• 제목/요약/키워드: Attenuation artifact

검색결과 29건 처리시간 0.643초

골격외 종양 환자에서 냉소 골전이와 유사하게 보인 잔류 바리움에 의한 광자 결손 (Photon Defects due to Residual Barium in the Colon Simulating Cold Bone Metastasis in Two Patients with Extraskeletal Cancer)

  • 임석태;김민우;손명희
    • 대한핵의학회지
    • /
    • 제36권5호
    • /
    • pp.314-316
    • /
    • 2002
  • One of common causes of cold defects on bone scintigraphy is an attenuation artifact. Cold defects can be produced by belt buckles, buttons, earring, necklaces, or other metal objects. Cold lesions in the abdomen are also produced by retained barium in the gastrointestinal tract after recent barium studies. We observed artifacts due to retained barium in the colon on bone scintigraphy, which simulated cold bone metastases in two patients with extraskeletal cancer.

32채널 뇌파 및 뇌유전발전위 Mapping 시스템 (32-Channel EEG and Evoked Potential Mapping System)

  • 안창범;박대준
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.179-188
    • /
    • 1996
  • A clinically oriented 32-channel electroencephalogram (EEG) and evoked potential (EP) mapping system has been developed EEG and EP signals acquired from 32-channel electrodes attached on the heroid surface are amplified by a pre-amplifier which is separated from main amplifier and is located near the patient to reduce signal attenuation and noise contamination between electrodes and the amplifier. The amplified signals are further amplified by a main amplifier where various filtering and gain contr61 are achieved An automatic artifact rejection scheme is employed using neural network-based EEG and artifact classifier, by which examination time is substantially reduce4 The continuously measured EEG sigrlals are used for spectral mapping, and auditory and visual evoked potentials measured in synchronous to the auditory and visual stimuli are used for temporal evoked potential mapping. A user-friendly graphical interface based on the Microsoft Window 3.1 is developed for the operation of the system. Statistical databases for comparisons of group and individual are included to support a statistically-based diagnosis.

  • PDF

Iterative Metallic Artifact Reduction 알고리즘 적용 CT 재구성영상의 CT Number 변화율 분석 (The Analysis of CT Number Rate of Change of Applying The Iterative Metallic Artifact Reduction Algorithm for CT Reconstruction Image)

  • 김현주;윤준
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.84-91
    • /
    • 2017
  • 본 연구는 컴퓨터 단층촬영 영상에서 제거할 수 없는 의료용 고밀도 물질을 Somatom Definition Flash(Siemens, Enlarge, Germany.)와 GE 64-MDCT (Discovery 750 HD, GE HEALTHCARE, Milwaukee, USA.)스캔 후 획득한 팬텀영상 데이터와 이미 촬영된 Raw 데이터영상을 이용하여 IMAR 알고리즘과 MAR 알고리즘 적용 및 재구성한 후 CT 재구성영상의 CT Number 변화율을 정량적으로 분석하였다. 그 결과 팬텀영상의 모든 의료용 고밀도 물질은 IMAR 알고리즘과 MAR 알고리즘 적용 시 CT Number의 변화와 영상의 차이가 있는 것으로 나타났지만(p<0.05). Stainless Steel 재질은 Black streak artifact에서 MAR 또는 IMAR 알고리즘 적용 시 재구성 영상의 변화와 CT Number의 변화차이가 없는 것으로 분석되었다(p>0.05). 또한 이미 촬영된 Raw 데이터영상 분석결과 IMAR 알고리즘 적용 시 적용 전에 비하여 영상 CT Number 변화가 있어, IMAR 알고리즘 적용은 Attenuation deviation에 영향을 미치는 것을 알 수 있었다. 이 결과를 바탕으로 향후 Implant시술 후 추적 CT검사 시 수술부위 및 주변조직의 상태를 관찰하는데 유용할 것으로 사료된다.

PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성 (Evaluation of Average CT to Reduce the Artifact in PET/CT)

  • 김정선;남기표;박승용;류재광;차민경
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.3-7
    • /
    • 2010
  • 종양학에서 암의 진단, 병기 결정, 재발 판정, 그리고 치료에 대한 반응의 평가에 PET/CT의 유용함은 이미 인정되고 있다. 그런데 크기가 작거나 폐의 기저 부위, 혹은 간의 상부에 위치한 종양일수록 호흡으로 인한 위치 변위와 왜곡의 정도가 크며 PET영상의 SUV에도 영향을 미치게 된다. 따라서 정상 호흡 상태에서 얻어지는 PET 또는 CT영상을 토대로 방사선 치료를 하게 되면 치료해야 할 표적이 치료 범위에서 벗어나거나 정상 조직에 과도한 방사선이 조사될 수 있으므로 치료율이 낮아지거나 방사선에 의한 부작용이 증가할 수 있다. 본 논문의 목적은 호흡에 의한 인공산물을 최소화하고 보다 정확한 SUV 측정을 위해 ACT를 이용한 감쇠 보정 방법을 적용하여 그 유용성을 평가하고자 함이다. 하 흉부에 종양이 있는 13명의 환자를 대상으로 Discovery STE8 PET/CT스캐너를 사용하여 두 가지의 PET/CT영상을 얻었다. HCT를 사용한 감쇠 보정 영상과 ACT를 사용한 감쇠 보정 영상에서 측정한 인공물의 크기와 $SUV_{max}$를 비교 분석하였다. 인공물은 모든 환자의 하 흉부의 백색 음영 영역을 측정하여 평가하였다. $SUV_{max}$는 주요 종양의 $SUV_{max}$를 측정하여 평가하였다. 분석 프로그램은 Advantage Workstation v4.3을 사용하였다. 환자에게 7.4 MBq (0.2 mCi)/kg의 $^{18}F$-FDG를 투여한 1시간 뒤 스캔하였다. 방출 스캔은 3 min/bed로 스캔하였다. HCT 보정 영상과 비교하여 ACT 보정 영상에서 인공산물의 크기가 눈에 띄게 줄어든 것을 관찰할 수 있었다. 하 흉부의 저 보정으로 인한 인공산물 크기는 ACT 보정 영상과 HCT 보정 영상 각각 $1.5{\pm}3.5$ cm과 $13.4{\pm}4.2$ cm를 나타냈다. 주요 병소의 $SUV_{max}$의 변화는 ACT 보정 영상이 HCT 보정 영상보다 눈에 띄게 상승하였다. ACT 보정 영상에서 HCT영상과 비교하여 tumor의 $SUV_{max}$가 평균 $5.3{\pm}3.9%$ 상승하였다. 가장 큰 차이를 보인 종양은 lung의 lower lobe에 있는 종양으로 $SUV_{max}$ 7.7에서 $SUV_{max}$ 8.7로 13% 상승하였다. ACT를 이용한 감쇠 보정 영상은 하 흉부의 인공산물을 눈에 띄게 줄일 수 있어 보다 정확한 병소의 SUV를 측정 및 방사선 치료 범위 설정에 도움이 될 수 있을 것이다. 또한 ACT 기법은 병소가 횡격막 부근에 있는 환자의 경우 폐와 간의 경계를 보다 정확히 구분할 수 있어 판독시 도움이 될 수 있을 것이라고 판단된다. 추가 ACT 촬영에 의한 피폭 선량이 증가하는 점을 고려하여 적용한다면 임상적으로 유용한 효과가 있다고 사료된다.

  • PDF

I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용 (The Evaluation of Images with Various Filters in I-131 SPECT/CT)

  • 김하균;김수미;우재룡;오소원;이재성;김유경
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.62-68
    • /
    • 2014
  • 치료 후 I-131 SPECT/CT는 잔류 갑상선 위치확인 및 전이유무를 판단하기 위하여 시행된다. 잔류 갑상선에 집적이 심한 경우 영상은 ringing artifact에 의하여 왜곡된다. 본 연구는 ringing artifact를 제거하고 영상의 질을 향상시키기 위한 적절한 post-filter의 적용에 대하여 제시하고자 한다. 본 실험은 hollow sphere와 아크릴통으로 구성된 phantom을 사용하여 SPECT/CT Discovery 670 (GE Healthcare, USA) 장비로 수행하였다. I-131용액을 hollow sphere에 184, 46, 9.2, 2.3 MBq/cc, 아크릴통에 46 kBq/cc을 각각 주입하였고 sphere 대 background의 비를 4000:1, 1000:1, 200:1, 50:1로 설정하였다. 데이터는 다음과 같은 조건으로 획득하였다(HEGP collimator 사용, Attenuation collection 적용, scan time 40 secs/frame, step angle 6도, scan mode non circular, evolution 적용과 미적용). 획득된 데이터는 OSEM (iteration 2, subset 10) 방식으로 재구성하였다. Post-filer의 사용에 따른 이미지의 변화를 보기 위해 3가지의 다른 post-filer들이 사용되었다(butterworth filter cut-off: 0.38, 0.43, 0.48, 0.53, 0.58, hanning filter cut-off: 0.8, 0.85, 0.9, 0.95, 1, gaussian FWHM: 3, 3.4, 4, 4.5, 5). 각각의 데이터는 MRIcro를 사용하여 contrast ratio, background variability를 분석하였고 e.soft ROI tool을 사용하여 FWHM값을 구하였다. Evolution을 적용한 경우, 모든 결과에서 contrast ratio값이 높게 나타났다. Evolution을 적용하지 않은 경우 star artifact 등 왜곡이 발생하였고 영상의 질이 현저히 낮아짐을 확인할 수 있었다. 4000:1, 1000:1, 200:1의 경우, butterworth filter 사용 시 ringing artifact가 발생하였으며 cut-off값이 커질수록 artifact가 감소하였다. Hanning filter를 사용한 경우 ringing artifact는 발생하지 않았다. Contrast ratio와 FWHM값이 butterworth filter나 hanning filter 적용 시 우수하였다. Gaussian filter경우 contrast ratio와 FWHM값에서 저조한 결과를 얻을 수 있었다. 50:1의 경우, 모든 경우에서 ringing artifact가 발생하지 않았다. Butterworth filter를 적용한 경우 가장 높은 contrast ratio와 가장 우수한 FWHM값을 나타내었다. 본 논문을 통하여 I-131 SPECT에서 ringing artifact가 발생 할 경우(thyroid remnant를 포함) hanning filter를 사용하여 영상을 재구성하고, ringing artifact가 발생하지 않을(remnant thyroid를 포함하지 않음) 경우 butterworth filter를 사용하여 재구성하는 것이 바람직하다는 사실을 알 수 있었다.

  • PDF

Characteristics of Magnetic Resonance-Based Attenuation Correction Map on Phantom Study in Positron Emission Tomography/Magnetic Resonance Imaging System

  • Hong, Cheolpyo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.189-193
    • /
    • 2020
  • An MR-based attenuation correction (MRAC) map plays an important role in quantitative positron emission tomography (PET) image evaluation in PET/magnetic resonance imaging (MRI) systems. However, the MRAC map is affected by the magnetic field inhomogeneity of MRIs. This study aims to evaluate the characteristics of MRAC maps of physical phantoms on PET/MRI images. Phantom measurements were performed using the Siemens Biograph mMR. The modular type physical phantoms that provide assembly versatility for phantom construction were scanned in a four-channel Body Matrix coil. The MRAC map was generated using the two-point Dixon-based segmentation method for whole-body imaging. The modular phantoms were scanned in compact and non-compact assembly configurations. In addition, the phantoms were scanned repeatedly to generate MRAC maps. The acquired MRAC maps show differently assigned values for void areas. An incorrect assignment of a void area was shown on a locally compact space between phantoms. The assigned MRAC values were distorted using a wide field-of-view (FOV). The MRAC values also differed after repeated scans. However, the erroneous MRAC values appeared outside of phantom, except for a large FOV. The MRAC map of the phantom was affected by phantom configuration and the number of scans. A quantitative study using a phantom in a PET/MRI system should be performed after evaluation of the MRAC map characteristics.

PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System)

  • 손혜경;;권윤영;봉정균;정해조;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.100-103
    • /
    • 2004
  • 본 연구에서는 PET/CT시스템에서 CT영상을 이용한 감쇠 보정 시 조영제가 PET영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다. 모의실험을 위해 인체 기관 중 간을 가진 수학적 방출 스캔 맵과 투과 스캔 맵을 각각 만들었다. 간에서 조영제가 비 균일하게 증강된 투과 스캔 맵, 간에 조영제의 증강이 있는 투과스캔 맵과 없는 투과 스캔 맵, 간에 있는 종양에 조영제의 hypo-attenuating이 있는 투과 스캔 맵, 그리고 각각의 다른 조영제의 감쇠 정도를 가지는 간을 구현한 투과 스캔 맵을 각각 만들고 이를 이용하여 방출 영상을 감쇠 보정하였다. 팬텀실험을 통해 조영제의 농도에 따라 감쇠 정도가 달라짐을 확인하였다. 모의실험을 통해 감쇠 보정된 방출 영상이 조영제에 의해 영향을 받고, 또한 인공산물이 발생할 수 있음을 확인하였다. 따라서 조영제와 같은 물리적 인자가 감쇠 보정에 미치는 영향을 충분히 이해하고 정량적 분석 또는 진단 등에 고려하여야 할 것으로 생각한다.

  • PDF

인간의 시각특성에 의거한 디지털 흉부 x-선 영상의 처리 기법 (A New Image Processing Method for Digital Chest Radiographs based on Human Visual System)

  • 김종효;박광석;민병구;임정기;한만청;이충웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.42-47
    • /
    • 1990
  • In this paper, a new adaptive image processing method based on human visual system has been presented. The basic idea behind the proposed method is to improve the efficiency of the information transfer channel regionally by manipulating the displayed image in order to compensate the regional inefficiency of the information transfer channel. The proposed method consists of two parts; the first part reallocates pixel values corresponding to high X-ray attenuation to that of more intense X-ray exposure by multiplying the pixel values with the local adaptive multiplcation factor, and the second part adjusts the pixel values of dark area of displayed image such as overexposed lung area to be more bright. The processed image with the proposed method shows significantly increased visibility of mediastinal and subdiaphramatic area, and also the lung area of over exposed case without any artifact.

  • PDF

간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가 (Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE)

  • 차은선;홍건철;박훈;최춘기;석재동
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.67-70
    • /
    • 2013
  • 급증하는 간세포암 환자에게 간동맥 화학 색전술은 효과적인 중재적 시술 방법 중 하나이다. 이때 PET/CT 검사는 색전 후 잔존 암세포의 존재 및 전이여부와 예후를 판단하는데 중요한 역할을 한다. 한편 간동맥 화학 색전술에 사용되는 색전물질인 Lipiodol은 PET/CT 검사에서 인공물을 생성하고 정량평가에 영향을 준다. 이에 본 연구는 Lipiodol이 영상에 미치는 영향의 정도를 방사능 값과 백분율 오차로 평가하고자 하였다. 1994 NEMA Phantom에 Lipiodol과 Teflon, 물을 세 개의 삽입물에 넣고 나머지 부분을 배후 방사능 $20{\pm}10MBq$를 주입하고 충분히 섞은 후 2분 30초/bed data를 획득 하였다. 재구성 방법은 반복 영상 재구성법으로 반복횟수 2회, 부분 집합 수 20을 적용하였으며, Lipiodol과 Teflon, 물, 인공물 발생부위, 배후 방사능에 관심영역을 설정하고 방사능 값과 백분율 오차를 산출 하여 비교하였다. 방사능 값은 Teflon, 물, Lipiodol, 삽입물 사이 인공물 발생 부위, 배후 방사능 부위에서 각 영역 중 방사능 값은 $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$(P<0.05)으로 통계적으로 유의한 차이를 보였다. 백분율 오차가 Lipiodol에서 물에 비해 118%, 배후 방사능에 비해서 52%, Teflon에 비해 180%의 차이가 있었다. Lipiodol을 주입한 후 검사에서 감약 보정의 영향을 받아 오차로 인한 방사능 농도 값이 다른 삽입물에 비해 현저히 높고 배후 방사능보다는 작다는 것을 알 수 있었다. 따라서 Lipiodol과 같은 조영 물질을 사용한 검사에서는 인공물에 대한 영향을 고려해야 하며 임상에서는 감약 보정을 적용하지 않은 영상을 참고해서 검사가 이루어 질 수 있도록 해야 한다.

  • PDF

PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석 (A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests)

  • 윤선희;김양중;강영직;박수영;김호신;류형기
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF