• Title/Summary/Keyword: Audible

Search Result 265, Processing Time 0.028 seconds

Surgical Treatment for Aneurysm of Sinus of Valsalva Combined with Ventricular Septal Defect (심실중격결손을 합병한 Valsalva's 동 동맥류 파열의 치험예)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 1979
  • This is a case report of surgically treated rupture of Valsalva Sinus aneurysm combined with VSD. He has been relatively healthy until about one month before admission, when during bath, he felt abruptly palpitation, left chest pain and exertional dyspnea. These symptoms have progressed. On admission, thrill was palpable and continuous machinery murmur was audible on 2nd and 3rd intercostal space along the left sternal border. A rupture of Valsalva`s sinus aneurysm was confirmed by aortography and echocardiography but a small VSD was found by cardiotomy in open heart surgery. On 11th Sep. 1978, open heart surgery was performed. Valsalva`s sinus aneurysm came out from right coronary aortic sinus and ruptured into the right ventricle. It sized 1.2X1.5X1.5 cm. Ruptured opening was noted on apex of aneurysm [0.8X0.8cm], VSD [1. 0X0. 3cm in size] was just below the aortic annulus. The aneurysmal sac was removed on neck. After that, VSD and aneurysmal orifice were closed together with interrupted mattress sutures on same plane. The postoperative course was uneventful and discharged three weeks after open heart surgery.

  • PDF

Virtual Sound Localization algorithm for Surround Sound Systems (서라운드시스템을 위한 가상 음상정위 알고리즘)

  • Lee Sin-Lyul;Han Ki-Young;Lee Seung-Rae;Sung Koeng-Mo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.81-84
    • /
    • 2004
  • In this paper, we propose a virtual sound localization algorithm which improves the sound localization accuracy and sound color preservation for two channel and multi-channel surround speaker layouts. In conventional CPP laws, the sound direction is different from the panning angle and the sound color is different from real sound source especially when the speakers are spread out widely. To overcome this drawback, we design a virtual sound localization algorithm using directional psychoacoustic criteria (DPC) and sound color compensator (SCC). The analysis results show that in the case of the proposed system, the sound direction is the same as the panning angle in the audible frequency range and the sound color is less deviated from a real sound source than the conventional CPP law. In addition, its performance is verified by means of subjective tests using a real sound source.

  • PDF

A Study on the Watermarking Methods with Chi-Square Distribution (카이 자승 분포를 이용한 워터마킹기법의 연구)

  • 강환일;김갑일;한승수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.5-9
    • /
    • 2001
  • In this paper, we propose the new audio watermarking method and can be used on line processing. Instead of the wavelet transform, we use the integer wavelet transform for the reduction of the computational load. The watermark associated with the chi-square distribution is inserted into the signal on the integer wavelet domain. When extracting the watermark, the spread spectrum methods are used with the coefficients associated with the covariance sequence. We show that the chi-square distribution is a good tool for the spread spectrum method on the wavelet domain. This watermarking technique may be used for the control of the electrical product which can be controlled with the hidden signals and can be moved according to the audible signals simultaneously.

  • PDF

Arteriovenous Malformation of the Scalp : Efficacy of Computed Tomography Angiography

  • Moon, Kang-Seok;Yoon, Seok-Mann;Shim, Jai-Joon;Yun, Il-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.396-398
    • /
    • 2005
  • We report a rare case of scalp arteriovenous malformation[AVM]. A 55-year-old woman presented with a pulsatile palpable mass on her left temporo-parietal scalp. She complained of insomnia because of bruit, which was audible when she lay on her left side. Computed tomography angiography[CTA] for the scalp vessel showed AVM on the left temporo-parietal region. Multiple enlarged arteries, such as the superficial temporal artery, posterior auricular artery, and occipital artery, were directly connected to the elongated dilated superficial temporal vein. Digital subtraction angiography also showed similar results. Fistulous portions were clearly delineated on both modalities. Surgical excision of the malformations, including feeding arteries and the draining vein, resulted in immediate relief of the symptoms. Usefulness of CTA in the diagnosis of vascular lesions on the scalp was emphasized.

Tricuspid Valve Replacement: A Report of 8 Cases (삼첨 판막이식 8례 보고)

  • 김용진
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.185-193
    • /
    • 1978
  • Between April 1976 and March 1978, six cases of tricuspid valve replacement were done in the Department of Thoracic Surgery, Seoul National University Hospital. There were 4 men and 2 women and the age of the patients ranged from 17 years of the youngest to 48 years of the oldest. Most of them had characteristic symptoms of tricuspid valve disease, such as a systolic murmur audible over the lower sternum and varying with respiration, pulsatile and distended neck vein, and an enlarged and pulsatile liver. Preoperative functional levels according to NYHA Calcification were class III in 4 cases, and class IV in 2 eases. Most of the cases showed moderate to severe cardiomegaly in chest films and elevated right atrial pressure on preoperative right heart catheterization. Five of them underwent concomittent mitral valve replacement and one pulmonary valvotomy. All of them showed tricuspid insufficiency resulted from massive dilatation of annulus, destructive lesions of valve structure, or both anomalies. One postoperative hospital death was encountered and the cause of death was low out-put syndrome. All survivors showed clinical improvement and cardiomegaly regressed and left hospital in a good condition . *Attendum; Recently 2 more cases of tricuspid valve replacement with mitral valve replacement were done after this review.

  • PDF

Bilateral Coronary Artery-Pulmonary Artery Fistula - Reports of a Case- (양측 관상동맥-폐동맥간 동맥루 치험 1례)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.583-587
    • /
    • 1988
  • Bilateral coronary artery-pulmonary artery fistula is very uncommon congenital heart disease which occupy small percentage of all coronary arterio-venous fistulas. We experienced a case who was 52 years old female with bilateral coronary artery-pulmonary artery fistula. She complained exertional dyspnea k angina[coronary steal syndrome]. On physical examination, any cardiac murmur was not audible. There was no 0y step-up in right heart catheterization. But selective coronary angiography revealed tortuous aberrant vessels which originated from the canal branch of the right coronary artery k the left anterior descending coronary artery. Both aberrant vessels traversed the right ventricular outflow tract, and conjoined just proximal the pulmonic annulus and drained into the main pulmonary artery. The operation was performed under the extracorporeal circulation with beating heart. The procedures were suture-ligation of the draining orifice in main pulmonary artery & the feeding vessels on the right ventricular outflow tract. Postoperatively her complaints were completely disappeared and the selective coronary angiography revealed no left-to-right shunt.

  • PDF

GUI Environmental Controller Design with USB IF (USB IF를 이용한 GUI환경의 제어기 개발)

  • Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.449-454
    • /
    • 2003
  • In this paper, GU environmental controller is implemented with USB(Universal serial bus) IF(interface). Especially, the performance examination of ultrasound diagnostic device which connects external USB port with front panel is automatically inspected by VC++ examination program. The test program minimizes the operation of inspector with making the examined result audible or visible, and maximizes the productivity of custom device. The GUI environmental controller controls a standard keyboard, a track ball with dedicated buttons to emulate a standard two-button mouse, switches, rotary encoders, an analog potentiometer group, two alpha-numeric displays. and a touch screen; all of which generate events for the host.

  • PDF

Filtering of a Dissonant Frequency for Speech Enhancement

  • Kang, Sang-Ki;Baek, Seong-Joon;Lee, Ki-Yong;Sun, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3E
    • /
    • pp.110-112
    • /
    • 2003
  • There have been numerous studies on the enhancement of the noisy speech signal. In this paper, we propose a completely new speech enhancement scheme, that is, a filtering of a dissonant frequency (especially F# in each octave of the tempered scale) based on the fundamental frequency which is developed in frequency domain. In order to evaluate the performance of the proposed enhancement scheme, subjective tests (MOS tests) were conducted. The subjective test results indicate that the proposed method provides a significant gain in audible improvement especially for speech contaminated by colored noise and speaking in a husky voice. Therefore when the filter is employed as a pre-filter for speech enhancement, the output speech quality and intelligibility is greatly enhanced.

Is Feelings Enough For Meaning. (느낌 만이 뜻인가?)

  • Lee, Gun-Won
    • Korean Journal of Cognitive Science
    • /
    • v.2 no.1
    • /
    • pp.167-192
    • /
    • 1990
  • It is undeniable that the meanings usedinpractice are agreed feelings in the limited universe of discourerse of among the cognators of the linguistic expressions.The fact that the feelings are relative can be shown indirectly in terms of the indeterminacy of translations,because the feelings are not the physical object which can be visible or audible.However the agreed feelins also are not the absolute meanings,therefore these agreemnts are also relative depending on the situations used.

A PVDF Acoustic Sensor for Identifying Sound Source Frequencies (음원주파수 판별을 위한 PVDF 음향센서)

  • 이용국;최용일;송유리;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.202-204
    • /
    • 1995
  • An acoustic sensor using PVDF film is proposed in this paper. And its properties, such as sensitivity level, identification of sound source frequencies. and directivity, were experimented. Sensitivity level measured at the distance of 1[m] was limited in the range of ${\pm}$10dB. Adjacent three frequencies were also tested to identify the frequency of sound sources. In the range of audible frequencies, it could distinguish the frequencies of a complex sound. In addition, it was found that the sensor outputs were maximum in the coincided direction with a source, when directivity was experimented with three sound sources and FFT. The proposed PVDF film sensor has good characteristics of directivity and identifying ability as an acoustic sensor.

  • PDF