Characteristics of Magnetic Resonance-Based Attenuation Correction Map on Phantom Study in Positron Emission Tomography/Magnetic Resonance Imaging System

  • Hong, Cheolpyo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.189-193
    • /
    • 2020
  • An MR-based attenuation correction (MRAC) map plays an important role in quantitative positron emission tomography (PET) image evaluation in PET/magnetic resonance imaging (MRI) systems. However, the MRAC map is affected by the magnetic field inhomogeneity of MRIs. This study aims to evaluate the characteristics of MRAC maps of physical phantoms on PET/MRI images. Phantom measurements were performed using the Siemens Biograph mMR. The modular type physical phantoms that provide assembly versatility for phantom construction were scanned in a four-channel Body Matrix coil. The MRAC map was generated using the two-point Dixon-based segmentation method for whole-body imaging. The modular phantoms were scanned in compact and non-compact assembly configurations. In addition, the phantoms were scanned repeatedly to generate MRAC maps. The acquired MRAC maps show differently assigned values for void areas. An incorrect assignment of a void area was shown on a locally compact space between phantoms. The assigned MRAC values were distorted using a wide field-of-view (FOV). The MRAC values also differed after repeated scans. However, the erroneous MRAC values appeared outside of phantom, except for a large FOV. The MRAC map of the phantom was affected by phantom configuration and the number of scans. A quantitative study using a phantom in a PET/MRI system should be performed after evaluation of the MRAC map characteristics.

Effect of filters and reconstruction method on Cu-64 PET image

  • Lee, Seonhwa;Kim, Jung min;Kim, Jung Young;Kim, Jin Su
    • 대한방사성의약품학회지
    • /
    • 제3권2호
    • /
    • pp.65-71
    • /
    • 2017
  • To assess the effects of filter and reconstruction of Cu-64 PET data on Siemens scanner, the various reconstruction algorithm with various filters were assessed in terms of spatial resolution, non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR). Image reconstruction was performed using filtered backprojection (FBP), 2D ordered subset expectation maximization (OSEM), 3D reprojection algorithm (3DRP), and maximum a posteriori algorithms (MAP). For the FBP reconstruction, ramp, butterworth, hamming, hanning, or parzen filters were used. Attenuation or scatter correction were performed to assess the effect of attenuation and scatter correction. Regarding spatial resolution, highest achievable volumetric resolution was $3.08mm^3$ at the center of FOV when MAP (${\beta}=0.1$) reconstruction method was used. SOR was below 4% for FBP when ramp, Hamming, Hanning, or Shepp-logan filter were used. The lowest NU (highest uniform) after attenuation & scatter correction was 5.39% when FBP (parzen filter) was used. Regarding RC, 0.9 < RC < 1.1 was obtained when OSEM (iteration: 10) was used when attenuation and scatter correction were applied. In this study, image quality of Cu-64 on Siemens Inveon PET was investigated. This data will helpful for the quantification of Cu-64 PET data.

Development of nationwide amplification map of response spectrum for Japan based on station correction factors

  • Maruyama, Yoshihisa;Sakemoto, Masaki
    • Earthquakes and Structures
    • /
    • 제13권1호
    • /
    • pp.17-27
    • /
    • 2017
  • In this study, the characteristics of site amplification at seismic observation stations in Japan were estimated using the attenuation relationship of each station's response spectrum. Ground motion records observed after 32 earthquakes were employed to construct the attenuation relationship. The station correction factor at each KiK-net station was compared to the transfer functions between the base rock and the surface. For each station, the plot of the station correction factor versus the period was similar in shape to the graphs of the transfer function (amplitude ratio versus period). Therefore, the station correction factors are effective for evaluating site amplifications considering the period of ground shaking. In addition, the station correction factors were evaluated with respect to the average shear wave velocities using a geographic information system (GIS) dataset. Lastly, the site amplifications for specific periods were estimated throughout Japan.

PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향 (Effect of MRI Media Contrast on PET/MRI)

  • 김재일;김인수;이홍재;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.19-25
    • /
    • 2014
  • PET/MRI에서는 MRI의 진단적 가치를 높이기 위해 T1 조영제를 사용하고 있다. PET의 감쇠 보정을 위해 T1 시컨스 계열인 VIBE DIXON은 조영제에 직접적으로 영향을 미치지만, 실제 ${\mu}-map$과 감쇠 보정된 PET 영상에는 큰 변화가 없었다. 그러므로 PET/MRI 검사시 조영제 사용은 PET 데이터 얻기 전 후 언제든 사용할 수 있을 것이다.

  • PDF

인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화 (Comparison of SUV for PET/MRI and PET/CT)

  • 김재일;전재환;김인수;이홍재;김진의
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가 (Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source)

  • 봉정균;김희중;박해정;권윤영;손혜경;윤미진;이종두;정해조
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.96-99
    • /
    • 2004
  • 본 연구는 전신 GSO PET 스캐너를 사용하여 Cs-137 투과 선원을 이용한 감쇠보정기법들을 평가하는 것이다. 이를 위하여, 4개의 모양이 다른 팬텀들을 사용하여 감쇠보정기법들을 검사하였다. 뇌영상을 위하여 256 mm의 시야가 사용되었고, 약 110MBq의 F-18 선원이 팬텀실험을 위해 사용되었다. 감쇠를 보정하기위해서, 방출선원이 팬텀에 주입된 후, Cs-137점선원의 투과 스캔 데이터가 획득되었다. 방출선원 데이터는 산란보정을 하였고, 4가지 종류의 감쇠보정기법을 이용하여 감쇠보정을 하였다. 재구성된 팬텀 영상들이 비교평가되었고, 임상 뇌영상은 핵의학 의사들이 평가를 하였다. 결과적으로 균일성 평가를 위한 원형팬텀의 영상에서, 측정감쇠보정기법을 이용시 가운데 부분이 떨어져 보였으나, 나머지 감쇠보정 기법들에서는 균일하게 보였다. 임상 뇌 데이터의 경우, 두개골에 대한 감쇠 효과를 볼 수 있었고, 두개골에 대한 감쇠보정이 적용되지 않은 영상에서는 인공산물이 발생하는 것을 보여주었다. 결론적으로, 정량적 뇌영상에 대한 정확도를 높이기 위해서, 두개골에 대한 감쇠보정이 적용된 개선된 감쇠보정 방법이 요구되어진다. 본 연구는 앞으로 Cs-137 점선원을 이용한 감쇠보정기법이 포함된 뇌 PET 영상 장치를 개선하는데 유용할 것으로 사료된다.

  • PDF

SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가 (Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT)

  • 김상규;김정열;박민수;조승현;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.3-7
    • /
    • 2014
  • CT를 기반으로 감쇠보정이 시행되는 SPECT/CT 검사에서는 금속 삽입물에 의한 선속경화현상으로 인접한 부위의 과대평가를 유발하며, 영상의 질을 저하시킨다. 이에 대해, 본 연구에서는 인공고관절이 삽입된 팬텀을 이용하여 감쇠보정지도의 매개변수 변화에 따른 금속 인공물이 SPECT/CT 영상에 미치는 영향을 알아보고자 한다. SPECT/CT 장비는 Siemens사의 Symbia T16을 사용하였다. SPECT/PET 팬텀에 인공고관절을 삽입하고, CT영상에서 Bright Streak 영역에 직경 17 mm의 구를 배후방사능 대비 8배가 되도록 Tc-99m을 채웠다. 이후 감쇠보정지도에서 Wide Beam Coefficient[수동모드(0.1~0.9), 자동모드]변화에 따른 열소와 배후방사능의 계수를 측정하였고, 고관절의 유무에 따라 Metal과 Non-Metal의 병소 대 배후방사능 비(Region to Background Ratio, RBR)를 산출 및 비교 분석하였다. 수동모드의 값이 증가할수록 Metal과 Non-Metal의 열소 계수는 증가하는 경향을 나타냈으며, 수동모드 0.4와 0.5에서 두 군과의 열소 계수비가 가장 일치하게 나타났다(수동모드 0.4=1.001, 0.5=0.999). 또한 $RBR^{Metal}$$RBR^{Non-Metal}$의 비는 자동모드에서 1.135이였고, 수동모드 0.4와 0.5에서 통계적으로 유의한 차이를 보이지 않았다(0.4=0.999, 0.5=1.028, p=0.78). 감쇠보정지도에서 Wide Beam Coefficient의 자동모드는 13.52% 과 보정 되는 것을 알 수 있었으며, 수동모드 중 0.4와 0.5에서 인공물에 의한 과 보정을 최소화 할 수 있었다. 이를 활용하여 환자에게 적용하기 위해서는 추가적인 연구가 이루어져야 할 것이며, 고관절전치환술 환자의 인공고관절 주변에서 금속 인공물에 의한 과 보정을 감소시켜 진단능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정 (Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction)

  • 최준영;우상근;최용;최연성;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.49-53
    • /
    • 2007
  • 목적: CT를 사용한 측정감쇠보정(measured attenuation correction; CT-MAC) PET 영상은 $^{68}Ge$을 사용한 분할감쇠보정(segmented attenuation correction; Ge-SAC) PET 영상보다 섭취값이 높은 것으로 알려져 있다. 이 연구에서는 정상인과 암으로 진단된 또는 암이 의심되는 환자를 대상으로 $^{18}F-FDG$ PET을 시행하고, 감쇠보정방법을 달리하여 각각 4가지 PET 영상을 얻고 이를 서로 정량적으로 비교하였다. 대상 및 방법: 5명의 정상인(남:여=4:1; 평균나이, $29.4{\pm}2.5$세)과 35명의 환자(남17, 여18; 평균나이 $52.7{\pm}15.2$세)를 대상으로 $^{18}F-FDG$ PET을 시행하였다. 먼저, CT 영상(140 KeV, 80 mAs)을 얻은 뒤 방출영상(5 min/bed)과 $^{68}Ge$ 투과영상(3 min/bed)을 차례로 얻었다. Ordered subsets expectation maximization (28 subsets, 2 iterations) 영상재구성법과 CT-MAC, CT-SAC, Ge-MAC, Ge-SAC의 4가지 감쇠보정방법을 사용하여 4가지 PET 영상을 얻었다. 정상인군에서는 대표적인 정상조직의, 환자군에서는 비정상적인 섭취를 보이는 병소의 SUV를 구하고, 이를 서로 비교 하였다. 결과: 정상인 군에서 CT-MAC 사용하여 감쇠보정한 PET 영상의 18개 정상조직의 SUV는 나머지 3가지 종류의 PET 영상에 비하여 모두 유의하게 높았다($3.1%{\sim}4.1%$; p<0.001). 환자군에서는 총 145개 병소의 국소 FDG 섭취증가 병변이 발견되었다. CT-MAC 사용한 PET 영상의 SUV 값은 나머지 3가지 PET 영상에 비하여 모두 유의하게 높았다($2.4%{\sim}5.1%$; p<0.001). Ge-MAC 사용한 PET 영상의 SUV 값은 CT-SAC와 Ge-SAC 사용한 PET 영상에 비하여 유의하게 높았다(p<0.001). 그러나, CT-SAC와 Ge-SAC PET 영상사이의 SUV에는 유의한 차이가 없었다. 폐병변에서는 감쇠보정방법사이에 섭취값이 유의한 차이가 없는 반면, 뼈병변에서는 이러한 차이가 가장 컸다($3.8%{\sim}9.6%$; p<0.01). 결론: $^{18}F-FDG$ PET 영상에서 섭취값은 CT-MAC로 감쇠보정을 했을 때에 가장 높다. CT 감쇠보정 및 MAC 사용, 2가지 모두가 이 차이에 기여했을 것이며, 이 중 MAC 사용이 더 크게 작용한 것으로 보인다. 감쇠보정방법이 다른 PET 영상들사이의 섭취값을 비교할 때는 이러한 차이를 고려해야 할 것이다.

PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System)

  • 손혜경;;권윤영;봉정균;정해조;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.100-103
    • /
    • 2004
  • 본 연구에서는 PET/CT시스템에서 CT영상을 이용한 감쇠 보정 시 조영제가 PET영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다. 모의실험을 위해 인체 기관 중 간을 가진 수학적 방출 스캔 맵과 투과 스캔 맵을 각각 만들었다. 간에서 조영제가 비 균일하게 증강된 투과 스캔 맵, 간에 조영제의 증강이 있는 투과스캔 맵과 없는 투과 스캔 맵, 간에 있는 종양에 조영제의 hypo-attenuating이 있는 투과 스캔 맵, 그리고 각각의 다른 조영제의 감쇠 정도를 가지는 간을 구현한 투과 스캔 맵을 각각 만들고 이를 이용하여 방출 영상을 감쇠 보정하였다. 팬텀실험을 통해 조영제의 농도에 따라 감쇠 정도가 달라짐을 확인하였다. 모의실험을 통해 감쇠 보정된 방출 영상이 조영제에 의해 영향을 받고, 또한 인공산물이 발생할 수 있음을 확인하였다. 따라서 조영제와 같은 물리적 인자가 감쇠 보정에 미치는 영향을 충분히 이해하고 정량적 분석 또는 진단 등에 고려하여야 할 것으로 생각한다.

  • PDF