• Title/Summary/Keyword: Attachment position

Search Result 110, Processing Time 0.037 seconds

A Study on Motion Control and Kinematics Analysis of Articulated Manipulator Attachment for Excavator (포크레인용 다관절 매니퓰레이터 어태치먼트 운동학 해석 및 모션제어)

  • Kim, Hee-Jin;Kim, Sang-Hyun;Jang, Ki-Won;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.807-819
    • /
    • 2019
  • In this paper, it is proposed a new approach to motion control and kinematics analysis of articulated manipulator attachment with five degree of freedom for excavator. Unlike the well-established theory for the control of linear systems, there is little general control theory relatively for a robust control of nonlinear systems. The control technique is essential for providing a stable and robust performance for application of articulated manipulator control. The proposed control algorithm is one of robust control methods based on error informations of the position and velocity error informations using stability analysis of dynamic model. Through simulation test, the proposed control scheme is illustrated to be a efficient control technique for real-time control.

A STUDY ON THE CHANGES OF MR SIGNAL INTENSITY OF POSTERIOR ATTACHMENT OF THE TEMPOROMANDIBULAR JOINT (악관절 후방부착부에 있어서 MRI 신호변화에 대한 고찰)

  • Jung, Joo-Sung;Huh, Won-Shil;Chung, Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.1
    • /
    • pp.93-107
    • /
    • 1997
  • Magnetic resonance imaging has been used in the temporomandibular joint(TMJ) primarily to define morphology and positional relationship of associating structures. This report examines signal intensity characteristics of the posterior attachment as they related to the severity of internal derangement. Fifty six joints in 35 patients with a history of TMJ dysfunction were imaged writ MR using $T_1$-weighted spin echo sequence. According to disk position, ability to reduction, and the presence of osteoarthritis, the joints were categorized into three groups. A group 1 was anterior disk displacement with reduction; a group 2 was anterior disk displacement without reduction; a group 3 was anterior disk displacement without reduction and condyle had osteoarthritic change. The control group was determined by the clinical absence of any signs or symptoms of current or past TMJ pain and dysfunction. Calculated the relative value of MR signal intensity in posterior attachment and disk to cerebral cortex of temporal lobe by means of computer program, we have compared them with each groups. The result showed statistically little significant difference of disk signal intensity among each groups. but, signal intensity from posterior attachment in group 2 and 3 were significantly(p<0.05) decreased than control group. this might reflect an fibrosis or hyalinization of posterior attachment, which was part of remodeling process that occurs in disk displacement without reduction. However, this study could not demonstrate histologic confirmation of the decreased signal intensity in the posterior attachment. So, further investigation could be needed to understand the association between them.

  • PDF

Development of Smart Tape Attachment Robot in the Cold Rolled Coil with 3D Non-Contact Recognition (3D 비접촉 인식을 이용한 냉연코일 테이프부착 로봇 개발)

  • Shin, Chan-Bai;Kim, Jin-Dae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1122-1129
    • /
    • 2009
  • Recently taping robot with smart recognition function have been studied in the coil manufacturing field. Due to the difficulty of 3D surface processing from the complicated working environment, it is not easy to accomplish smart tape attachment motion with non-contact sensor. To solve these problems the applicable surface recognition algorithm and a flexible sensing device has been recommended. In this research, the fusion method between 1D displacement and 3D laser scanner is applied for robust tape attachment about cold rolled coil. With these sensors we develop a two-step exploration and the smart algorithm for the awareness of non-aligned coil's information. In the proposed robot system for tape attachment, the problem is reduced to coil's radius searching with laser displacement sensor at first, and then position and orientation detection with 3D laser scanner. To get the movement at the robot's base frame, the hand-eye compensation between robot's end effector and sensing device should be also carried out respectively. In this paper, we examine the auto-coordinate transformation method in the calibration step for the real environment usage. From the experimental results, it was shown that the taping motion of robot had a robust under the non-aligned cold rolled coil.

POSITION RECOGNITION AND QUALITY EVALUATION OF TOBACCO LEAVES VIA COLOR COMPUTER VISION

  • Lee, C. H.;H. Hwang
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.569-577
    • /
    • 2000
  • The position of tobacco leaves is affluence to the quality. To evaluate its quality, sample leaves was collected according to the position of attachment. In Korea, the position was divided into four classes such as high, middle, low and inside positioned leaves. Until now, the grade of standard sample was determined by human expert from korea ginseng and tobacco company. Many research were done by the chemical and spectrum analysis using NIR and computer vision. The grade of tobacco leaves mainly classified into 5 grades according to the attached position and its chemical composition. In high and low positioned leaves shows a low level grade under grade 3. Generally, inside and medium positioned leaf has a high level grade. This is the basic research to develop a real time tobacco leaves grading system combined with portable NIR spectrum analysis system. However, this research just deals with position recognition and grading using the color machine vision. The RGB color information was converted to HSI image format and the sample was all investigated using the bundle of tobacco leaves. Quality grade and position recognition was performed through well known general error back propagation neural network. Finally, the relationship about attached leaf position and its grade was analyzed.

  • PDF

Alteration in Surgical Technique of Tessier Classification Number 7 Cleft (Tessier 분류 7번 안면열의 수술방법의 변화)

  • Bae, Yong-Chan;Kang, Kyung-Dong;Kim, Kyoung-Hoon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.143-147
    • /
    • 2011
  • Purpose: A Tessier classification number 7 cleft is an uncommon malformation that results from a failure of mesenchymal fusion within the maxillary and mandibular prominences of the 1st pharyngeal arch. Many operative techniques of the number 7 cleft repair have been proposed to restore function and improve aesthetics. Fifteen patients underwent repair of a number 7 cleft over 13 years by a modification of the surgical Technique, and an appraisal of the operative outcome is reported herein. Methods: A retrospective review was conducted involving 15 patients with number 7 clefts who underwent surgery from 1996 to 2009. The changes in surgical technique included skin closure, attachment of the orbicularis oris muscle, and position of the repaired commissure; the changes were analysed with a review of the medical records and the outcomes of surgery were analysed via photographs. Specifically, the technique of skin closure was changed from the a Z-plasty to a linear closure, the orbicularis oris muscle overlapped attachment was replaced by a side-to-side approximation with horizontal mattress sutures, and the position of the repaired commissure was changed from 1 mm laterally to 1 mm medially in reference to the non-cleft side. Results: A Z-plasty caused additional cutaneous scarring, an overlapped attachment of the orbicularis oris muscle caused a thick oral commissure, and the repaired commissure migrated to the lateral side, so a 1 mm, laterally-positioned commissure caused asymmetry. The altered procedure included a linear skin closure, a side-to-side orbicularis oris muscle approximation, and a 1 mm, medially-positioned commissure, which together resulted in a good outcome. Conclusion: The altered procedure for repair of a number 7 cleft as described herein, yields a short scar, no functional problems with the orbicularis oris muscle, a thin oral commissure, and symmetry of the repaired commissure.

A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE FORCE DISTRIBUTION BY DISTAL EXTENSION PARTIAL DENTURES EMPLOYING ATTACHMENTS (Attachment를 이용한 후방연장 국소의치에 의한 압력분산에 관한 3차원 유한요소분석)

  • Shin, Sang-Wan;Ahn, Won-Jun;Jung, Yeon-Jin;Lee, Young-Soo;Shim, Kwang-Sup;Yoo, Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.878-887
    • /
    • 1998
  • Although attachments have been utilized for a retainer of removable prostheses during several decades, there is little information on the force distribution by the attachments. This study was undertaken to evaluate the stress patterns developed by partial dentures employing rigid attachments on the supporting structures. Four types of the mandibular removable partial dentures were designed depending upon the position of the rigid attachment and the existency of lingual bracing. Under 100N of vertical and 25N of lateral loads on the 1st and 2nd lower molar of partial denture, stress distribution patterns and displacement were analysed with three dimensional finite element method by ANSYS version 5.3. 1. The highest stresses were concentrated on the distal alveolar crest of posterior abutment and the second stresses on the apical region of posterior abutment in the models. 2. The greatest displacement were shown on the distal alveolar crest of posterior abutment and the second displacement on the distal alveolar crest of anterior abutment in the models. 3. There was little difference between the models with intraoral attachment and those with extracoronal attachment. 4. There was little difference between the models with and without the lingual bracing.

  • PDF

A Study on Quality Improvement of Cardiopulmonary Resuscitation Using Pad Attachment Glove (패드부착장갑을 이용한 심폐소생술 질 향상 연구)

  • Kim, Ye-Rim
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.289-295
    • /
    • 2019
  • This study was conducted to present effective CPR by identifying the usefulness of Pad Attachment Glove. The study subjects and data collection were conducted from 1 April 2019 to 30 April on Paramedic students of G university located in G-wide city and analyzed using the SPSS/Win 23.0. The study found that the chest compressions after wearing pad attachment gloves were higher in the areas of Chest Compressions total score, Number of chest compressions, chest recoil rate, hand position accuracy, CPR velocity than before wearing them. It was understood that pad attachment gloves improved the quality of chest compressions more than Hands-Only CPR. This will be used as a basic material for cardiopulmonary resuscitation education in the future, and is believed to contribute to devising a practical program.

Study of Practical Method for International 10~20 Electrode System (국제적인 10~20 전극시스템의 실용적인 방법에 관한 연구)

  • Kim, Sung-Hee;Lee, Ok-Kyoung;Kim, Dae Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Electroencephalography (EEG) is used for the diagnosis of epilepsy and testing the brain function. Clinical technologists are responsible for recording EEG without artifacts in accordance with the international 10~20 electrode system. Training on these techniques requires practical education. In the case of EEG, however, it is difficult for trainees to find the correct location of the electrode. Therefore, this study compared the time spent to locate the electrode attachment between traditional tape and the newly developed band. The time spent for sitting position patients using the band (196.7±61.8s) was 1084.3 s faster than the tape (1,281.0±457.4s) (P<0.001). Furthermore, the spend time spent for lying position patients using the band (200.2±49.3s) was 1217.7s faster than the tape (1417.9±482.3s) (P<0.001). Measurements using the band showed fewer differences due to various factors, such as position, practical experience, and gender. The newly developed band can locate the correct electrode attachment position quickly and efficiently, which has been a difficult problem in EEG practical education. In addition, this band is expected to be applied widely by new clinical technologists in the clinical field. Nevertheless, more study will be required to verify the accuracy of the location of the attaching electrode.

Matrix Attachment Regions (MARs) as a Transformation Booster in Recalcitrant Plant Species

  • Han, Kyung-Hwan
    • Korean Journal of Plant Tissue Culture
    • /
    • v.24 no.4
    • /
    • pp.225-231
    • /
    • 1997
  • For genetic engineering to be commercially viable, an efficient transformation system is needed to produce transgenic plane from diverse genotypes ("generalized protocol"). Development of such a system requires optimization of a number of components such as gene transfer agent, plant tissues competent for both regeneration and transformation, and control of transgene expression. Although several novel gene transfer methods have been developed for plane, a majority of stably transformed plane express the introduced genes at low levels. Moreover, silencing of selectable marker genes shortly after their incorporation into plant chromosomes may result in low recovery of transgenic tissues from selection. Matrix attachment regions (MARs) are DNA sequences that bind to the cell's proteinaceous nuclear matrix to form DNA loop domains. MARs have been shown to increase transgene expression in tobacco cells, and reduce position in mature transgenic plants. Flanking an antibiotic resistance transgene with MARs should therefore lead to improved rates of transformation in a diversity of species, and may permit recalcitrant species and genotypes to be successfully transformed. Literature review and recent data from my laboratory suggest that MARs can serve as a transformation booster in recalcitrant plant species.

  • PDF

Effects of Isokinetic Strength Exercise of the Hemiparetic Knee Joint on Lower Extremity Sensorimotor and Gait Functions in Patients With Chronic Stroke: Open Kinetic Chain Versus Closed Kinetic Chain

  • An, Chang-man;Roh, Jung-suk
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.49-60
    • /
    • 2019
  • Background: After stroke, in order to improve gait function, it is necessary to increase the muscle strength and to enhance the propriocetive function of the lower extremity. Objects: This study aimed to compare the effects of open kinetic chain (OKC) versus closed kinetic chain (CKC) isokinetic exercise of the hemiparetic knee using the isokinetic equipment on lower extremity sensorimotor function and gait ability in patients with chronic stroke. Methods: Thirty participants with chronic hemiplegia (> 6 months post-stroke) were randomly divided into 2 equal groups: CKC group and OKC group. Patients from both groups attended conventional physiotherapy sessions 3 times a week for 6 weeks. Additionally, subjects from the CKC group performed isokinetic exercise using the CKC attachment, while those from the OKC group performed isokinetic exercise using the OKC attachment. The isokinetic knee and ankle muscles strength, position sense of the knee joint, and spatiotemporal gait parameters were measured before and after interventions. Results: The knee muscles peak torque/body weight (PT/BW) and hamstring/quadriceps (H/Q) ratio significantly increased in both groups (p<.01). In particular, ankle plantarflexors PT/BW, position sense of the knee, gait velocity, and spatial gait symmetry significantly improved in the CKC group (p<.01, p<.05, p<.01, and p<.01, respectively). Conclusion: CKC isokinetic exercise can be an effective therapeutic intervention for the improvement of sensorimotor function of the lower extremity and gait functions, such as gait velocity and symmetry. CKC position in isokinetic strength training is effective to improve functional ability in patients with chronic stroke.