• Title/Summary/Keyword: Assistive Technology

Search Result 449, Processing Time 0.02 seconds

Development of a Data Glove for Rehabilitation Robot for Upper Extremity Paralysis (상지마비 재활훈련로봇용 데이터글로브의 개발)

  • Park, C.Y.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.45-49
    • /
    • 2009
  • This paper proposes a data glove for a rehabilitation robot interface for the upper extremity paralysis. The designed data glove uses seven flexible sensors so as to measure the flexion angles of fingers and wrist. We verified the performance of the data glove using a 3D graphic interface developed. The experimental results show that the proposed data glove is feasible to sense hand motions and applicable to the robot interface.

  • PDF

Study on a test method for the endurance of myoelectric hand prosthesis (근전의수의 내구성 시험방법에 대한 연구)

  • Choi, K.W.;Mun, M.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2011
  • This paper propose the test method for a performance of the myoelectric hand prosthesis(MHP) controlled according to the myoelectric signal generated in the human muscle. The MHP consists of a mechanical hand, a surface myoelectric sensor(SMES) for a measuring myoelectric signal, a control system and a charging battery. The two commercialized MHP is tested for the grip endurance property. The test results is not difference a noise and a grip force. The proposed test method is proved the reliability of MHP by the endurance test.

Development of Finger Robot for Simulating Fingers with Contracture and Spasticity (환자의 손가락 특성을 모사하는 로봇 개발)

  • Ha, D.K.;Song, M.;Park, H.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.233-238
    • /
    • 2014
  • In this paper, we developed a finger robot simulating spasticity and contracture which can be used as a testing bed for evaluating performance of hand rehabilitation devices while it can be also used to train clinicians for improving reliability of clinical assessment. The robot is designed for adult finger size and for independent control of Metacarpophalangeal Joint and Proximal Interphalangeal Joint. Algorithm for mimicking spasticity and contracture is implemented. By adjusting the parameters related to contracture and spasticity, the robot can mimic various patterns of responses observed in fingers with spasticity and contracture.

  • PDF

Foldable Electric Walking Design and Production for the Elderly (고령자를 위한 접이식 전동 보행보조기 디자인 및 제작)

  • Kim, B.M.;Lee, W.Y.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.299-303
    • /
    • 2014
  • Demand of moving auxiliary equipment has increased recently to an increase in the elderly population. pedestrian demand is either moving auxiliary equipment are also increasing. regional migration, such as pedestrian and the elderly and patients is a device to support the sharing received walking the weight of inconvenient people. In this paper, by mounting the electric function to the current manual walking, to prepare the electric walking to support the user's walking. the design applies a lightweight folding structure so that it can be moved to a ride at long distances, were fabricated.

  • PDF

Intelligent Retrieval System with Interactive Voice Support (대화형 음성 지원을 통한 지능형 검색 시스템)

  • Moon, K.J.;Yoo, Y.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • In this paper, we propose a intelligent retrieval system with interactive voice support. The developed system helps to find misrecognized words by using the relationship between lexical items in a sentence recognition and present the correct vocabulary. In this study, we implement a simulation system that can be proposed to determine the usefulness of the product search assistance system which offers applications. Experimental results were confirmed to correct the wrong speech recognition vocabulary in a simple user interface to help the product search.

  • PDF

A Study on the Smart Device of Accessibility for Persons with Disabilities (장애인의 스마트 기기 접근성 제고를 위한 개선방안 연구)

  • Hong, K.S.;Min, H.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • This study is to investigate the accessibility compliance status of smart devices for people with disabilities in the information age, smart and offer improvements. Vision of smart devices, operating systems (IOS, Android, Windows) based smart devices currently in use by most, hearing, investigation and provide handicapped accessibility status and improvement measures derived from a comparative analysis of the Disabled Accessibility Improvement of smart devices was presented.

  • PDF

A Research on the Wheelchair Carrier for Disabled Driver (장애인 휠체어 캐리어에 관한 연구)

  • Lee, S.C.;Park, S.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • In this paper, the feasibility of a wheelchair carrier for the disabled own driver is checked kinematically to fit one of current domestic vans by drawings, design. A van with 9 passengers is selected for the modification to attach the wheelchair carrier and test the operation in real situation. The trajectory and motion process are studied to protect from the interception with outside body of van, and the conceptual design is proceeded kinematically. For the detail design, the stress analysis and driving mechanism with power supply must be studied and selected basically.

  • PDF

Step Count Detection Algorithm using Acceleration Sensor (가속도 센서를 이용한 걸음수 검출 알고리즘)

  • Han, Y.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.245-250
    • /
    • 2015
  • Portable devices, such as smart phones and personal digital assistants (PDAs) play an important role in our everyday life. In this paper, we propose a step count algorithm based on SVM(signal vector magnitude) and a adaptive threshold processing to monitor the physical activity. The algorithm measures a user's step counts using the smart phone's inbuilt accelerometer and g sensor. Experiment results showed the proposed algorithm has good performance in accuracy and adaptability than the app on your smart phone.

  • PDF

The Radar Data Correction of the onto the Application of a Complementary Filter for the Handicapped Aids (상보필터 적용을 통한 장애인보조기구용 레이더 데이터 보정연구)

  • Park, Dong-Jin;Ryu, In-Hwan;Lee, Sang-Min;Kwon, Jang-Woo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • This paper presents an analysis of the short-range radar noise adjusting the angle of the radar reflector for the handicapped aids and suggests a complementary filter that combines a moving average filter with a heuristic algorithm to remove the radar noise. It also shows the effectiveness of the suggested filter by comparing the experiments results between the Kalman filter and the suggested filter.

Improvement of Speech/Music Classification Based on RNN in EVS Codec for Hearing Aids (EVS 코덱에서 보청기를 위한 RNN 기반의 음성/음악 분류 성능 향상)

  • Kang, Sang-Ick;Lee, Sang Min
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.143-146
    • /
    • 2017
  • In this paper, a novel approach is proposed to improve the performance of speech/music classification using the recurrent neural network (RNN) in the enhanced voice services (EVS) of 3GPP for hearing aids. Feature vectors applied to the RNN are selected from the relevant parameters of the EVS for efficient speech/music classification. The performance of the proposed algorithm is evaluated under various conditions and large speech/music data. The proposed algorithm yields better results compared with the conventional scheme implemented in the EVS.