• 제목/요약/키워드: Attenuation of Noise

Search Result 477, Processing Time 0.024 seconds

Noise Attenuation by Landscape Woody Plants - Comparisons as a Hedge Species Between Japanese Spindle Tree & Oriental Arbor-vitae - (조경수목(造景樹木)의 소음감쇠효과(騷音減衰効果)에 관(關)한 연구(硏究) - 사철나무와 측백나무 수벽(樹壁)의 비교분석(比較分析) -)

  • Kim, Yong Shik;Chang, Ho Gyeong;Kim, Ye Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.1
    • /
    • pp.30-34
    • /
    • 1989
  • Effects on noise attenuation of the hedge species, Thuja orientalis L. and Euonymus japonicus Thunb., widely used as road side hedges, were analysed at the frequencies of 1,000, 2,000 and 3,150 Hz., respectively. The present experiments were carried out both in the field and in a Semianechoic Chamber. As increasing the distances from the noise source, attenuation rates of noise level were increased at high frequencies. But the attenuation rates of the noise level at low frequencies showed varied as the distances increased, and this trend appeared to be caused by the influence of ground waves. Generally, in this experiment, Thuja orientalis L., which is a coniferous species, showed more effective on the abilities of noise attenuation than that of Euonymus japonicus Thunb., which is a broad-leaved evergreen species.

  • PDF

An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings (공동주택에서의 화재 경보음 전달특성에 관한 연구)

  • Lee, Min-Joo;Kim, Myung-Jun;Yoon, Myong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

An Experimental Study on the Vibration Absorber for Vibration Attenuation of Cantilever Beam Structure (외팔보 구조물의 진동감쇠를 위한 동흡진기의 실험적 연구)

  • Kwag, Dong-Gi;Bae, Jae-Sung;Hwang, Jai-Hyuk;Kim, Hun-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.11
    • /
    • pp.991-996
    • /
    • 2011
  • This study was carried out vibration attenuation of vibration absorber attached to the cantilever beam structure. Modern tank guns are stabilized to allow fire on the move while traversing uneven terrain. However, as the length of the barrel is extended, to meet required muzzle exit velocities, the terrain induced vibrations lead to increased muzzle pointing errors. Thus, reducing these vibrations should lead to increased accuracy. The vibration absorber includes a compliant energy storage device, such as a spring, and a mass secured to the energy storage device. In this study, it accomplished a research in about gun barrel vibration attenuation using tuned mass damper. The barrel was hung from a bungee cord for free-free condition. It accomplished a vibration experiment for verified attenuation efficiency.

An Experimental study on the Vibration absorber for vibration attenuation of cantilever beam structure (외팔보 구조물의 진동감쇠를 위한 동흡진기의 실험적 연구)

  • Kwag, Dong-Gi;Bae, Jae-Sung;Hwang, Jai-Hyuk;Kim, Hun-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.627-632
    • /
    • 2011
  • This study was carried out vibration attenuation of vibration absorber attached to the cantilever beam structure. Modern tank guns are stabilized to allow fire on the move while traversing uneven terrain. However, as the length of the barrel is extended, to meet required muzzle exit velocities, the terrain induced vibrations lead to increased muzzle pointing errors. Thus, reducing these vibrations should lead to increased accuracy. The vibration absorber includes a compliant energy storage device, such as a spring, and a mass secured to the energy storage device. In this study, it accomplished a research in about gun barrel vibration attenuation using tuned mass damper. The barrel was hung from a bungee cord for free - free condition. It accomplished a vibration experiment for verified attenuation efficiency.

  • PDF

Study on noise attenuation according to hedge species (생울타리의 종에 따른 소음감소효과에 관한 연구)

  • Oh, Kwang-Il;Kim, Dong-Pil;Choi, Song-Hyun
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.3
    • /
    • pp.272-279
    • /
    • 2009
  • The purpose of this study is to examine noise attenuation according to hedge species and thickness of their leaves. The order of their decrease effects was as follows from the highest to the lowest: Osmanthus asiaticus, Camellia japonica, Pyacantha angustifolia, Photinia glabra, Pittosporum tobira, Nandina domestica, Euonymus japonica, Chaenomeles lagenaria, Aucuba japonica for. Variegatar. The result of the experiment for noise atteunation has shown that woody plant with thicker leaves were better than those with thinner leaves. Multiple Regression Analysis showed Y = 7.653 + 26.530 X ($R^2$= 0.385). The order for the subjects according to their effects on noise attenuation is as follows from the highest to the lowest: Camellia japonica, Nandina domestica, Pittosporum tobira, Taxus cuspidata, Chaenomeles lagenaria. The noise attenuation level of Camellia japonica was the highest (14.70[dB]), while that of Chaenomeles lagenaria was the lowest (6.80[dB]), and its difference between them was 7.9[dB].

A Study on the Sound Resonating Barrier (음향공명 방음벽 연구)

  • 이준신;김태룡;손석만;박동수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.659-664
    • /
    • 2001
  • Noise barriers are widely used to reduce the sound level propagating from highways, railways or factories to residential areas. The reduced noise level at a receiver point is then determined by the diffracted waves around the edge of the barrier as well as by the transmitted waves through the barrier. For proper usage, many studies either theoretical or experimental have been made with the objective of precisely predicting the acoustic field and improving the noise attenuating properties of barriers. In this study, a simple scattering model, a line acoustic source scattered by an infinite cylinder, is introduced to simply investigate the sound attenuation efficiency of a sound-resonating barrier. From this model study, it is observed that the sound-resonating barrier can be used as a good sound-shielding element especially for the pure-tone noise generated from the transformer. Large sound-attenuation is achieved by applying the sound-resonating barrier to the large transformers in a substation.

  • PDF

Channel Analysis of inside PLC (옥내 전력선 채널 분석)

  • Hong Duc-Pyo;Lee Jin-Mok;Kim Soo-Cheol;Choi Jae-Ho;Hong Hyun-Mun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.456-458
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. Signals don't affect to electric machine in PLC because they are very small voltage. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, the other is to choose the strong modulation method which sends signals long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. After all, impedance and noise problems of PLC channel must be overcame. Noises of 2 kinds which are AWGN abd impulse noise and attenuation are orated. To overcome the noise. Recently, Multi-carrier Modulation: MCM methods like as OFDM and DMT which are divide the channel into many sub-channel have been studied. those are powerful communication methods in PLC. In this paper, PLC channels made up of 3 numbers of noise and attenuation are simulated for getting BER by Matlab simulink.

  • PDF

Optimal Selection of Transducer Locations for Active Cancelation of Noise in a Duct (덕트내에서의 능동 소음 제거를 위한 Transducer의 최적 위치 선정)

  • 남현도;강택동
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.102-110
    • /
    • 1999
  • The attenuation property of active noise control system is much dependent on the locations of transducers. It is very difficult to retermine the orfunal locations of transducers analytically, because the acoustic behaviors in active noise control systems are very complex and the acoustic parameters, fluid density, corqJlex propagation, coefficients, etc., are usually unknown. In this paper, effects of positions of transducers and of distances between transducers on attenuation properties of active noise control systems is investigated via computer simulations. Tbe transfer functions between the transducers are derived using the superposition principle for computer simulations. Computer simulations show that the acoustic monopole and dipole systems for duct noise attenuation are sensitive to variations of the transducer location.

  • PDF

A Study on the Noise Attenuation Effects by Types of Forest Tree Belt (수림대(樹林帶)에 따른 소음감살효과(騷音減殺效果)에 관한 연구(硏究))

  • Lee, Ju-Hyoung;Kang, Gun-Uh
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.1
    • /
    • pp.113-123
    • /
    • 2001
  • The main purpose of this study was to provide information on attenuation effects in forest tree belt of pine stand and oak stand. The relationships between DBH, tree height, clear length, crown area and number of trees and also between distance from noise origin, landslope etc. were analysed by correlation and multiple regression. The results obtained were as follows : 1. There was no difference between pine stand and oak stand in effecting noise attenuation. 2. The noise pressure was highly correlated with all of seven elements tested and both DBH and distance from noise origin have higher r-values than the others. For the pine stand, it was 0.9133 in DBH and 0.9630 in the distance and for the oak stand, 0.9296 in DBH and 0.9565 in the distance. 3. The optimum regression equation for pine stand and oak stand were made by combination of two variables (DBH and distance). The table of noise attenuation was made by optimum regression equation. In the case of pine stand, the attenuation ratio was 29% at 5m, 31.6~32.6% at 10m, 38.3~39.8% at 20m and 45.2~46.6% at 30m. And case of oak stand, the attenuation ratio was 29% at 5m, 31.6~34.2% at 10m, 38.6~41.4% at 20m and 45~47.2% at 30m. 4. As the noise pressure limit at the Urban housing area according to environmental laws is under 55dB, it is suggested by the table of noise attenuation that the distance, and DBH for the pine and oak stand are over 20m, 400cm and 30-35 trees, respectively.

  • PDF

A Study on the Improvement of the Road Traffic Noise Prediction for Environmental Impact Assessment (환경영향평가시 도로교통소음예측에 관한 개선방안 연구)

  • Lee, Nae-Hyun;Park, Young-Min;Sunwoo, Young
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.4
    • /
    • pp.297-304
    • /
    • 2001
  • Recently the road traffic noise has appeared as a significant environmental issue because of dramatic increase of vehicles and expansion of newly constructed road. Therefore, this study proposes the method that improves prediction factors and models through analysis of the existing road traffic noise prediction model. Prediction factors can be improved by establishing guideline for diffraction attenuation and applying daily traffic discharge, peak traffic discharge, and average traveling speed through an analysis of level service. Prediction must be made by periods of one or five years during 20 years. Prediction models also can be improved to include better prediction model through setting the database, establishing functional relation between physical properties and noise levels by acoustic analysis, and developing models for road traffic noise prediction in residential areas.