1946년 Metz가 Impedance audiometry를 처음 임상에 응응한 이래 많은 연구가 진행되고 있다. Brooks, Jeger, Cooper 같은 학자들의 발표가 있었고, 최근 우리나라에서도 Impedance audiometry의 결과를 보고한 바가 있다. 금번 본 교실에서는 1977년 11월부터 1979년 2월까지 본병원 이비인후과 외래에 비폐색과 난청을 주소로 하여 내원한 7세부터 16세까지의 학동기 아동 100명을 대상으로 검이경 검사와 Impedance Audiometry를 시행하여 Types of tympanogram, Static compliance 및 Acoustic reflex에 대한 연구결과를 문헌 고찰과 함께 보고하는 바이다.
Objectives: Automated audiometry provides an opportunity to do audiometry when there is no direct access to a clinical audiologist. This approach will help to use hearing services and resources efficiently. The purpose of this study was to review studies related to automated audiometry by focusing on the implementation of an audiometer, the use of transducers and evaluation methods. Methods: This review study was conducted in 2017. The papers related to the design and implementation of automated audiometry were searched in the following databases: Science Direct, Web of Science, PubMed, and Scopus. The time frame for the papers was between January 1, 2010 and August 31, 2017. Initially, 143 papers were found, and after screening, the number of papers was reduced to 16. Results: The findings showed that the implementation methods were categorized into the use of software (7 papers), hardware (3 papers) and smartphones/tablets (6 papers). The used transducers were a variety of earphones and bone vibrators. Different evaluation methods were used to evaluate the accuracy and the reliability of the diagnoses. However, in most studies, no significant difference was found between automated and traditional audiometry. Conclusions: It seems that automated audiometry produces the same results compared with traditional audiometry. However, the main advantages of this method; namely, saving costs and increased accessibility to hearing services, can lead to a faster diagnosis of hearing impairment, especially in poor areas.
Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.
1946년 Metz가 impedance audiometry를 처음 임상적으로 응용한이래 많은 연구가 계속되고 있다. Brooks는 4세 부터 11씨 소아 1053명에 대한 electroacoustic impedance bridge의 결과를 보고하였고, J. Jerger는 6세이상 소아 398에 대한 impedance audiometry의 결과를 보고하였으며, Cooper 등은 소아 539명에 대한 conventional audiometry technic과 impedance audiometry와의 정확도를 비교 발표하였다. 우리나라에서는 1974년 서울대학교 이비인후과에서 처음으로 madsen impedance bridge를 도입하였고 다음으로 본원에서 1976년 teledyne impedance를 사용하여 1976년 9월 학동기 아동(7세부터 14세) 1023명에 대한 결과를 보고하였고 이번에는 1세부터 6세까지의 유소아 110명에 대한 impedance audiometry의 결과를 문헌고찰과 함께 보고하는 바이다.
This study was conducted to investigate hypoacusis due to workplace noise among dental technicians. Pure tone audiometry, impedance audiometry and heart rate variability were measured for 60 dental technicians and office workers in D city from July to November 2013, and a survey on the effects of noise was conducted. SPSS 19.0 was used for statistical analysis. In the result for threshold of pure tone audiometry, the average hearing threshold of left ears in the air conduction (AC) test showed a statistically significant decrease (P=0.019) among dental technicians, who are frequently exposed to workplace noise. The hearing threshold in the AC test for each frequency was significantly different between the two groups at 125 Hz (P=0.012) in right ears and at 1 kHz (P=0.022), 2 kHz (P=0.040), and 8 kHz (P=0.018) in left ears. Dental technicians who had worked for 16 years or longer had a significantly higher incidence of hypoacusis in the right ear (P=0.030) and in the left ear (P=0.010). In impedance audiometry showed a tympanometry result of type A in both the dental technician group and the office worker group.
Harford는 구씨관기능의 측정에 impedance audiometry의 진단학적 가치를 설명한 바 있다. 고막에 천공이 없는 경우 중이강내의 과도한 음압은 tympanogram에 의해 간접적으로 구씨관기능부전을 나타내는 것은 주지의 사실이다. 구씨관기능이 정상인 경우 valsalva maneuver에 의해 고막은 외측으로 밀려나갈 것이며 이것은 balance meter needle의 운동을 야기시킬 것이다. 이에 저자들은 고막, 중이, 구씨관기능이 모두 정상소견을 보이는 사람을 대상으로 valsalva maneuver에 의해 야기될 수 있는 balance meter needle의 운동거리를 측정함으로써 정상인에서의 구씨관에 의한 중이강의 공기체적의 변동양을 조사하였다. 즉, electroacoustic bridge (Madsen ZO 70) with silicone rubber probe tip을 사용하여 고막, 중이, 구씨관기능이 모두 정상인 사람에서 valsalva maneuver에 의한 balance meter needle의 운동범위는 1.0~4.0(평균치 $1.6{\pm}0.06$)이었으며, 그 치가 1.0미만인 경우에는 어떤 정도의 구씨관기능의 저하 내지 부전을 진단할 수 있는 것으로 생각되어 impedance audiometry에 의한 구씨관기능검사의 의의를 고찰하며 보고하는 바이다
As using recruitment phenomenon, SISI test and Bekesy audiometry are employed to differentially diagnose both the cochlear hearing loss and the retrocochlear hearing loss. The main purpose of this study is to find out the sensitivity and specificity of the SISI test within the scope of 1 KHz to 4 KHz in diagnosing various types of hearing losses. In this study, the Bekesy audiometry was conducted for Bekesy audiograms of certain groups according to Jerger's classification, which included persons with normal hearing and patients with hearing impairment. Subject persons of the SISI test were categorized into the several groups with normal hearing, mild hearing loss, moderate hearing loss, moderate-severe hearing loss and severe hearing loss, respectively. The sensitivity and specificity of certain groups were evaluated according to the SISI scores of 20 % below, 25 ${\sim}$ 65 %, and more than 70%. Also, the Bekesy audiometry is conducted on the several subject groups with normal hearing, mixed hearing loss, and sensori-neural hearing loss.
The purpose of this study was to develop a computer-animated pure tone audiometry for screening (CAPTAS) for toddler and to determine its validity and reliability. The CAPTAS utilizes an animated cartoon story producing visual and auditory stimuli. The intensities were 40 dB, 60 dB, 80 dB. The frequencies were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. The subjects were 20 (9 males and 11 females) severely hearing impaired children. As a result, The correlation coefficient between mean hearing threshold of children who were able to perform PTA and average hearing threshold of CAPTAS was performed and it revealed CAPTAS's high validity. And to verify the reliability of the re-test, all children had the CAPTAS and repeated it periodically. The result confirmed the reliability.
1946년 Metz가 처음으로 acoustic impedance bridge를 창안한 이후 많은 발전을 거듭하며 지금은 임상에 널리 이용되고 있으며 청각학에 많은 공헌을 하고 있다 우리나라에서도 이제 한국인의 정상치를 비롯한 많은 실험적 연구가 계속되고 있다. 저자는 본원에서 사용하고 있는 teledyne impedance (Model TA-ID)를 이용하여 나타난 Type C 때의 다음의 상관관계, 1. 이경소견과의 비교 2. 순음청력 역치와의 관계 3. Stapedial reflex와의 관계 4. 중이강내 압력과 참출물과의 상관관계 등을 조사하여 문헌고찰과 함께 보고하는 바이다.
This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.