• Title/Summary/Keyword: Artifacts

Search Result 1,682, Processing Time 0.026 seconds

Forming Shop Analysis with Adaptive Systems Approach (적응시스템 접근법을 이용한 조선소 가공공장 분석)

  • Dong-Hun Shin;Jong-Hun Woo;Jang-Hyun Lee;Jong-Gye Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.3
    • /
    • pp.75-80
    • /
    • 2002
  • In these days of severe struggle for existence, the world has changed a great deal to global and digital oriented period. The enterprises try to introduce new management and production system to adapt such a change. But, if the only new technologies are applied to an enterprise without definite analysis about manufacturing, failure fellows as a logical consequence. Hence, enterprise must analyze manufacturing system definitely and needs new methodologies to mitigate risk. This study suggests that the new approach, which is systems approach for process improvement, is organized to systems analysis, systems diagnosis, and systems verification. Systems analysis analyzes manufacturing systems with object-oriented methodology-UML(Unified Modeling language) from a point of product, process, and resource view. Systems diagnosis identifies the constraints to optimize the system through scientific management or TOC(Theory of constraints). Systems verification shows the solution with virtual manufacturing technique applied to the core problem which emerged from systems diagnosis. This research shows the artifacts to improve the productivity with the above methodology applied to forming shop. UML provides the definite tool for analysis and re-usability to adapt itself to environment easily. The logical tree of TOC represents logical tool to optimize the forming shop. Discrete event simulator-QUEST suggests the tool for making a decision to verify the optimized forming shop.

Comparison of Expression Profiling of Gastric Cancer by O1igonucleotide and cDNA Microarrays (O1igonucleotide Microarray와 cDNA Microarray를 이용한 위암조직의 대단위 유전자 발현 비교)

  • Jung, Kwang-Hwa;Kim, Jung-Kyu;Noh, Ji-Heon;Eun, Jung-Woo;Bae, Hyun-Jin;Lee, Sug-Hyung;Park, Won-Sang;Yoo, Nam-Jin;Lee, Jung-Young;Nam, Suk-Woo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.179-185
    • /
    • 2007
  • Gastric cancer is one of the most common malignancies in Korea, but the predominant molecular event underlying gastric carcinogenesis remain unknown. Recently, DNA microarray technology has enabled the comprehensive analysis of gene expression level, and as such has yielded great insight into the molecular nature of cancer, However, despite the powerful approach of this techniques, the technical artifacts and/or bias in applied array platform limited the liability of resultant tens of thousand data points from microarray experiments. Therefore, we applied two different any platforms, such as olignucleotide microarray and cDNA microarray, to identify gastric cancer related large-scale molecular signature of the same human specimens. When thirty sets of matched human gastric cancer and normal tissues subjected to oligonucleotide microarray, total 623 genes were resulted as differently expressed genes in gastric cancer compared to normal tissues, and 252 genes for cDNA microarray analysis. In addition, forty three outlier genes which reflect the characteristic expression signature of gastric cancer beyond array platform and analytical protocol was recapitulated from two different expression profile. In conclusion, we were able to identify robust large-scale molecular changes in gastric cancer by applying two different platform of DNA microarray, this may facilitate to understand molecular carcinogenesis of gastric cancer.

A Method for Selecting the Subwindows of Pseudomedian Filter for Digital Image Enlargement (디지털 영상 확대를 위한 Pseudomedian 필터의 부윈도우 설정 방법)

  • Kwak, No-Yoon;Kwon, Byong-Heon;Hwang, Byong-Won
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.9
    • /
    • pp.91-102
    • /
    • 1999
  • It is known that the digital image enlargement technique which only uses spatially neighbored pixels information in a still image can increase the size of the image but the practical enhancement of resolution is small because the frequency bandwidth of the image is basically limited. To solve this problem, this paper proposes the digital image enlargement technique that improves the reconstruction of the edge components by selectively transposing the direction of the subwindows of pseudomedian filter according to the distribution of neighbored pixels to the interpolation point. The pseudomedian filter has the better performance in aspect of the reconstruction of edge information when the pixel values masked by two subwindows parallel to the interpolation point are very similar and the pixel values masked by another subwindow that is orthogonal to the above two subwindows are similar to each other. In this paper, the computer simulation for digital image enlargement was performed with consideration of these characteristics when selecting the subwindows of pseudomedina filter. Based on this simulation result, the performance of the proposed method was analysed and its effectiveness was assessed. According to the proposed method, visual artifacts that result from using the limited samples can be effectively suppressed, and most characteristics and shapes of the original image can be preserved as well.

  • PDF

Cancellation of Motion Artifact in MRI (MRI에 있어서 체동 아티팩트의 제거)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.3
    • /
    • pp.70-78
    • /
    • 2000
  • In this study, a new method for canceling MRI artifacts through the motion translation of image plane is presented Breathing often makes problems in a clinical diagnosis. Assuming that the head moves up and down due to breathing, rigid translational motions in only y(phase encoding axis) direction are treated Unlike the conventional Iterative phase retrieval algorithm, this method is based on the MRI imaging process and analyzing of Image property A new constraint condition with which the motion component and the true image component in the MRI signal can be separated by a simple algebraic operation is extracted After the x(read out) directional Fourier transformation of MRI signal is done, the y(phase encoding) directional spectrum phasing value is Just an algebraic sum of the Image component and the motion component Meanwhile, as It is known that the density of subcutaneous fat area is almost uniform in the head tomographs, the density distribution along a y directional line on this fat area is regarded as symmetric shape If the density function is symmetric, then the phase of spectrum changes linearly with the position Hence, the departure component from the linear function can be separated as the motion component Based on this constrant condition, the new method of artifact cancellation is presented Finally, the effectiveness of this algorithm IS shown by using a phantom with simulated motions.

  • PDF

Design of a Pipelined Deblocking Filter with efficient memory management for high performance H.264 decoders (효율적인 메모리 관리 구조를 갖는 H.264용 고성능 디블록킹 필터 설계)

  • Yu, Yong-Hoon;Lee, Chan-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.64-70
    • /
    • 2008
  • The H.264 standard is widely used due to the high compression rate and quality. The deblocking filter of the H.264 standard improves the quality of images by eliminating blocking artifacts of pictures, and it requires a lot of computation. We propose a new hardware architecture for the deblocking filter with pipelined architecture, 1-D filters which support both horizontal and vertical filtering and efficient memory management. Four memory blocks are configured for the efficient storage and access of the current macroblock and adjacent referenced sub-macroblocks, and the pixel data from the motion compensation unit can be transferred without waiting during the computation cycles of the deblocking filter. The number of computation cycles and the hardware area are reduced using the proposed architecture, and the performance of the H.264 decoder is improved. We design the deblocking filter using Verilog-HDL and implement using an FPGA. The designed deblocking filter can be used for decoding HD quality images at 77 MHz.

Reevaluation of the Songguk-ri site (송국리유적 재고)

  • Son, Jun-Ho
    • KOMUNHWA
    • /
    • no.70
    • /
    • pp.35-62
    • /
    • 2007
  • Songguk-ri site gained academic recognition by the excavation of stone coffin tomb with a bronze dagger in 1974. And it is confirmed that this site is epoch-making in Korean bronze age through the following excavation started in 1975. But the excavation reports published until now do not have even overall view of this site, thus it is difficult to get the whole picture of this site. Thus, in this paper the author reexamined all reports on this site and by making the map of overall view and distribution of archaeological features as a basic research. Moreover, I analyzed also artifacts from this site, and compared with the recent papers written by other researchers about the chronology and character. Songguk-ri site has livelihood domain which consists of dwelling pits, attached features, storage pits, pot-firing features, wood fence, abatises, buildings above ground, as well as cemetery which consists of stone-coffins, jar-coffins, pit tombs. Trace of making large terrace was also excavated. These features seem to belong to the same archaeological stage, dated about B.C.850-550, according to C14 dating. On the other hand, the intensification of wet-rice cultivation made this group more productive. Based on this financial strength, some influential group emerged they constructed defensive settlement to protect their products safely. Besides it seems that there were frequent occurrence of conflicts. However, we can know that they kept their stable life, through the expansion of living space. Consequently, Songguk-ri site played a role of the summit among some settlement in this area.

  • PDF

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF