• Title/Summary/Keyword: Artificial Heart Valve

Search Result 61, Processing Time 0.023 seconds

Long term Result of Valve Replacement in Children (소아 심장판막치환술의 장기성적)

  • 한재진
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.479-487
    • /
    • 1988
  • Valve replacements in 82 children, aging up to 15 years[mean 11.67 years] were done at Seoul National University Hospital during 13 years period from 1974 to 1986. The patients were composed of 5] males and 31 females and 50 patients had acquired heart disease and 32 patients congenital heart disease. 75 patients received single valve replacements, 6 patients double valve replacements, 1 patient triple valve replacement, and among all of them, 11 patients redo-replacements. The bioprosthetic valves have been applied to 58 patients and prosthetic valve to 24 patients and the latter was the main artificial valve since 1984. Among the 69 patients who had definite post-operative records, the overall mortality was 27.5%[20.3% was early mortality and 7.2% late mortality] and the overall mortality was lowered to 4.3% since 1984. There were early post-operative complication rate of 26.1% and late complication rate 34.8%, and among the latter, the valve failure rate was 11.4% patient-year, and the thrombo-embolism rate 1.76%/patient-year. 55 patients among the survivals after post-operative 1 month, were received follow-up with various anticoagulating medication for total 2046 patient-months[mini-mum 1 month to maximum 90 month, mean 37.2*25.44 months] and actuarial survival rate was 82*8% at 5 years and valve failure free and thrombo-embolic free survival rate were 61*8% and 90*3% respectively. And among them, valve failure free survival `rate of tissue valve were 91*6% at post-operative 2 years, 78*3% at 3 years, 59*9% at 4 years, 54*10% at 5 years, 53*15% at 6 years, so markedly decreased at 3-5 years post-operatively. These results suggest that cardiac valve replacement in children have been effective therapeutic method though various problems are still remained, and the choice of valve should be prosthetic valve mainly due to its durability at the present.

  • PDF

Finite Element Analysis of the Monoleaflet Polymer to Minimize Stress and Displacement (응력 및 변위를 최소화하기 위한 단엽식 고분자 판막의 유한 요소 해석)

  • 한근조;안성찬
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.85-92
    • /
    • 1996
  • A monoleaflet polymer artificial heart valve which showed the remarkable improvement in pressure drop compared with other types of artificial valve was designed to minimize the deflection in vertical direction and the displacement of the valve tip in horizontal direction obtained by using finite element method as the location of the supporting members of the valve frame changed stress distribution change was also studied on each model generated by changing the distance between the frame and supporting members. It was found that by using the valve tip horizontal displacement the minimum valve thickness could be obtained in order to prevent the gap between the valve tip and the frame wall.

  • PDF

Clinical Analysis of Repeated Heart Valve Replacement (심장판막치환술 후 재치환술에 관한 임상연구)

  • Kim, Hyuck;Nam, Seung-Hyuk;Kang, Jeong-Ho;Kim, Young-Hak;Lee, Chul-Burm;Chon, Soon-Ho;Shinn, Sung-Ho;Chung, Won-Sang
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.817-824
    • /
    • 2007
  • Background: There are two choices for heart valve replacement-the use of a tissue valve and the use of a mechanical valve. Using a tissue valve, additional surgery will be problematic due to valve degeneration. If the risk of additional surgery could be reduced, the tissue valve could be more widely used. Therefore, we analyzed the risk factors and mortality of patients undergoing repeated heart valve replacement and primary replacement. Material and Method: We analyzed 25 consecutive patients who underwent repeated heart valve replacement and 158 patients who underwent primary heart valve replacement among 239 patients that underwent heart vale replacement in out hospital from January 1995 to December 2004. Result: There were no differences in age, sex, and preoperative ejection fraction between the repeated valve replacement group of patients and the primary valve replacement group of patients. In the repeated valve replacement group, the previously used artificial valves were 3 mechanical valves and 23 tissue valves. One of these cases had simultaneous replacement of the tricuspid and aortic valve with tissue valves. The mean duration after a previous operation was 92 months for the use of a mechanical valve and 160 months for the use of a tissue valve. The mean cardiopulmonary bypass time and aortic cross clamp time were 152 minutes and 108 minutes, respectively, for the repeated valve replacement group of patients and 130 minutes and 89 minutes, respectively, for the primary valve replacement group of patients. These results were statistically significant. The use of an intra aortic balloon pump (IABP) was required for 2 cases (8%) in the repeated valve replacement group of patients and 6 cases (3.8%) in the primary valve replacement group of patients. An operative death occurred in one case (4%) in the repeated valve replacement group of patients and occurred in nine cases (5.1%) in the primary valve replacement group of patients. Among postoperative complications, the need for mechanical ventilation over 48 hours was different between the two groups. The mean follow up period after surgery was $6.5{\pm}3.2$ years. The 5-year survival of patients in the repeated valve replacement group was 74% and the 5-year survival of patients in the primary valve replacement group was 95%. Conclusion: The risk was slightly increased, but there was little difference in mortality between the repeated and primary heart valve replacement group of patients. Therefore, it is necessary to reconsider the issue of avoiding the use of a tissue valve due to the risk of additional surgery, and it is encouraged to use the tissue valve selectively, which has several advantages over the use of a mechanical valve. In the case of a repeated replacement, however, the mortality rate was high for a patient whose preoperative status was not poor. A proper as sessment of cardiac function and patient status is required after the primary valve replacement. Subsequently, a secondary replacement could then be considered.

Titanium Oxide Film : A New Biomaterial For Artificial Heart Valve Prepared by Ion Beam Enhanced Deposition

  • Liu, Xianghuai;Zhang, Feng;Zheng, Zhihong;Huang, Nan
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.1-15
    • /
    • 1997
  • Titanium oxide films were prepared by ion beam enhanced deposition where the films were synthesized by deposition titianium atoms and simultaneously bombarding with xenon ion beam at an energy of 40 keV in an $O_2$ environ,ent. Structure and composition of titanium oxide films were investigated by X-ray Doffractopm (XRD) Ritjerfprd Backscattering Spectroscopy (RBS) and X-ray Diffraction(XRD) Rutherford Backscattering Spectroscopy (RBS) and X-ray photoelectron spectroscopy (XPS) The results show that thestructure of the prepared films exhibit a rutile phase structure wit high(200) orientation and the O/Ti ratio of the titanium oxide films was about 2:1 XPS anlysis shows that $Ti^{2+},Ti^{3+}\;and\;Ti^{4+}$ chemical states exist on the titanium oxide films. the blood compatibility of the titanium oxide films was studied by measurements of blood clotting time and platelet adhesion. The results show that the anticoagulation property of titanium oxide films improved significantly and better than that of LTI-carbon which was widely used to fabricate artificial heart valve.

  • PDF

A Case Report of Ventricular Septal Defect with Bacterial Endocarditis and Pulmonic Valve Vegetation (심실중격결손증 환자에서 심내막염 및 폐동맥판막 증식물이 관찰되었던 1예 보고)

  • Park, Wha-Chong;Kim, Young-Jo;Sim, Bong-Sup;Kim, Chong-Suhl;Lee, Dong-Hyup;Lee, Cheol-Joo;Cho, Bum-Koo
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.241-247
    • /
    • 1985
  • Bacterial endocarditis has been well recognized as an important complication of congenital heart disease, such as ventricular septal defect, patent ductus arteriosus or pulmonary stenosis. The incidence of right sided bacterial endocarditis is lesser than left sided bacterial endocarditis. Also, pulmonic valve vegetation has been thought to be relatively uncommon. And pulmonary embolism is common in the patients with right sided bacterial endocarditis. So in a patient with fever and evidence of recurrent pulmonary infarction, changing heart murmurs and scattered pneumonic infiltrates, one should direct attention to the heart as a possible source of the infection. Echocardiography with M-mode, 2-D and Doppler mode represents the only noninvasive technic available for detecting vegetations in bacterial endocarditis. In fact, the technic is more sensitive in identifying these lesions than angiography. We experienced a case of ventricular septal defect with bacterial endocarditis, pulmonic valve vegetation and multiple pulmonary embolism diagnosed with Echocardiogram and lung scan, and confirmed by operation. Patch repair of ventricular septal defect, resection of pulmonic valve and vegetation and artificial valve formation with pericardium were done.

  • PDF

Aortic Stenosis: New Insights in Diagnosis, Treatment, and Prevention

  • Saki Ito;Jae K. Oh
    • Korean Circulation Journal
    • /
    • v.52 no.10
    • /
    • pp.721-736
    • /
    • 2022
  • Aortic stenosis (AS) is one of the most common valvular heart diseases and the number of patients with AS is expected to increase globally as the older population is growing fast. Since the majority of patients are elderly, AS is no longer a simple valvular heart disease of left ventricular outflow obstruction but is accompanied by other cardiac and comorbid conditions. Because of the significant variations of the disease, identifying patients at high risk and even earlier detection of patients with AS before developing symptomatic severe AS is becoming increasingly important. With the proven of efficacy and safety of transcatheter aortic valve replacement (TAVR) in the severe AS population, there is a growing interest in applying TAVR in those with less than severe AS. A medical therapy to reduce or prevent the progression in AS is actively investigated by several randomized control trials. In this review, we will summarize the most recent findings in AS and discuss potential future management strategies of patients with AS.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

The Clinical Results of Heart Valve Replacements (심장 판막 치환술의 임상 성적)

  • Park Sung Min;Son Hosung;Shin Jaesung;Sohn Young-sang;Sun Kyung;Choi Young Ho;Kim Kwan Taik;Lee In Sung;Kim Hackje;Kim Hyung Mook
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.204-213
    • /
    • 2005
  • In spite of the improvement in the quality of artificial heart valves and surgical techniques, the incidence of the complications following valve replacement is still high. We reviewed the clinical results of the valve replacements peformed in Korean University Anam Hospital during the last 26 years. Material and Method: The data of 571 patients who received valve replacement between December 1976 and December 2003 were reviewed. Result: There were 304 cases of MVR which was the most common procedure performed. There were 122 cases of AVR, and 111 cases of AVR with MVR. Among the 47 patients who received redo operation 38 cases were redo cases including 31 cases of MVR. $32.5\%$ of the patients who had tissue valve replacement had second valve replacement with 10.2 $\pm$ 3.9 years interval. $24.3\%$ (139/571) of the patients developed valve related complications and cerebral infarction was the highest in frequency. Atrial fibrillation was related with increased complication rates and the mechanical valve replaced group had higher hemorrhagic complication rate than tissue valve replaced group. The operative mortality was $3.68\%$ and the most common cause of the failure was low output syndrome. The operative mortality was higher in the patient group who had valve replacement before the year 1990. The patient group who had mechanical valve replacement had higher operative mortality rate th;3n the tissue valve group. The 5-year survival rate was $92.2\%$ and 10 year survival rate was $85.7\%$. Conclusion: The operative mortality of valve replacement has been improved. The mechnical valve replaced patients had higher hemorrhagic complication rate than the tissue valve replaced patients and more tissue valve replaced patients received redo valve replacement.

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

Clinical Analysis of St. Jude Medical Prosthesis (St. Jude Medical 기계판막의 임상적 연구)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF