• 제목/요약/키워드: Atmospheric dispersion factor

검색결과 26건 처리시간 0.019초

시화공단 완충녹지대의 대기오염물질 저감 효과 분석 (Effect of Green Buffer Zone in Reducing Gaseous Air Pollutants in the Shiwha Industrial Area)

  • 송영배
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.90-97
    • /
    • 2006
  • The effects of a green buffer zone to protect a residential area from air pollution from industrial facilities and traffic was examined by analyzing the case of a green buffer zone in the Shiwha industrial complex. The green buffer zone is 175 m wide. The intent was to assess the dispersion patterns of atmospheric air pollutants and the reduction in concentration around the green buffer zone. To measure atmospheric sulfur dioxide$(SO_2)$ and nitrogen dioxide$(NO_2)$ concentration, badge-type passive samplers were used and set up at 76 locations in order to measure the concentration of air pollutants with respect to the spatial dispersion. The weighted mean values of $SO_2\;and\;NO_2$ concentration were $3\~57 ppb\;and\;18\~62 ppb$ and the differences among the green buffer zone, the industrial area and the residential areas were $0.7\~1.1 ppb$. Mean values of atmospheric concentrations of $NO_2$ were similar in industrial and, residential areas and the green buffer zone. Results of the study show that the effect of the green buffer zone on reducing the dispersion of air pollutants was very low. This study also recommends that micro-climate, i.e., wind direction should be considered as a factor for planning and design of green buffer zones.

Dose analysis of nearby residents and workers due to the emission accident of gaseous radioactive material at the spent resin mixture treatment facility

  • Jaehoon Byun;Seungbin Yoon;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4543-4553
    • /
    • 2023
  • The dose from a possible accident at a microwave-based spent resin mixture treatment facility that was to be installed and operated at the Wolsong nuclear power plant was analyzed to evaluate the radiological safety prior to its installation and operation. The dose to which workers and nearby residents are likely to be exposed was calculated based on the atmospheric dispersion and deposition factors using the XOQDOQ code. The highest atmospheric dispersion factors were 1.349E-05 s/m3 (workers) and 1.534E-06 s/m3 (residents). The highest doses due to emissions from the mock-up tank before operation were 1.91E-06 mSv (workers) and 1.78E-07 mSv (residents). Even after 3 h of operation, emissions from the mock-up tank had the greatest impact ranging from 4.63E-08 to 1.24E-06 mSv (workers) and 2.74E-10 to 1.16E-07 mSv (residents), respectively. The doses were 7.09E-09-4.55E-07 mSv and 4.18E-11-4.25E-08 mSv at 4-5 h of operation, and the maximum doses after operation reached 5.69E-07 mSv and 5.31E-08 mSv for the workers and residents, respectively. Even at the exclusion area boundary (EAB), 4.76E-08-9.51E-07 mSv (annual dose:9.52E-05–1.90E-03 mSv/y) was below the dose limit of the EAB, and the safety of the facility installation inside the NPP was confirmed.

기상자료의 통계처리방법이 원자력발전소의 가상 사고시 단기 대기확산인자에 미치는 영향 (Influence of Statistical Compilation of Meteorological Data on Short-Term Atmospheric Dispersion Factors in a Hypothetical Accidental Release of Nuclear Power Plants)

  • 황원태;김은한;정해선;정효준;한문희
    • Journal of Radiation Protection and Research
    • /
    • 제37권3호
    • /
    • pp.116-122
    • /
    • 2012
  • 미국 원자력규제위원회(U. S. NRC)에서 개발한 PAVAN 프로그램을 사용하여 기상자료의 통계처리방법에 따른 원자력발전소의 수명기간 중 발생할 수 있는 가상 사고시 단기 대기확산인자 값의 영향을 분석하였다. 대기확산을 평가하기 위한 기본요소는 기상자료이며, PAVAN에서는 대기안정도에 대한 풍향과 풍속의 발생빈도를 나타내는 결합빈도분포자료를 사용하여 평가한다. 고리와 월성 원자력발전소 부지에서 2006~2010년까지 5년간 관측된 기상자료를 사용하여 풍속등급의 분류방법(U. S. NRC 권고와 균등발생빈도 분류방법)과 평가에 적용되는 기상자료의 통계처리기간(1년, 2년, 3년, 4년, 5년)에 따른 결합빈도분포자료를 작성하여 단기 대기확산인자를 평가하였다. 평가결과, 두 원자력발전소 부지 모두 풍속등급의 분류에 따른 단기 대기확산인자 값의 영향은 미미한 반면 평가에 적용되는 기상자료의 분석기간은 상대적으로 중요한 영향을 나타냈는데, 최대값과 최소값의 비는 1.5배 이상의 차이를 보였다.

건설현장의 공사장비에 의한 미세먼지 배출계수 평가 (Assessment of PM Emission Factors Made by Construction Machineries)

  • 이임학;이경빈;김진식;김신도
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.311-318
    • /
    • 2014
  • The goles of this study were that we calculated the difference between the emission factors currently used officially and the emission factors that calculated by atmospheric dispersion modeling results and actual field measurements of dust concentrations and that we investigated how we applied to the emission factors appropriate to the reality in Korea. At the results, we calculated the Business As Usual ambient dust concentration concerning U.S. EPA method emissions, and we thought that the emission reduction efficiency had to be 99.7% if the ambient dust concentration that measured in this study could be satisfied. In other words, U.S. EPA dust emission calculation method is very overestimated than reality, so it is important that our country obtain reliable construction site dust emissions estimation methods by continuous researches.

대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구 (The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources)

  • 전상기;이성철;박경선
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

인구ㆍ기상인자에 의한 원자력 발전소 부지 평가 (Nuclear Power Plant Site Evaluation Using Site Population-Meteorology Factor)

  • Byung Hwan Rho;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • 제14권1호
    • /
    • pp.17-21
    • /
    • 1982
  • 본 논문에서는 원자력발전소 부지의 안전성 평가 방법으로서 부지의 인구를 평가하는 USNRC의 SPF를 보다 발전시켜 정상 가동시나 사고시 방출되는 방사성 물질이 대기에로의 확산으로 인하여 주거 인구가 받는 영향을 고려하여 SPMF를 정의하고 고리 부지에 대한 SPF와 SPMF를 비교함으로써 SPMF모델의 타당성을 검토했다. 아울러 미국 주요 발전소와 국내 발전소 부지의 SPF를 비교하여 국내발전소 부지의 상대적 안전성을 평가했다.

  • PDF

Wind tunnel study of plume dispersion with varying source emission configurations

  • Wittwer, Adrian R.;Loredo-Souza, Acir M.;Schettini, Edith B. Camano;Castro, Hugo G.
    • Wind and Structures
    • /
    • 제27권6호
    • /
    • pp.417-430
    • /
    • 2018
  • The concentration fields in the proximities of a local gas emission source are experimentally analyzed in several combinations of wind incidences and source emissions. These conditions are determined by the plume buoyancy, emission velocity and incident flow wind speed. Concentration measurements are performed by an aspirating probe in a boundary layer wind tunnel. The analysis included the mean concentration values and the intensity of concentration fluctuations in a neutral atmospheric boundary layer flow. Different configurations are tested: an isolated stack in a homogeneous terrain and a stack with a bluff body in close proximity, located windward and leeward from the emission source. The experimental mean concentration values are contrasted with Gaussian profiles and the dilution factor is analyzed with respect to the empirical curves of the minimum dilution. Finally, a study on the plume intermittency is performed in a cross-sectional plane near the emission source. It is possible to highlight the following observations: a) plume vertical asymmetry in the case of an isolated emission source, b) significant differences in the dispersion process related to the relative location of the emission source and bluff body effects, and c) different probabilistic behavior of the concentration fluctuation data in a cross-sectional measurement plane inside the plume.

대기오염농도와 기상인자의 관련성 연구: 서울 광화문지점을 중심으로 (A Study on the Relationship of Air Pollution and Meteorological Factors : Focusing at Kwanghwamun in Seoul)

  • 신찬기;한진석;김윤신
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.213-220
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-variate analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year(January 1990 $\sim$ December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutant emission trend based upon heating fuel usage. Ozone has a good corrleation with solar radiation and relative humidity to have a closed relation with $O_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and $O_3$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emssion source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multilicative model with wind speed, only one variable.

  • PDF

장기간 대기오염 및 기상측정 자료 (2000~2009)를 이용한 PM10과 NO2의 강수세정 기여율과 바람분산 기여율의 정량적 추정연구 (Quantitative Estimation of Precipitation Scavenging and Wind Dispersion Contributions for PM10 and NO2 Using Long-term Air and Weather Monitoring Database during 2000~2009 in Korea)

  • 임득용;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.325-347
    • /
    • 2012
  • Long-term air and weather data monitored during the period of 2000 to 2009 were analyzed to quantitatively estimate the precipitation scavenging and wind dispersion contributions of ambient $PM_{10}$ and $NO_2$ in Korea. Both air pollutants and meteorological data had been respectively collected from 120 stations by the Ministry of Environment and from 20 weather stations by the Korea Meteorological Administrations in all parts of Korea. To stochastically identify the relation between a meteorological factor and an air pollutant, we initially defined the SR (scavenging ratio) and the DR (dispersion ratio) to separately calculate the precipitation and wind speed effects on the removal of a specific air pollutant. We could then estimate the OSC (overall scavenging contribution) and the ODC (overall dispersion contribution) with considering sectoral precipitation and wind speed probability density distributions independently. In this study, the SRs for both $PM_{10}$ and $NO_2$ were generally increased with increasing the amounts of precipitation and then the OSCs for $PM_{10}$ and $NO_2$ were estimated by 22.3% and 15.7% on an average in Korea, respectively. However, the trend of the DR was quite different from that of SR. The DR for $PM_{10}$ was increased with increasing wind speed up to 2.5 m/s and further the DR for $NO_2$ showed a minimum in the range of $1<WS{\leq}1.5$. The ODCs for $PM_{10}$ and $NO_2$ were estimated by 14.9% and 1.0% in Korea, respectively. Finally, we have also provided an interesting case study observed in Seoul.

인천 지역 LNG G/T발전소의 미세먼지 (PM10) 배출량 평가 및 주변 대기질 영향 분석 (PM10 Emission Estimation from LNG G/T Power Plants and Its Important Analysis on Air Quality in Incheon Area)

  • 공부주;박풍모;동종인
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.461-471
    • /
    • 2015
  • Base on emission factors derived from National Institute of Environmental Research, Particulate matter from combined cycle power plants (CCPPs) has been estimated to be a important source of $PM_{10}$. Generally there is no serious emission of particulate matter in CCPPs. because the fuel of them is natural gas. But emission gas after long shut down season has very high dust content. Therefore $PM_{10}$ emission rate is dependent on its operation mode. In this study, particulate dispersion study for new city near CCPPs complex has performed using CALPUFF model for three case. $PM_{10}$ concentration has big difference between normal operation and 2 case start-up condition after long shutdown. In normal operating conditions, daily $0.32{\sim}0.50{\mu}g/m^3$ influence on of the surrounding area. But when 1~2 aerobic high concentration discharged conditions, average concentration is higher about $9.2{\sim}34.1{\mu}g/m^3$ than normal operating conditions.