• 제목/요약/키워드: Attenuation relation

검색결과 71건 처리시간 0.027초

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

개발 예정지역 도로교통소음 음향파워레벨 산정과 응용에 관한 연구 (A Study on the Computation and Application of Sound Power Level for Road Traffic Noise of Renewal Area)

  • 김득성;장서일
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.635-644
    • /
    • 2005
  • This paper is. a study on relation between road traffic noise(RTN) and sound power level(PWL). At present, many experimental formulae and prediction formulae are used for prediction of RTN. But these formulae are difficult to appiy to the metropolitan area because these formulae are inaccurate in the different condition from reference condition. This paper calculate RTN and PWL of each prediction formula, choose the best one and make a noise map of the subject area. Procedure is as follows. First, calculate $L_{eq}$ of RTN using experimental formulae and prediction formulae. Second, calculate PWL using $L_{eq}$ of RTN and distance attenuation for point source at semi-free field. Third, choose the most accurate formula. And finally, make a noise map of the subject area at present and future. The result using noise map will be able to apply to application field. Noise mapping tool used on this paper is Raynoise program using Ray Tracing Method(RTM), Mirror Image Source Method(MISM) and Hybrid Method(HM).

An empirical bracketed duration relation for stable continental regions of North America

  • Lee, Jongwon;Green, Russell A.
    • Earthquakes and Structures
    • /
    • 제3권1호
    • /
    • pp.1-15
    • /
    • 2012
  • An empirical predictive relationship correlating bracketed duration to earthquake magnitude, site-to-source distance, and local site conditions (i.e. rock vs. stiff soil) for stable continental regions of North America is presented herein. The correlation was developed from data from 620 horizontal motions for central and eastern North America (CENA), consisting of 28 recorded motions and 592 scaled motions. The bracketed duration data was comprised of nonzero and zero durations. The non-linear mixed-effects regression technique was used to fit a predictive model to the nonzero duration data. To account for the zero duration data, logistic regression was conducted to model the probability of zero duration occurrences. Then, the probability models were applied as weighting functions to the NLME regression results. Comparing the bracketed durations for CENA motions with those from active shallow crustal regions (e.g. western North America: WNA), the motions in CENA have longer bracketed durations than those in the WNA. Especially for larger magnitudes at far distances, the bracketed durations in CENA tend to be significantly longer than those in WNA.

Acute Cyclosporin A-Treatment Impairs the Cytosolic Guanylate Cyclase-Mediated Vasodilatation in Rat Thoracic Aorta

  • Kook, Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권4호
    • /
    • pp.471-477
    • /
    • 1998
  • Cyclosporin A (CsA), a widely used immunosuppressant, is well known to cause nephrotoxicity and hypertension as major side effects. The present study was aimed at investigating the effects of CsA-pretreatment on the activities of cytosolic guanylate cyclase (cGC) in relation to the alteration of relaxant responses in the rat thoracic aorta. CsA $(10\;{\mu}M)-preincubation$ for 90 min significantly attenuated the vasodilatation induced by sodium nitroprusside (SNP), a cytosolic guanylate cyclase activator, shifting the dose-response curve to the right. The increase in cGMP contents induced by SNP was markedly attenuated by CsA. SNP ($1\;{\mu}M{\sim}\;mM$) increased the cGC activity dose-dependently, and the increase was completely abolished by CsA. CsA attenuated the SNP-induced cGC activation dose-dependently. The abolishing effect of CsA-pretreatment on the SNP-induced cGC activation was not affected by washing the preparation, suggesting that the inhibition is irreversible. When CsA was added simultaneously with SNP, cGC activation was not attenuated. 1-(5-isoquinolinylsulfonyl)-2-methyl piperazine (H-7), a protein kinase C (PKC) inhibitor, decreased SNP-induced cGC activation and blocked the CsA-attenuation of cGC activation. These results suggest that CsA directly inhibits cGC participating in the CsA-induced impairment of vasodilatation, and that PKC is involved in the inhibitory action of CsA on cGC.

  • PDF

20C 한반도 지진활동 특성과 영월지진(1996년12월13일)의 피해 및 진도 분석 (Characteristics of Seismic Activity in the 20th century and Analysis on the Damage and Intensity of Yeongwol Earthquake(December, 13, 1996))

  • 경재복
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.77-87
    • /
    • 1997
  • The earthquake data(M$\geq$4.0) for post-1900 in the Korean Peninsula show temporal variation with active and quiet periods. The pattern is quite similar to northeastern China and Inner Zone of Southwest Japan. Yeongweol earthquake occurred in the seismic gap region of the Korean Peninsula. This is the first medium-size earthquake in inland region of the southern peninsula since 1978. The intensity based on the felt area estimation of about 400 places shows MMI III-Ⅷ in inland region. IIon Cheju Island and Ion Ulreung Island. The isoseismal of MMI Ⅶ shows an elongated circle in the direction of NE-SW and covers some parts of Jungdong-myon, Yeongweol-kun, Sindong-eup and Nam-myun, Jeongseon-kun. There occurred quite strong shaking, numerous cracks on the walls of buildings, falling and movement of slate and tiles on the roofs, falling of tiles from the wall and falling of materials from desks, rook falling from mountain and collapse of gravel lauers on the river side. The least square fitting of the intensity data of the Yeongweol earthquake by a popular intensity attenuation relation yields the following : I=Io+1.82249 - 0.65295*InR - 0.00707*R

  • PDF

Breakup Characteristics of Impinging and Swirl Type Injectors

  • 윤영빈
    • 한국분무공학회지
    • /
    • 제10권4호
    • /
    • pp.32-46
    • /
    • 2005
  • The breakup characteristics of liquid sheets formed by the impinging and swirl type injectors were studied as increasing the Weber number (or injection condition) and the ambient gas pressure to 4.0.MPa. In the case of impinging type injector. we compared the changes of breakup lengths between laminar and turbulent sheets. which are formed by the impingement of laminar and turbulent jets. respectively. The results showed that both sheets expand as increasing the injection velocity irrespective of the ambient gas density when the gas based Weber number is low. When the Weber number is high, however, the breakup of turbulent sheet depends on the hydraulic force of jets as well as the aerodynamic force of ambient gas which determines the breakup of laminar sheet. Using the experimental results. we could suggest empirical models on the breakup lengths of laminar and turbulent sheets. In the case of swirl type injector. as $We_l$, and ambient gas density increased, the disturbances on the annular liquid sheet surface were amplified by the increase of the aerodynamic forces. and thus the liquid sheet disintegrated near from the injector exit. Finally, the measured breakup length of swirl type injector according to the ambient gas density and $We_l$, was compared with the result by the linear instability theory. We found that the corrected breakup length relation derived from linear instability theory considering the attenuation of sheet thickness agrees well with our experimental results.

  • PDF

도심지 재개발사업 환경영향평가시 소음지도 적용방안에 관한 연구 (Utilizing Noise Mapping in Environmental Impact Assessment in a Downtown Redevelopment Area)

  • 이시원;박영민;최진권;장서일
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1311-1317
    • /
    • 2005
  • In environmental Impact assessment, noise impact assessment usually consists of three stages-surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of a project. The distance-attenuation relation of a point source, which has been used to predict the noise level due to its simplicity does not consider complex acoustic phenomena like multi-reflection, -diffraction and -absorption due to complex topographic configuration of buildings and terrains. For the consideration of such physical complexities. a noise mapping tool is adopted to produce a series of noise maps, which are those for the present, tot the works of construction and for the future. For accurate noise mapping, acoustical and topographic Information is used. Standard sound power levels and directivities of various construction equipments are need and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.

관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석 (The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy)

  • 김병태;궁성수;범희승;정준기;박영배;이명철;이영우;고창순
    • 대한핵의학회지
    • /
    • 제21권2호
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.65-75
    • /
    • 1971
  • 국내에서 산출되는 각종 광물골재를 사용하여 방사선 차폐용 중차폐 콩크리트를 제조하고 감마선에 대한 차폐 효과를 실험한 결과 최적하다고 판단된 자철광 중차폐 콩크리트를 대상으로 60Co 감마선의 Broad beam을 사용하여 방사선 차폐 효과를 측정하였다. 본 실험을 통하여 실험적으로 차폐체내의 방사선의 감쇄곡선으로부터 차폐 체 두께의 변화에 따르는 방사선 투과율과의 상호관계에 관한 수식을 다음과 같이 유도해냈다. I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$$10^{-1}$X-3.38$\times$$10^{-3}$X$^2$+5.29$\times$$10^{-5}$X$^3$) X< 20 cm 때, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$$10^{-2}$ X+2.12$\times$$10^{-1}$) X>20 cm 때. 이와같이 얻은 결과식에서 오른쪽 첫번째항은 최초 감마선의 감쇄를 표시하고 그 다음항은 차폐체 내에서의 감마선 재생계수를 나타낸다. 이 실험에 첨가하여 차폐체의 실제 설계에 입각한 입방형 자철광 구조체 (두께 8 cm, 내부공간 40$\times$40$\times$40cm)에 대한 차폐효과를 측정한 결과 평판 차폐체를 사용할 때 보다 투과 방사선이 증가됨을 알았다.

  • PDF

EO-1 Hyperion 영상을 이용한 연안해역의 수심 추출 (Extraction of Water Depth in Coastal Area Using EO-1 Hyperion Imagery)

  • 서동주;김진수
    • 한국정보통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.716-723
    • /
    • 2008
  • 최근 과학기술의 급속한 발달과 더불어 인간의 활동 영역이 넓어짐으로써 연안해역 개발과 환경 등의 문제가 전세계적으로 대두되고 있으며, 보다 광범위한 분석을 위해 위성영상을 활용이 증대되고 있는 실정이다. 본 연구는 보다 효율적인 연안해역의 수심 결정에 있어 하이퍼스펙트럴 위성영상을 활용하는데 그 목적을 둔다. 이를 위해 먼저 EO-1 Hyperion 위성영상에서 연구대상지에 해당하는 부분영상을 추출하고, 대기보정과 기하보정을 실시하였다. 그리고 MNF 변환을 통해 밴드를 압축하고, 수체의 특성을 분석하는데 적합한 밴드를 선정하였다. 선정된 밴드내에서 수심 산정을 위한 계수인 Kd를 결정하였으며, 순수한 분광 특성을 가진 화소의 endmember의 결정과 선형분광순수화 기법을 이용한 매핑을 통해 대상 연안의 수심을 최종적으로 결정하였다. 연구 결과, 산정 된 수심은 수치해도상의 수심과 평균 1.2m 정도의 차이를 보였고, 산정 하고자 하는 수심이 깊을수록 오차는 크게 나타났다. 향후 대기보정, endmember 결정, Kd 산정 등의 정확도를 높인다면 보다 경제적이고 효율적인 수심 결정이 가능할 것으로 판단된다.