• Title/Summary/Keyword: Assistive

Search Result 666, Processing Time 0.025 seconds

The Feasibility Study of Sit-to-stand and Stand-to-sit Assistive Chair for Elderly

  • Seonggwang Yu;Seungmuk Lee;Minsoo Kim;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.591-597
    • /
    • 2022
  • Objective: The sitting and standing are motions that correspond to the previous stage of rehabilitation to go to walking for daily life. The purpose of this study was to measure task times, path length of the center of pressure (COP) and activity on the vastus femoris muscle using surface electromyography (EMG) when standing up and sitting down. Design: One group cross-sectional design Methods: Fifteen elderly subjects (8 male, 7 female) participated. All subjects were tested three times according to four assist levels (non-assist, lower, middle, and maximal assist) using adjusts the length of spring at sit-to-stand and stand to sit on a chair. The task duration, and COP path length were recorded for the balance function on the Nintendo Wii fit board. The activity of the rectus femoris muscle was recorded on both legs using surface EMG. Results: The results showed that the task duration of the sit-to-stand and stand-to-sit were significantly increased compared to without assist (p<.05). The activation of the rectus femoris muscle more significantly decreased compared to without assistance at standing or sitting (p<.05). Conclusions: The assistive chair showed less quadriceps muscle activation during sitting and standing compared to without assistance. We suggest that our assist-standing chair can help with activities of daily living such as standing up and sitting down movements adjusting the spring length for control assist level by safely.

A Study on Synthesizing Training Data for One-stage Object Detector (단일 단계 검출 방법을 위한 이미지 합성기반 학습 데이터 증강에 관한 연구)

  • Lee, Seon-Gyeong;Jeong, Chi Yoon;Moon, KyeongDeok;Kim, Chae-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.05a
    • /
    • pp.446-450
    • /
    • 2020
  • 딥러닝 기반의 영상 분석 방법들은 많은 양의 학습 데이터가 필요하며, 학습 데이터 구축에는 많은 시간과 노력이 소요된다. 특히 객체 검출 분야의 경우 영상 내 객체의 위치, 크기, 범주 등의 정보가 모두 필요하여 학습 데이터 구축에 더 많은 어려움이 있으며, 이를 해결하기 위해 최근 이미지 합성기반 데이터 증강에 관한 연구가 활발히 진행되고 있다. 이미지 합성기반 데이터 증강 방법은 배경 영상에 객체를 합성할 때 객체와 배경 영상이 접한 영역에서 아티팩트(Artifact)가 발생하며, 이는 객체 검출 모델이 아티팩트를 객체의 특징으로 모델링하여 검출 성능이 저하되는 원인이 된다. 이러한 문제를 해결하기 위하여 본 논문에서는 양방향 필터 기반의 이미지 합성 방법을 제안하고, 단일 단계 검출의 대표적인 방법인 RetinaNet을 이용하여 이미지 합성기반 데이터 증강 방법의 성능을 분석하였다. 공개 데이터셋에 대한 실험 결과 본 논문에서 사용한 단일 검출 방법 및 데이터 증강 기법을 사용하면 더 적은 양의 증강 데이터로 기존 방법과 동일한 성능을 보여주는 것을 확인하였다.

Usability Test for Motion Tracking Gait Assistive Walker

  • Daon Hwang;Ki Hun Cho
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.4
    • /
    • pp.1-8
    • /
    • 2023
  • Background: This study evaluates the usability of the Motion-Tracking Gait Assistive Walker (MTGAW) designed for elderly individuals and those with disabilities, identifying areas for improvement through interviews with physical and occupational therapists. Design: A survey study involves the usability test for MTGAW. Methods: Usability evaluations were conducted with 37 physical therapists and occupational therapists. The process included explanation, product usage, satisfaction surveys, and interviews. A satisfaction survey covering 19 items across safety, maneuverability, usability, and management areas was administered. Individual interviews identified areas for improvement. Results: Overall, high satisfaction was reported across the four areas, but interviews highlighted the need for improvements, such as addressing discomfort due to slow speed and enhancing safety measures to prevent rear-end falls. Adjusting the walker's height and width to suit the user's physique was also suggested. Conclusion: MTGAW enhances walking support and hand movement freedom but needs refinement in speed control, fall prevention, and customization based on the user physique. Future efforts should focus on developing an improved MTGAW, considering recommendations from physical therapy experts, and conducting studies to analyze its clinical effectiveness for commercialization.

NREH: Upper Extremity Rehabilitation Robot for Various Exercises and Data Collection at Home (NREH: 다양한 운동과 데이터 수집이 가능한 가정용 상지재활로봇)

  • Jun-Yong Song;Seong-Hoon Lee;Won-Kyung Song
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.376-384
    • /
    • 2023
  • In this paper, we introduce an upper extremity rehabilitation robot, NREH (NRC End-effector based Rehabilitation arm at Home). Through NREH, stroke survivors could continuously exercise their upper extremities at home. NREH allows a user to hold the handle of the end-effector of the robot arm. NREH is a end-effector-based robot that moves the arm on a two-dimensional plane, but the tilt angle can be adjusted to mimic a movement similar to that in a three-dimensional space. Depending on the tilting angle, it is possible to perform customized exercises that can adjust the difficulty for each user. The user can sit down facing the robot and perform exercises such as arm reaching. When the user sits 90 degrees sideways, the user can also exercise their arms on a plane parallel to the sagittal plane. NREH was designed to be as simple as possible considering its use at home. By applying error augmentation, the exercise effect can be increased, and assistance force or resistance force can be applied as needed. Using an encoder on two actuators and a force/torque sensor on the end-effector, NREH can continuously collect and analyze the user's movement data.

Development and Evaluation of Safe Route Service of Electric Personal Assistive Mobility Devices for the Mobility Impaired People (교통약자를 위한 전동 이동 보조기기 안전 경로 서비스의 개발과 평가)

  • Je-Seung WOO;Sun-Gi HONG;Sang-Kyoung YOO;Hoe Kyoung KIM
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.3
    • /
    • pp.85-96
    • /
    • 2023
  • This study developed and evaluated a safe route guidance service for electric personal assistive mobility device used mainly by the mobility impaired people to improve their mobility. Thirteen underlying factors affecting the mobility of electric personal assistive mobility device have been derived through a survey with the mobility impaired people and employees in related organizations in Busan Metropolitan City. After assigning safety scores to individual factors and identifying the relevant factors along routes of interest with an object detection AI model, the safe route for electric personal assistive mobility device was provided through an optimal path-finding algorithm. As a result of comparing the general route of T-map and the recommended route of this study for the identical routes, the latter had relatively fewer obstacles and the gentler slope than the former, implicating that the recommended route is safer than the general one. As future works, it is necessary to enhance the function of a route guidance service based on the real-time location of users and to conduct spot investigations to evaluate and verify its social acceptability.

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

A Study on Standards for Hospital Bed and Operating Table (의료용 침대 및 수술대의 기준규격 연구)

  • Park, S.G.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.35-40
    • /
    • 2009
  • Electrically operated hospital bed and operating table are useful devices to care patients and to keep postures of them in medical treatment. However they have the risk of physical injury due to various functions and mechanisms consisting of them. In this paper we propose particular requirements for the safety and test methods of electrically operated hospital beds and operating table classified into medical devices. Each items are developed based on international standards. The results of this study can be used for developing internationally harmonized standards for the approval of Korea Food and Drug Administration (KFDA).

  • PDF

Estimate of walking state of the knee disarticulation prosthesis using position control algorithm of absolute encoder (절대위치 엔코더의 위치제어 알고리즘을 이용한 의지 장치의 보행 상태 추론)

  • Song, H.J.;Park, J.Y.;Shim, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2013
  • In this paper, we proposed how to estimate the walking state in the knee disarticulation prosthesis's knee angle control. In control of the knee disarticulation prosthesis, we can estimate walking state that measurement of knee angle using absolute encoder and measurement of load on the soles using strain gage. We suggested a method of estimating the current walking states which can be divided into four cases and showed the effectiveness of the method via a series of experiments.

  • PDF