neural auditory pathway. The aim of this study was to investigate the difference in laterality in functional connectivity between tinnitus patients and healthy controls using resting state functional MRI (rs-fMRI). Materials and Methods: Thirty-eight chronic tinnitus subjects and 45 age-matched healthy controls were enrolled in this study. Connectivity was investigated using independent component analysis, and the laterality index map was calculated based on auditory (AN) and dorsal attention (DAN), default mode (DMN), sensorimotor, salience (SalN), and visual networks (VNs). The laterality index (LI) of tinnitus subjects was compared with that of normal controls using region-of-interest (ROI) and voxel-based methods and a two-sample unpaired t-test. Pearson correlation was conducted to assess the associations between the LI in each network and clinical variables. Results: The AN and VN showed significant differences in LI between the two groups in ROI analysis (P < 0.05), and the tinnitus group had clusters with significantly decreased laterality of AN, SalN, and VN in voxel-based comparisons. The AN was positively correlated with tinnitus distress (tinnitus handicap inventory), and the SalN was negatively correlated with symptom duration (P < 0.05). Conclusion: The results of this study suggest that various functional networks related to psychological distress can be modified by tinnitus, and that this interrelation can present differently on the right and left sides, according to the dominance of the network.

주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가 (Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment)

  • 전진용;김경호;정정호;류종관;조문재
    • 한국소음진동공학회논문집
    • /
    • 제12권6호
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

음성진전 유무에 따른 내전형 연축성 발성장애의 보툴리눔 독소-A 주입 후 음성 특성 변화 양상 (The Aspect of Voice Characteristics Change after Botulinum Toxin-A Injection in Patients with Adductor Spasmodic Dysphonia according to Vocal Tremor)

  • 고혜주;최홍식;임성은;최예린
    • 말소리와 음성과학
    • /
    • 제4권4호
    • /
    • pp.95-107
    • /
    • 2012
  • As BTX-A, which has been known to be the most effective treatment for ADSD, is not effective in treating vocal tremors, voice assessment must be employed to perform differential diagnosis of SD and vocal tremor in an accurate fashion. In this study, the characteristics of vocal changes after botulinum toxin injection were compared by analyzing the voice characteristics resulting from the presence of vocal tremors using objective analysis devices, with the aim of helping to provide prognoses and to determine remedial effects in clinical cases comprising patients with adductor spasmodic dysphonia accompanied by voice tremors. Respiratory function tests, aerodynamic analysis, electroglottography (EGG), acoustic analysis, auditory perception tests, and K-VHI had been conducted at intervals of four, eight, and twelve weeks before and after injection, targeting a group of 17 ADSD female patients (a ADSD group of four with vocal tremor and a ADSD group of 13 without voice tremor). For average FVC and FEV1, the T group showed statistically significant low averages compared with the NT group, whereas the T group showed statistically significant high average ATRI compared with the NT group. In addition, the T group showed a statistically significant Fatr, lower than that of the NT group. For the ADSD group of patients with voice tremor, their vocal tremor remained unchanged despite noticeable decrease in wringing voices. In other words, as the vocal tremor and wringing voices are two distinctive features, there is a need for the two features to be targeted separately for differential diagnosis.

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • 대한인간공학회지
    • /
    • 제34권1호
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.