• Title/Summary/Keyword: Astigmatism Axis

Search Result 62, Processing Time 0.03 seconds

Optical System Design for a Head-up Display Using Aberration Analysis of an Off-axis Two-mirror System

  • Kim, Byung-Hyun;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.481-487
    • /
    • 2016
  • This study presents a new optical system for a combiner-type head-up display (HUD) with a cylindrical lens as an asymmetrical aberration corrector, instead of a freeform mirror. In the initial design process based on off-axial aberration analysis, we obtain an off-axis two-mirror system corrected for linear astigmatism and spherical aberration by adding a conic secondary mirror to an off-axis paraboloidal mirror. Thus, since the starting optical system for an HUD is corrected for dominant aberrations, it enables us to balance the residual asymmetrical aberrations with a simple optical surface such as a cylinder, not a complex freeform surface. From this design process, an optical system for an HUD having good performance is finally obtained. The size of the virtual image is 10 inches at 2 meters away from a combiner, and the area of the eye box is 130×50 mm2.

Alignment of Schwarzchild-Chang Off-axis Telescope with a Shack-Hartmann Wavefront Sensor and Sensitivity Table Method

  • Lee, Sunwoo;Park, Woojin;Kim, Yunjong;Kim, Sanghyuk;Chang, Seunghyuk;Jeong, Byeongjoon;Kim, Geon Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.79.1-79.1
    • /
    • 2019
  • The Schwarzchild-Chang telescope is a confocal off-axis two mirror telescope with D = 50 mm, F = 100 mm and FOV = 8 ° × 8 °. Unlike common off-axis telescopes, the mirrors of the Schwarzchild-Chang telescope share their focal points to remove the linear astigmatism. In this poster, we show the alignment process of the Schwarzchild-Chang telescope with wavefront measurement and the sensitivity table method. Wavefront is measured using the Shack-Hartmann sensor, and Zernike polynomials are obtained from measured wavefront. Sensitivity table method is to calculate alignment errors from the Zernike coefficients. As a result, we evaluate tilt, decenter, and despace of each mirror of linear astigmatism-free con-focal off-axis system.

  • PDF

Refractive Error in 7-9 Year-old Korea Children (7세부터 9세 사이의 한국인 어린이의 굴절 이상)

  • Kim, Douk-Hoon;Alberto, Mercedita O.
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.3
    • /
    • pp.203-208
    • /
    • 2014
  • Purpose. To analysis the refractive error in 7-9 year-old Korea children. Methods. From July 2013 to June 2014, two hundred eighty two subjects were performed in refraction test using the Auto-Refractometry. Results. The refractive error by spherical equivalent among all subjects was myopia 47.58%, emmetropia 42.35%, astigmatism 32.33%, and hyperopia 8.76%. Myopia was more common in female than males although the difference was not statically significant. The axis of astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5% There was a statistical significance between 7 year and 9 year of male in the spherical equivalent power(p=0.010). Also there was a statistical significance between 7 years and 9 years of female in the spherical equivalent power(p=0.036). However, there was not a statistical significance between male and female in spherical equivalent power(p>0.5). Conclusions. In this study, myopia was the most common refractive error. On the other hand, The prevalence of the axis of astigmatism was the with- the- rule. The spherical equivalent of refractive error was similar results between male and female. However The refractive error was different style with aging. these data suggested that the analysis of the refractive error at young children can provide the information of useful diagnosis for the correction of visual acuity.

Survey on the Refractive Status of Primary School Children with Subnormal Visual Acuity in Seoul (서울지역 초등학동 비정시안의 굴절상태에 대한 조사)

  • Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.65-69
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. This study was researched visual acuity test using objective and subjective methods. 1. The eye types were 90.3% positive for myopia, 3.1% for emmetropia, 4.9% hyperopia, 1.7% for mired astigmatism. 2. The abnormal refraction eyes were 58.6% positive for simple myopia, 29.9% for myopic compound astigmatism, 5.1% for my optic simple astigmatism and 1.9% for simple hyperopia, 1.9% for hyperopic compound astigmatism, 1.3% for hyperopic simple astigmatism, 1.3% for mixed astigmatism. 3. The axis of astigmatism were 85.7% for astigmatism with-the-rule, 9.3% for astigmatism against-the-rule, 5.0% for astigmatism oblique. 4. On total myopic spheric power. the -0.50

  • PDF

Design of Linear Astigmatism Free Three Mirror System (LAF-TMS) for Sky Monitoring Programs

  • Park, Woojin;Pak, Soojong;Chang, Seunghyuk;Kim, Sanghyuk;Kim, Dae Wook;Lee, Hanshin;Lee, Kwangjo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.88.1-88.1
    • /
    • 2017
  • We report a novel design of the "linear astigmatism-free" three mirror system (LAF-TMS). In general, the linear astigmatism is one of the most dominant aberration degrading image qualities in common off-axis systems. The proposed LAF-TMS is based on a confocal off-axis three mirror system, where higher order aberrations are minimized via our numerical optimization. The system comprises three pieces of aluminum-alloy freeform mirrors that are feasible to be fabricated with current single-point diamond turning (SPDT) machining technology. The surface figures, dimensions, and positions of mirrors are carefully optimized for a LAF performance. For higher precision-positioning mechanism, we also included alignment parts: shims (for tilting) and L-brackets (for decentering). Any possible mechanical deformation due to assembly process as well as 1-G gravity, and its influence on optical performances of the system are investigated via the finite element (FE) analysis. The LAF-TMS has low f-number and a wide field of view, which is promising for sky monitoring programs such as supernova surveys.

  • PDF

Analysis of refraction status on the Presbyopia in Korea (한국인 노안 굴절상태 분석)

  • Kim, Douk-Hoon;Lee, Min-Ho
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1337-1344
    • /
    • 2019
  • Purpose. This study was the analyze the refractive status of presbyopia in Korea. Methods. The subjects was from November 2018 to October 2019, two hundred thirty four subjects( 117 male subjects, 117 female subjects; from 40-year old to 88-year old ) were performed in refraction test using the Auto-Refraction(Speed -K model, Japan). The myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)≤-0.50 diopters, SE ≥+1.00 D, cylinder error ≥0.75 D and SE difference≥1.00 D between binocular eyes, respectively. Results. The refractive status by spherical equivalent among all subjects was myopia 61.43%, astigmatism 86.86%, emmetropia 19.18%, anisometropia 12.07%, and hyperopia 18.54. The prevalence of myopia and astigmatism were much more common in male. However, The hyperopia and astigmatism were much more common in female. The prevalence of spherical equivalent was much common from -0.50 diopter to -5.00 diopter. On the other hand, the prevalence of astigmatism and myopia was much more than hyperopia in all subjects. There was a statistical significance between OD and OS of the female and male in the spherical equivalent power(p<.000). However, there was not statical significant between female and male of OD and OS in the spherical equivalent power(p<.070). On the other hand, The prevalence of againest axis in astigmatism was more common in all subjects. In ADD power for the near vision correction, the female was much more diopter than male. Conclusions. These results suggested that the analysis of the refractive status on the presbyopia in Korea can give the useful diagnosis data for the correction of visual acuity at near distance.

The Clinical Study on Far Diatance Spectacles for Teen-age and Twenty-age (10대와 20대의 원용안경에 관한 임상적 연구)

  • Hong, Soo-Hak;Kim, Sang-Kun;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.149-154
    • /
    • 2002
  • This study is examined the difference between binocular spherical diopter and astigmatism diopter, spherical diopter, astigmatism diopter, and axis of astigmatism by sex and age with reference to the prescription of refraction for a total of 257 persons, 134 persons (male:78, female: 56)of teen-age and 123 persons of twenty-age who visit optical shop. Spherical correction diopter is mainly distributed to 280 eyes between -0.25D and -4.00D. And in astigmatism correction, for right astigmatism, 48 eyes(49.48%) are prescribed astigmatism diopter for a range of C-0.25~C-0.50D, 29 eyes(29.89%) has C-0.75~C-1.00D, 65 eyes(67.01%) has with the rule astigmatism. For left astigmatism, 43 eyes(42.57%) are prescribed astigmatism diopter of C-0.25~C-0.50D and 37 eyes(36.63%) has C-0.75C~1.00D, 73 eyes(72.27%) are shown with the rule astigmatism. And also each 108 persons(47.16%) and 28 persons(25.00%) are shown no difference between binocular spherical correction diopter and binocular astigmatism correction diopter, 94 eyes(39.49%) of teen-age and 104 eyes(42.27%) of twenty-age, male 119 eyes(41.90%) and female 79 eyes(34.34%) need correcting astigmatism. In pupillary distance, 165 persons mostly have 59~64mm.

  • PDF

Optomechanical Design and Vibration Analysis for Linear Astigmatism-Free Three Mirror System (LAF-TMS)

  • Park, Woojin;Lim, Jae Hyuk;Lee, Sunwoo;Hammar, Arvid;Kim, Sanghyuk;Kim, Yunjong;Jeong, Byeongjoon;Kim, Geon Hee;Chang, Seunghyuk;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.47.1-47.1
    • /
    • 2019
  • We report the design and vibration analysis for the optomechanical structures of Linear Astigmatism Free - Three Mirror System (LAF-TMS). LAF-TMS is the linear astigmatism free off-axis wide-field telescope with D = 150 mm, F/3.3, and FOV = 5.51° × 4.13°. The whole structure consists of four optomechanical modules. It can accurately mount mirrors and also can survive from vibration environments. The Mass Acceleration Curve (MAC) is adapted to the quasi-static analysis. Modal, harmonic, and random vibration analysis have been performed under the qualification level of the launch system. We evaluate the final results in terms of von Mises stress and Margin of Safety (MoS).

  • PDF

Ten-year Refractive Error and Astigmatism Changes in Korean Subjects (한국인의 10년간 굴절이상과 난시 축 변화)

  • Ha, Na-Ri;You, Jung-Kone;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.389-397
    • /
    • 2010
  • Purpose: This study was to investigate the changes of refractive error and astigmatism associated with age in Korean subjects between the ages of 6 and 80 years during 10-year period. Methods: 220 normal subjects (345 eyes) who visited ophthalmic clinic was recruited and followed for 10 years between 1999 and 2009, cycloplegic manifest refraction being performed annually. Visual acuity was tested on a Han's chart. Results: The mean 10-year change in the spherical equivalent refraction (SER) of age 6 to 10 years old and 10 to 20 years was -3.649D and -2.165D respectively. There was no change of refractive error in age 21 to 40 years. The myopic shift decreased with age from 41 up to 69 years but increased slightly in patients 70 years and older; the hyperopic shift showed the opposite trend. The distribution of refractive error over the 10 years in aged 6 to 10 and 11 to 20 years was shifted myopic. The incidence of medium (> -3.01D) to high myopia at age 6 to 10 years was 4.8% and after 10 years was 62.5%. The 10-year change of astigmatism axis was in "with the rule" direction for younger age group and in a "against the rule" direction for older subjects. Conclusions: This study has documented refractive error changes in Korean subjects and confirmed reported trends of myopic shift from age 6-20 years and hyperopic shift before age 70 years and a myopic shift thereafter. The axis of astigmatism turns to "against the rule" after 40's.

The Corneal Base Curve, Astigmatism, and Power of Women College Students (여대생들의 각막기본 곡률, 난시, 굴절력)

  • Kim, Douk-Hoon;Choi, Ho-Seong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The corneal structure and function changes somewhat with aging. We were performed the analysis of women college students on the base curve, power, and astigmatism axis of the cornea by keratometer. All women subjects were between the ages of 19 and 20 years. On the corneal base curve. the right eye of the ages of 19 was 7.64 mm in vertical and 7.81 mm in horizontal. But, the left eye was 7.65 mm in vertical and 7.83 mm in horizontal on the other hand, the right and left eye of the ages of 20 was 7.72 mm in vertical and 7.75 mm in horizontal. On the corneal diopter power, the right eye of the ages of 19 was 44.21 diopter in vertical and 43.32 diopter in horizontal. But, the left eye was 44.23 diopter in vertical and 43.24 diopter in horizontal. On the other hand, the right eye of the ages of 20 was 43.67 diopter in vertical and 43.62 diopter in horizontal. But, the left eye was 43.73 diopter in vertical and 43.6 diopter in horizontal. According to the corneal astigmatism axis style, the right eye of the ages of 19 have 83% positive for with the rule astigmatism, and 16% positive for against the rule astigmatism. But, the left eye of the ages of 19 have 86% positive for with the rule astigmatism, and 12% positive for against the rule astigmatism. On the other hand, the right eye of the ages of 19 have 56% positive for with the rule astigmatism, and 44 % positive for against the rule astigmatism. But, the left eye of the ages of 20 have 56% positive for with the rule astigmatism, and 41% positive for against the rule astigmatism. According to the diopter power of corneal astigmatism. The right eye of the ages of 19 have 36% positive for behind 1 diopter and left eye have 31%. But, the right and left eye of the ages of 20 have 37.5%. The right and left eye of the ages of 19 have 42% positive for 1 diopter, and the right eye of the ages of 20 have 34.4% positive for 1 diopter and the left eye have 43.8%. The right eye of the ages of 19 have 12% positive for 2 diopter and left eye have 22%. But, the right eye of the ages of 20 have 15.6% positive for 2 diopter and the left eye have 12%. The right eye of the ages of 19 have 4% positive for 3 diopter and left eye have 3%. But, the left eye of the ages of 20 have 3% positive for 3 diopter and the left eye have 6%. On the other hand, the right eye of ages of 19 have 6% positive over 4 diopter, and the left eye have 2%. But, the right eye of ages of 20 have only 9% positive over 4 diopter.

  • PDF