• 제목/요약/키워드: Attenuation factors method

검색결과 52건 처리시간 0.031초

팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구 (IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT)

  • 김유현;여인환;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

M/W 중계 시스템 망의 주파수 조정을 위한 보호비 계산에 대한 연구 (A Study on Calculation of Protection Ratio for Frequency Coordination in Microwave Relay System Networks)

  • 서경환;이주환
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.125-130
    • /
    • 2005
  • This paper suggests an efficient method of protection ratio calculation and shows some calculated results applicable to frequency coordination in microwave relay system networks, and the net filter discrimination (NFD) associated with Tx spectrum mask and overall Rx filter characteristics has been examined to obtain the adjacent channel protection ratio. The protection ratio comprises several factors such as C/N of modulation scheme, noise-to-interference ratio, multiple interference allowance, fade margins of multi-path and rain attenuation, and NFD. According to computed results for 6.7 GHz, 64-QAM, and 60 km at BER $10^{-6}$, fade margin and co-channel protection ratio are 41.1 and 75.2 dB, respectively, In addition, NFD for channel bandwidth of 40 MHz reveals 28.9 dB at the first adjacent channel, which results in adjacent channel protection ratio of 46.3 dB. The proposed method provides some merits of an easy calculation, systematic extension, and applying the same concept to frequency coordination in millimeter wave relay system networks.

  • PDF

기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성 (The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method)

  • 위성훈;김준경;유성화
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.161-171
    • /
    • 2017
  • 관측된 지반진동은 지진원, 지각감쇠 및 지반의 증폭특성 등 3가지 주요 인자로 구성되어 있고 특히 지반증폭 특성은 지진원 및 감쇠특성을 평가할 때 필요하다. 또한 지진재해도를 분석하기 위해 지반의 증폭 특성에 정보가 내진공학 뿐만 아니라 암반공학적 특성 분석에서 필수적이다. 지반의 증폭특성 분석을 위해 분석대상 관측소와 기준 관측소 지반진동의 수평/수직 비를 이용하는 방법을 적용하였다. 기존의 기준관측소의 수직성분 방법에 더하여 새로이 기준관측소의 수평성분 방법을 새로이 시도하였다. 본 연구는 예당저수지 인근에 설치한 4개의 관측소에서 관측된 6개의 가속도 지반진동을 이용하여 각 지반진동의 S파, Coda파 및 배경잡음 각각을 분석한 지반증폭 특성을 상호 비교하였다. 4개 관측소 공통적으로 S파와 Coda파를 이용한 결과는 상호 유사한 지반증폭 특성을 보였다. 다만 배경잡음은 다른 2개 지진 에너지와 비교할 때 전혀 다른 지반증폭 특성을 보였고 이는 배경잡음의 발생 원인이 관측소 마다 서로 다르기 때문으로 입증되었다. 4개 각각의 지진 관측소마다 저주파수 및 고주파수 증폭특성과 관측소 고유의 우월주파수가 서로 상이하여 관측소 고유의 증폭특성을 보여주었다. 또한 본 연구의 결과와 다른 방법의 결과와 비교하면 지반의 동적특성 및 지반분류 연구에 많은 정보를 제시할 수 있다.

지표투과레이더(GPR)에 의한 도로포장의 전자기적 특성값 고찰 (A Consideration on the Electromagnetic Properties of Road Pavement Using Ground Penetrating Radar (GPR))

  • 이지영;심재원;이상래;이강현
    • 대한토목학회논문집
    • /
    • 제40권3호
    • /
    • pp.285-294
    • /
    • 2020
  • 본 연구는 실제 공용 중인 도로에서 약 20년에 걸쳐 지표투과레이더(GPR) 조사하고 도로포장의 전자기적 특성값인 유전상수와 감쇠에 대해 분석하였다. 그 결과로부터 도로포장의 일반적인 특성값 범위, 영향인자, 그리고 보정방법을 제시하였다. 비접촉식(Air-coupled) 1 GHz GPR 안테나로 조사한 아스팔트 포장의 일반적인 유전상수 범위는 4~7이었다. 콘크리트 포장의 경우 초기 재령에서는 유전상수가 매우 큰 값을 보였으나 재령이 경과할수록 급격하게 작아졌다. 재령 10년 이후에는 6~12 범위에 수렴하였다. 공기 중에 노출된 포장의 유전상수는 대기의 상대습도에 따라 증감하였으나 덧씌우기 포장층이 있는 경우 영향성은 1/8 수준으로 감소하였다. 레이더 파의 감쇠는 일반적으로 포장층의 두께가 증가할수록 커지게 되며, 손상 구간에서도 증가하였다. GPR 조사 시 기상조건에 따라서 포장의 전자기적 특성값이 달라질 수 있음을 확인하였으며, 특히 포장상태가 양호한 경우보다 손상이 발달한 상태에서 영향성이 크게 나타났다. 이밖에 동일한 주파수의 GPR 안테나로 조사한 경우에도 장비의 특성이 달라지면 결과값에 차이가 발생할 수 있었다. 따라서 GPR 조사는 도로에 대한 이해를 바탕으로 날씨의 변화가 거의 없고 도로표면이 깨끗한 상태에서 숙련자에 의해 실시하는 것이 필요하다. 또한 보정코어, 장비 보정 등을 통해 해석결과의 신뢰도를 향상하는 것이 요구된다.

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • 제8권4호
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

전력선 통신 채널 Data Base 구축을 위한 기본 연구 (A Fundamental Study for Establishment of Channel Data Base in Power-Line Communications)

  • 오휘명;김관호;이원태;이재조
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권2호
    • /
    • pp.107-111
    • /
    • 2003
  • In the power-line communication systems, there are many factors of noise and attenuation in the power-line channels, because they were designed for not the communication but the power transmission. Also the transfer function of the channels is highly changed with the topology and the load of the power-lines. To cope with these poor channel situation, channel modeling, one of the many studies in progress, is being studied hard. Channel modeling is essential to apply the active schemes to overcome the bad channel(e.g. modulation technique, channel coding, signal coupling & filtering, etc.) to the power-line communications. In this paper, we have realized the statistical model(this model is suggested as the channel modeling method for the power-line channels) that is combined the transfer function with the various noises. And we have compared and examined the results with the measured data. Also we have studied the plan which can effectively establish the channel data base for the channel information consisted of the parameters that are derived from this modeling, and we have studied the plan to utilize the data base.

Applied 2D equivalent linear program to analyze seismic ground motion: Real case study and parametric investigations

  • Soltani, Navid;Bagheripour, Mohammad Hossein
    • Geomechanics and Engineering
    • /
    • 제30권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Seismic ground response evaluation is one of the main issues in geotechnical earthquake engineering. These analyses are subsequently divided into one-, two- and three-dimensional methods, and each of which can perform in time or frequency domain. In this study, a novel approach is proposed to assess the seismic site response using two-dimensional transfer functions in frequency domain analysis. Using the proposed formulation, a program is written in MATLAB environment and then promoted utilizing the equivalent linear approach. The accuracy of the written program is evaluated by comparing the obtained results with those of actual recorded data in the Gilroy region during Loma Prieta (1989) and Coyote Lake (1979) earthquakes. In order to precise comparison, acceleration time histories, Fourier amplitude spectra and acceleration response spectra diagrams of calculated and recorded data are presented. The proposed 2D transfer function diagrams are also obtained using mentioned earthquakes which show the amount of amplification or attenuation of the input motion at different frequencies while passing through the soil layer. The results of the proposed method confirm its accuracy and efficiency to evaluate ground motion during earthquakes using two-dimensional model. Then, studies on irregular topographies are carried out, and diagrams of amplification factors are shown.

A Derivation of Aerosol Optical Depth Estimates from Direct Normal Irradiance Measurements

  • Yun Gon Lee;Chang Ki Kim
    • 신재생에너지
    • /
    • 제20권1호
    • /
    • pp.79-87
    • /
    • 2024
  • This study introduces a method for estimating Aerosol Optical Depth (AOD) using Broadband Aerosol Optical Depth (BAOD) derived from direct normal irradiance and meteorological factors observed between 2016 and 2017. Through correlation analyses between BAOD and atmospheric components such as Rayleigh scattering, water vapor, and tropospheric nitrogen dioxide, significant relationships were identified, enabling accurate AOD estimation. The methodology demonstrated high correlation coefficients and low Root Mean Square Errors (RMSE) compared to actual AOD500 measurements, indicating that the attenuation effects of water vapor and the direct impact of tropospheric nitrogen dioxide concentration are crucial for precise aerosol optical depth estimation. The application of BAOD for estimating AOD500 across various time scales-hourly, daily, and monthly-showed the approach's robustness in understanding aerosol distributions and their optical properties, with a high coefficient of determination (0.96) for monthly average AOD500 estimates. This study simplifies the aerosol monitoring process and enhances the accuracy and reliability of AOD estimations, offering valuable insights into aerosol research and its implications for climate modeling and air quality assessment. The findings underscore the viability of using BAOD as a surrogate for direct AOD500 measurements, presenting a promising avenue for more accessible and accurate aerosol monitoring practices, crucial for improving our understanding of aerosol dynamics and their environmental impacts.

대학생의 골초음파 상태에 영향을 미치는 영양요인 분석 (Relation Between Nutritional Factors and Bone Status by Broadband Ultrasound Attenuation among College Students)

  • 권세미;이병국;김희선
    • 한국식품영양과학회지
    • /
    • 제38권11호
    • /
    • pp.1551-1558
    • /
    • 2009
  • 본 연구는 최대 골질량에 도달하는 20대의 대학생 1039명(남학생 532명, 여학생 507명)을 대상으로 골초음파 상태와 영양소 섭취 및 생화학적 영양 상태를 나타내는 지표들과의 관계를 분석하였다. 대상자의 골밀도 수치에 따라 t-score$\underline{\geq}$-1인 정상 골밀도군과 t-score<-1 골감소군으로 분류하여 비교한 결과 남학생의 경우 정상 골밀도군이 90.4%, 골감소군이 9.6%이며 여학생의 경우 정상 골밀도군이 94.1%, 골감소군이 5.9%의 분포를 보였다. 체적지표인 BMI를 아시아-태평양 비만기준에 의거하여 분리하였을 때는 남학생은 저체중 3.4%, 정상+과체중 70.7%, 비만 25.9%, 여학생은 저체중 16.2%, 정상+과체중 76.5%, 비만 7.3%의 분포를 보였다. 정상 골밀도군과 골감소군의 골밀도와 생화학적 영양 상태는 남학생 여학생 모두 통계적으로 유의한 차이가 없었다. 전체대상자들의 영양소 섭취상태를 살펴 본 결과, 남학생의 경우 정상 골밀도군과 골감소군 간의 유의적인 차이가 나타나지 않았으나 여학생의 경우 동물성 단백질과 동물성 철분 섭취량이 정상 골밀도군에서 골감소군보다 유의하게 높았다. 평균 에너지 섭취량은 동일한 연령대의 한국인영양섭취기준(KDRIs)과 비교하였을 때, 각 남학생 정상골밀도군 약 74%, 골감소군 67%, 여학생 정상골밀도군 약 89%, 골감소군 81%의 섭취수준을 나타내었다. 평균 단백질섭취량은 남녀 두 군 모두 100%를 상회하는 섭취 양상을 나타냈으며, 강한 뼈를 유지하거나 각종 신진대사에 필수적인 영양소이기 때문에 골격건강에 가장 큰 영향을 미치는 칼슘의 경우 남학생과 여학생 모두 KDRIs와 비교하여 권장섭취기준의 약 63%정도로 부족한 것으로 나타났다. 골 건강 상태에 영향을 미치는 영양인자의 로지스틱 회귀분석 결과 연령, 성별 및 BMI를 교란변수로 통제하였을 경우 동물성 단백질, 동물성 철분 및 아연섭취는 골감소를 예방하는 보호 작용이 있는 것으로 나타났다. 동물성 단백질과 이들 미량 영양소의 섭취정도는 높은 식사의 질을 반영하므로 질적으로 우수한 식생활이 최대 골질량에 도달하는 시기인 20대의 골격형성과 건강을 위해 필수적인 것으로 사료된다.

전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가 (The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.21-25
    • /
    • 2010
  • PET/CT검사에 있어서 CT는 해부학적인 정보를 제공할 뿐 아니라 PET영상에 대한 감약 정보를 제공하는 역할을 하고 있다. CT의 감약차를 이용하는 것으로서 검사 부위에 존재하는 여러 가지 변수에 의해 그 정도가 달라질 수 있다. 이것은 현재 본 원에서 PET/CT검사 시에 팔을 몸 옆에 두고 검사하는 것에도 적용할 수 있으며, 이에 본 논문에서는 일부 타 병원에서 시행하고 있는 팔을 머리 위로 올리고 검사하는 방법과 함께 CT값의 변화에 따른 표준섭취계수의 변화를 비교 연구했다. NEMA 1994 PET 모형의 삽입체와 모형의 부피를 고려하여 4:1의 비율로 $^{18}F$-FDG를 주입하였다. 먼저 테플론 삽입체 두 개를 NEMA 1994 PET 모형의 양 옆에 고정시켜 팔을 내리고 있는 상태를 가정하여 영상을 얻었으며 테플론 삽입체를 제거하여 팔을 머리 위로 올린 상태를 가정하여 영상을 얻었다. 앞의 과정을 거쳐 얻은 영상을 재구성 하여 Volume Viewer를 이용해 한 영상면 당 5개의 관심 체적을 설정했고 각 측정값을 평균하여 얻어낸 CT값과 표준섭취계수로 그 변화를 측정하였다. 측정된 값과 폐 관련 암환자의 간에 관심 영역을 설정하고 측정한 값을 비교하여 실제 임상 영상에서의 차이를 측정하였다. 모형 실험결과 테플론 삽입체를 부착하였을 때보다 테플론 삽입체를 부착하지 않았을 때 CT값이 -5.8 HU에서 0 HU으로 평균 5.8 HU 증가하였고 표준섭취계수는 24.64에서 24.29로 평균 0.35 감소하였다. 축방향 균일도는 0.064에서 0.052로 평균 0.012 감소하였다. 환자 실험결과 팔을 내리고 검사하였을 때보다 팔을 머리 위로 올리고 검사하였을 때 CT값은 54.1 HU에서 59.9 HU로 평균 5.8 HU 증가하였고 표준섭취계수는 2.02에서 1.85로 평균 0.17 감소하였다. 테플론 삽입물을 부착한 상태로 검사할 때 보다 테플론 삽입물을 부착하지 않은 상태로 검사할 때 CT값은 증가하고 표준섭취계수는 감소하는 양상을 보였다. 이러한 현상이 일어나는 이유는 감약의 정도와 표준섭취계수의 상관관계에서 찾을 수 있다. CT값이 증가할수록 감약 계수는 비례하여 증가하는데 이것은 결국 CT값이 증가될수록 감약이 증가된다고 볼 수 있다. 따라서 팔에 의해 감약이 과다하게 측정될 수 있으므로 결국 표준섭취계수의 증가로 이어진다고 판단된다. 하지만 그 값의 차이가 매우 적어 진단적으로 유의한 범위라고 볼 수 없다. 팔을 머리 위로 올리고 검사하는 자세가 어깨 및 팔에의 $^{18}F$-FDG섭취와 환자의 고통을 야기하게 된다는 점들을 종합하여 고려해 보았을 때, PET/CT검사 시에는 팔을 내리고 검사하는 것이 합리적이나, 환자의 상태 및 영상의 질적 측면을 고려하여 결정하여야 하겠다.

  • PDF