• Title/Summary/Keyword: Assistive device

Search Result 181, Processing Time 0.024 seconds

Influence of Four Types of Steering Assistive Devices on Driving Performance: Comparison of Normal and Disabled People with and without Driver's License (4가지 선회보조 장치가 운전 성능에 미치는 영향: 장애 유무와 운전면허 유무에 따른 비교)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.32-42
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of Healthy and disabled groups (with or without driver's license) to control steering wheel by using steering assistive devices in the driving simulator. The persons with partial loss of use of all four limbs have problems in operation of the motor vehicle because of functional loss to operate steering wheel. Therefore, if steering assistive devices for grasping the steering wheel are used to control the vehicle on the road in persons with disabilities, the disabled persons can improve mobility in their community life by driving a motor vehicle safely. Ten healthy subjects (with or w/o driver's license) and ten subjects with physical disabilities (with or w/o driver's license) were involved in this study to evaluate driving performance to operate steering wheel by using four types of steering assistive devices (Single-pin, V-grip, Palm-grip, Tri-pin) in driving simulator. STISim Drive 3 software was used to test the steering performance in four scenarios: straight road at low and high speed of vehicle (40 km/h and 80 km/h), curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA in order to compare the effects of two factors (type of steering assistive device and subject group) in the three dependent variables of driving performance (the lateral position of vehicle, standard deviation of lateral position representing the variation of the left and right movement of the vehicle and the number of line crossing). The mean values of the three dependent variables (lateral position, standard deviation of lateral position, the number of line crossing) of steering performance were statistically significantly smaller for the healthy or disabled groups with driver's license than the other groups without driver's license on the curved road at high speed of vehicle compared to low speed of vehicle.

Development of Walking Assistant Controller for Patients with Weakness in Cardiopulmonary System (심폐기능 허약자를 위한 보행보조장치 제어기 개발)

  • Kang, S.J.;Kim, G.S.;P, S.H.;Mun, M.S.;Sei, S.W.;Kim, J.K.;Ryu, J.C.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • Case of patients with weakness in cardiopulmonary system, other ambulatory function is normal, but oxygen supply function is problem. So they need reduce energy consumption for gait by assistance system. In this study, we designed and developed walking assistant device which helps flexion and extension of hip joint for cardiopulmonary patients. There are two motors, each at the left and right side of pelvis, providing torque to the hip joint. The target angle of the flexion and extension in the hip joint is set according to the normal gait. As a result, reduction of energy consumption was 14.8% by gait assistive device.

Suggest Improvement for Medical Device Made in Korea by the Investigation of Domestic Medical Device Percentage and Survey of Medical Device Users and Manager (국산 의료기기 사용률과 사용자 및 관리자 인식 조사를 통한 국산 의료기기 개선 방안)

  • Lee, Jyung Hyun
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • The Korean medical device industry has increased dramatically due to various investments in the domestic medical device industry and the introduction of new technologies, but the domestic medical device usage rate in great hospital is still low. In this paper, improvement point for domestic medical device was suggested by domestic medical device usage rate and user and manager's perception survey in great hospitals in Korea. To do this, a survey on the types of medical devices and domestic medical device usage rates were conducted at four national university hospitals in Korea. From this results, the priority survey medical devices were selected. Improvements of Korean medical devices were suggested by failure mode analysis and user awareness surveys for the priority survey medical devices.

A Comparative Analysis on the AAC Service Delivery System between the U.S. and Korea (미국과 한국의 AAC 서비스 전달체계 비교 분석)

  • Rhee, Kun Min;Yim, Sung-bin;Na, Da Yung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.99-105
    • /
    • 2017
  • The purpose of this study was to compare AAC service delivery system between Korea and U.S.A for appling effective 'AAC service delivery system. This delivery system complement the missing part in system of the current method and narrow blind area for system. The result of this research, increase suppling item of assistive communication device in public benefit and provide delivery system through construct infrastructure by assistive technology center, special education support center, developmental disorder support center, speech therapy center in each local area. Furthermore, assistive technology-related institute and academy develope training programs for human resources to delivery AAC service.

Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack (수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템)

  • Kang, So Myoung;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

A Study on the Usefulness of an Ankle Joint Examination Assistive Device using a 3D Printing (3D 프린터를 이용한 발목관절 검사 보조기구의 유용성연구)

  • Dong-Hee Hong;Eun-hye Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1099-1108
    • /
    • 2023
  • The mortise view radiography procedure is an ankle joint examination and observes the presence of trauma, sprain, or dislocation suspected in the ankle joint. The auxiliary equipment used during the mortise view radiography procedure can generate artifacts in the radiograph images and is not diverse enough to be custom-made for each patient; not cost-efficient. The purpose of this study is to create a custom assistive device to support mortise view radiography procedure. This study utilized 3D printing technology to create the mortise view radiography procedure assistive device (ShinHan Device; SHD). The lengths of the tibiotalar joint (TTJ), talar calcaneal joint (TCJ), and medial joint (MJ) were measured and evaluated by five researchers using both SHD and the prototype Hologic tool. The mean ranges were found to be 39.42-39.47 mm for TTJ, 31.41-31.57 mm for TCJ, and 21.21-21.23 mm for MJ while using SHD device. On the other hand, the measurements showed mean ranges of 39.73-39.79 mm for TTJ, 31.46-31.50 mm for TCJ, and 21.31-21.35 mm for MJ while using the Hologic tool. Based on this study results, the error ranges at all positions decreased by 24% for TTJ, 17% for TCJ, and 36% for MJ when using SHD device compared to the Hologic tool. Moreover, when SHD was used, it allowed for a highly reproducible examination posture (ICC = 0.99), and it enabled the acquisition of radiograph images without artifacts, which were present in the Hologic tool.

A Report of the Assistive Technology Service Operating System for the Disabled in Sweden (스웨덴 장애인 보조기구 제공 시스템에 대한 소고)

  • Choi, Young Soon
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.25-45
    • /
    • 2014
  • The present report aims to examine the assistive technology(AT) service operating system for the Disabled in Sweden, and will give it to NHIS(National Health Insurance Service) to manage of policy for AT service operating system. The user of AT is around 10% of the Disabled in Sweden which is introduced the AT service system to support the independence for the Disabled. To provide AT service, the role of the Ministry of Health(planning and regulation, controling Handisam and Hi as a subsidiary), County councils(providing and follow up medical AT service, operating AT service center) and Municipalities(providing general AT service) in Sweden is decentralized strictly. Specially, all the AT device is lent freely and recycled suitably for persons with Disabilities, moreover nurses, physical therapist and occupational therapist has a qualification for prescription of AT device . This finding will be the basis to improve Assistive Technology Operating System in Korea.

A Study on the Job Analysis of Assistive Product Specialist (복지용구 전문가 직무분석에 관한 연구)

  • Cho, Mi-Lim;Yang, Yeong-Ae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.319-329
    • /
    • 2017
  • As Korea is now an aging society, the demand and necessity of assistive products for senior citizens are increasing. On the other hand, their satisfaction with the assistive-product payment service is pretty low, so that the necessity of assistive-product specialists is newly rising. Therefore, it is important to establish a frame of assistive product specialist and clarify the duties. This study aimed to define and analyze the job of assistive-product specialists. This study was carried out from June 1, 2015 to February 10, 2016. After the literature consideration and analysis of the current status, a job analysis(plan) of assistive product specialists was drawn after the job of assistive product specialists was defined, and the duties, tasks, and task elements were analyzed by experts through an advisory conference. A Delphi method was conducted with five professional panels to verify the validity. For the job contents of assistive product specialists, 5 duties, 12 tasks, and 23 task elements were identified. The significance of this study was to establish the system and standard for assistive device specialists defining and analyzing the job of assistive product specialist. Through this study, it would be possible to secure the professionalism of an assistive-product specialist and qualitative improvement of an assistive-product payment service.

The Status of Accidents and Management for Electronic Assistive Devices among the Handicapped (장애인 전동보조기구 사고 및 관리현황에 관한 연구)

  • Kim, Deok-Ju;Lee, Hye-Jin;Yang, Yeong-Ae
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.223-234
    • /
    • 2016
  • Objectives : The purpose of this study was to investigate accident cases involving electronic assistive devices, to determine how these accidents can be avoided and to devise preventative instructions for the handicapped who use these devices. Methods : This study was carried out from July 20 to October 3, 2015. A consent-based survey was conducted via mail and mobile phones targeting 700 electronic assistive device users, of which questionnaires from 290 users were collected and used in the analysis. Results : Accidents involving electronic assistive devices were investigated, especially the causes of the accidents and accident prevention education, as well as the status of the electronic assistive devices. The most common accident types were collision and falling, and it was found that the victims of the accidents usually suffered severe injury to their lower limbs. Most users used electronic assistive devices every day but rarely wore a safety belt because of discomfort. There were more incidents of collision and falling for older aged handicapped users, and the injury rate to the lower limbs was highest in handicapped elderly aged 50 years or older. Conclusions : In order to prevent accidents with electronic assistive devices in the future, a or management organizations must prepare specific safety guidelines and manage these accidents.

A Cross-Sectional Survey for the Improvement of Self-Feeding: Focusing on Assistive Eating Devices (자립적 식사 향상을 위한 조사연구: 식사보조도구를 중심으로)

  • Lee, Young A;Choi, Yeon Suk;Lee, Kyung Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.37 no.2
    • /
    • pp.261-274
    • /
    • 2023
  • Purpose: This study aims to understand the current use of and demand for assistive eating devices. These device improve the self-feeding abilities in older adults. Methods: This study used a cross-sectional study design. Descriptive statistics were performed using SPSS 22.0 for Windows. The survey participant of 282 older people(47.7%), 42 family caregivers(7.4%), and 266 staff members(44.9%). Results: Whereas most of the older adults living in their home(87.3%) did not experience difficulty while eating, older adults residing in facilities(26.4%) expressed difficulty with the process of putting food into a spoon. The difference between the two groups was statistically significant(p<.001). Wile the older adults living in home considered assistive eating devices(34.5%) as the most important requirement for self-feeding, older adults in facilities considered receiving help(39.3%) as their biggest requirement(p<.009). Older adults, family caregivers, and nursing home staff were not familiar with assistive eating devices and were not aware of their necessity. Conclusion: The study could help increase awareness about assistive eating devices and the importance of self-feeding in research and nursing educational settings. Improvement in self-feeding ability may future enhance the daily quality of life of older adults.