• 제목/요약/키워드: Artifact

검색결과 1,020건 처리시간 0.036초

저 전송률 비디오 부호화 환경에서 잔상 현상의 제거 기술에 관한 연구 (Trailing Artifact Avoidance for Low Bit-Rate Video Coders)

  • 조용호;이신욱;장의선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.327-330
    • /
    • 2005
  • In this paper, we proposed that technique for reducing trailing artifact in MPEG-4 video. low bit-rate video is occured trailng artifact which remain part of moving object. Because MEMC doesn't work well in the degraded video. The proposed trailing artifact reduction approach has at its core three main steps. First step is to detect trailing artifact. Second step is applied intra block coding to remove trailing artifact. Finally, bit-rate control algorithm is used. Experimental result using an MPEG-4 based encoder indicate that the proposed method has overhead(bits) of about 2 percent and proposed method effective reduce or eliminate trailing artifact

  • PDF

Machine Tools 공간오차 분석을 위한 Bal1-bar Artifact 연구 (A Study on the Ball-Bar Artifact for the Volumetric Error Calibration of Machine Tools)

  • 이응석;구상서;박달근
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.986-991
    • /
    • 2004
  • For volumetric error measurement and calibration for machine tools, manufacturing machine or coordinate measuring machine (CMM), are studied using a Ball-bar artifact. A design of the Ball-bar is suggested manufactured by Invar, which is a low thermal expansion material, and precision steel balls. The uncertainty for the artifact method is discussed. A method of the Ball-bar artifact for obtaining 3-D position errors in CMM is proposed. The method of error vector measurement is shown using the Ball-bar artifact. Finally, the volumetric error is calculated from the error vectors and it can be used for Pitch error compensation in conventional NC machine and 3-D position Error map for calibration of NC machine tools.

Using Bayesian Approaches to Reduce Truncation Artifact in Magnetic Resonance Imaging

  • 이수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.585-593
    • /
    • 1998
  • 퓨리에 자기공명영상 기법의 경우 촬영시간 단축 및 적절한 신호대잡음비 유지를 위해 phase-encoded 신호의 개수를 감소시키는 경우가 종종 있다. 그러나, 이는 재구성된 영상에 번짐과 물결무늬 형태의 truncation artifact를 초래한다. 본 논문에서는 이러한 truncation artifact를 감소시키기 위해 Bayesian 방법에 근거한 새로운 정칙화기법을 제안한다. Truncation artifact는 phase 방향으로만 형성되므로 종전의 상호 대칭형태의 주변화소를 고려한 piecewise smoothness 사전정보를 사용할 경우 read 방향으로의 미세한 영상정보가 유실되기 쉽다. 따라서, 본 연구에서는 종전의 단순대칭형 보다 개선된 형태로서 자기공명영상의 공간정보를 포착할 수 있는 정교한 사전정보의 형태를 제안한다. 본 연구진의 실험결과 새롭게 제안된 방법으로 적용할 경우 truncation artifact가 감소될 뿐 아니라 종전의 미세정보유실 현상이 감소됨으로써 tissue regularity와 경계가 한층 더 향상됨을 확인할 수 있었다.

  • PDF

두경부 PET/CT검사 시 인공음영 감소에 관한 연구 (환자 피폭선량 경감) (The Study of Decrease Artifact when Scanning Head and Neck PET/CT(Decrease Radiation Dose of Patient))

  • 김기진;김가중;유세종;김정호
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.153-158
    • /
    • 2016
  • Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.

MR Artifacts

  • 문치웅
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.73-83
    • /
    • 2001
  • 영상의 좋고 나쁨을 나타낼 때는 대조도, 해상도, 잡음 그리고 Artifact 등을 정량적으로 측정하거나 기준이 되는 영상과 정성적으로 비교하게 된다. 이 중에서 Artifact는 영상의 해부학적 진단에 오류를 범하게 하여 엉뚱한 병리학적 해석을 내리게 하거나 해석이 불가능하게 하기도 하므로 적절한 규명을 하여 그 원인을 제거하는 등, 응당한 조치를 취해 최상의 화질을 유지하기 위한 노력을 기울여야한다. MR 영상에서 Artifact는 기하학적 늘림(stretch), 주름(wrinkle), 왜곡(distortion), 허상(ghost), 줄(line), 눈잡음(snow noise), 신호의 증감 등과 같은 다양한 현상으로 나타나며 이들은 영상을 해석할 때 오류를 범하는 원인이 된다. Artifact의 발생원인으로는 MR 장치의 기능장애, 부적절한 영상기법의 구사, 또는 MR 영상의 고유한 성질에 기인하기도 한다. MR Artifacts의 근본적인 이해를 위해서는 MRI의 물리적 원리와 장비에 관한 이해가 필요하다. 이렇게 MR Artifact는 여러 가지 인자들이 복합적인 관계를 가지고 나타나기 때문에 분류하기가 쉽지 않지만 전형적인 양상과 원인 그리고 그에 대한 여러 가지 대책을 살펴보고자 한다.

  • PDF

뇌파진단 시스템에서 artifact 제거를 위한 신경망 최적화 (Optimizing neural network for artifact reduction in electroencephalogram diagnostic system)

  • 전수열;조상흠;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1981-1982
    • /
    • 2008
  • 뇌파신호 측정 시에는 환자의 움직임 등으로 artifact가 발생하게 된다. 따라서 정확한 진단에는 이와 같은 artifact를 제거하는 것이 중요하다. 본 논문에서는 뇌파신호에서 발생할 수 있는 artifact 중 EOG(Electrooculogram: 안전위도)를 검출하고 제거하기 위한 방법으로 EOG 필터링(EOG filtering)을 제안하며, 나머지 근전도를 제거하기 위해 신경망(neural network)를 사용한다. 이때 입력신호의 특징이 신경망에 보다 잘 적용될 수 있도록 비선형 양자화기를 적응적으로 동작시키는 방법을 제안한다. 제안하는 방법을 통해 뇌파신호의 artifact를 효과적으로 제거할 수 있다.

  • PDF

독립 요소 분석을 통한 Photoplethysmography에서의 동잡음 제거 (The Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis)

  • 김경하;유선국;김병수;김남현
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권10호
    • /
    • pp.598-605
    • /
    • 2003
  • In this paper, we propose the method that separates PPG signal and motion artifact signal from two input signals using new independent component analysis algorithm in time domain. In order to eliminate the large level artifact efficiently, block interleaving. lowpass time filtering and innovation processing technique were applied in ICA preprocessing, and FastICA algorithm were applicable. Experiments are made with the numerical simulation and the real PPG signal including four kinds of motion artifact pattern. Our results show that ICA can effectively detect, separate and remove motion artifact in input signals. Then from the separated signals we restore the original PPG signal and propose a new method which computes SpO$_2$ using ICA mixing matrix.

단양 현곡리 출토 고려시대 섬유류 및 지류 유물에 관한 연구 (Analyses on Artifacts of Koryo Kynasty Excavated from Hyungok-ni Danyang)

  • 안춘수;박희현
    • 한국의류학회지
    • /
    • 제23권8호
    • /
    • pp.1161-1169
    • /
    • 1999
  • This research was aimed to identify the artifact type and their characteristics of the textile related materials excavated from Koryo Dynasty tombs of Hyungok-ni Danyang. Microscopy solubility test energy dispersive X-ray spectroscopy(EDS) and fourier transform infrared spectroscopy (FT-IR) fabric density test were used for the identification and when necessary standard samples were made in order to compare its characteristics with hose of the original artifact, the result indicated that the artifacts included both textile and paper. Artifacts from Burial 14 were comprised of textile fragments FT-IR and the solubility test conducted on the artifact indicated that the textiles were made with ramie woven with plain weave technique in a fairly loose fabric density. Rest of the artifacts were all comprised of paper.

  • PDF

완전 데이터 적응형 MLS 근사 알고리즘을 이용한 Interleaved MRI의 움직임 보정 알고리즘 (Motion Artifact Reduction Algorithm for Interleaved MRI using Fully Data Adaptive Moving Least Squares Approximation Algorithm)

  • 남혜원
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.28-34
    • /
    • 2020
  • In this paper, we introduce motion artifact reduction algorithm for interleaved MRI using an advanced 3D approximation algorithm. The motion artifact framework of this paper is data corrected by post-processing with a new 3-D approximation algorithm which uses data structure for each voxel. In this study, we simulate and evaluate our algorithm using Shepp-Logan phantom and T1-MRI template for both scattered dataset and uniform dataset. We generated motion artifact using random generated motion parameters for the interleaved MRI. In simulation, we use image coregistration by SPM12 (https://www.fil.ion.ucl.ac.uk/spm/) to estimate the motion parameters. The motion artifact correction is done with using full dataset with estimated motion parameters, as well as use only one half of the full data which is the case when the half volume is corrupted by severe movement. We evaluate using numerical metrics and visualize error images.

두 경부 종양의 C-T 영상을 이용한 방사선 치료계획시 Artifact가 선량 계산에 미치는 영향

  • 김경태;주상규
    • 대한방사선치료학회지
    • /
    • 제13권1호
    • /
    • pp.109-112
    • /
    • 2001
  • 1. 목적 : head and neck cancer 환자의, C-T 영상을 이용한 방사선치료계획시 치과 보철물에 의해 발생하는 artifact가 선량 계산에 미치는 영향을 분석하고자 한다. 2. 재료 및 방법:두 경부와 유사한 크기의 Polystyrenes Phantom ($20{\times}20{\times}25cm^3$) 을 제작하고, 팬톰내에 금으로 인공보철물을 제작하여 보철물 부착 전.후를 C-T Scan (High Speed Advantage, GE, US) 하였다. artifact에 의한 영향을 쉽게 분석하기위해 팬톰내에 다른 구조물은 만들지 않았으며 두가지 방법으로 얻어진 영상을 이용하여 조사면의 크기와 조사 방향을 변화 시켜 가며 1문 조사(SSD 100 cm)에 의한 치료 계획(3D RTP system, Prowess, US)을 수립하여 기준점(5,10 cm depth)에서의 선량 변화를 비교 분석하였다. 아울러 3회 반복 scan하여 artifact에 발생 유형과 CTNo을 이용한 density을 분석하였다. 3. 결과: C-T Scan으로 얻어진 image 상에 나타난 Artifact는 CT no $-1000{\sim}+2775$(기준 $-1000{\sim}+3700$)까지의 다양한 값을 가지며 보철물을 기준으로 방사형태로 분포하였다. artifact가 선량 계산에 미치는 영향을 분석한 결과 보철물 사용시 5cm깊이의 기준점에서 절대선량은 평균 $+1.5{\pm}2.8\%$, 10 cm 깊이에서는 $+1.8{\pm}3.5\%$의 오차를 보였다. 조사방향에 의한 오차는 artifact에 대해 측면 조사한(gantry $270^{\circ}$)경우에서 높게 관찰되었다. 4. 결론: 두 경부 종양의 방사선 치료시 치과 보철물에 의한 artifact는 흔히 관찰가능하며 본 실험을 통해 다양한 형태와 다양한 density을 가짐을 알수있었다. 영상에 나타난 정도에 비해 선량계산에 미치는 평균 오차는 낮게 평가되었지만 조사 방향과 보철물의 위치에 따라 변동이 크게 나타날 수 있어 치료 계획시 가능한 artifact의 영향을 적게 받는 빔의 선택이 정확한 선량 계산에 도움을 줄 것으로 사료된다.

  • PDF