• Title/Summary/Keyword: Arthroscopic anterior cruciate ligament reconstruction

Search Result 65, Processing Time 0.022 seconds

Arthroscopic Anterior Cruciate Ligament Reconstruction using Fresh Frozen Achilles Allograft - Clinical results, 2nd look Arthroscopic and Histologic findings - (신선 동결 아킬레스 동종건을 이용한 전방 십자 인대 재건술 - 임상적 결과, 2차 관절경 및 조직학적 소견 -)

  • Chun Churl Hong;Ha Dae Ho;Choi Min Kyu;You Son Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Purpose : We observed usability of allograft by evaluating the clinical results, second look arthroscopic and histologic findings at last follow up after anterior cruciate ligament(ACL) reconstruction using by fresh frozen Achilles allograft. Materials and Methods : We analyzed in 58 patients(59 cases) by subjective and objective parameters, Telos stress arthrometer and Modified Feagin Scoring System. The average age and follow up period was 25 years(ranging from 18 to 49 years), and 15 months(ranging from 12 to 19 months). Among them we studied second look arthroscopic and histologic findings in 16 patients. Results : The mean Lysholm Score wits improved from 60 to 88.2 as well the anterior translation was improved from 7.1 min to 2.3mm at last follow up. The second look arthroscopic findings were close to normal in ligament thickness, tension and showed revasculization at the holly attachment site. Light microscope(LM) findings showed dense cellularity like a normal ligament. In electron microscope(EM) collagen fibrils showed parallel arrangement longitudinally and unimodal pattern diameter close to normal tissue in the transverse section. Conclusion : We think that the fresh frozen Achilles allograft is a good substitution of autograft in cruciate ligament reconstruction.

  • PDF

Arthroscopic Revision ACL Reconstruction (전방십자인대 재재건술)

  • Ahn Jin-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.20-27
    • /
    • 2003
  • It is reported that approximately 100,000 anteior cruciate ligament (ACL) reconstructions are performed in the United States each year. Recurrent instability because of graft failure is estimated to occur in from 0.7$\%$ to 8$\%$ of reconstruction. Recently revision ACL reconstruction is likely to become more common as the number of primary reconstructions continues to increase. Arthroscopic revision ACL surgery with adequate graft for failed ACL reconstruction was successful in objectively and subjectively improving stability. However, considering the most common causes of failure after ACL reconstruction were errors in surgical technique, it is important that the primary ACL reconstruction should be performed with correct surgical technique. Therefore author reviewed the causes of failure of reconstruction to prevent the failure of reconstruction and described the surgical technique of revision ACL reconstruction.

  • PDF

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

Pretibial Cyst After Arthroscopic Revisional Anterior Cruiate Ligament Reconstruction - A Case Report - (전방 십자 인대 재재건술 후 발생한 전경골 낭종 - 증례 보고 -)

  • Kim, Ha-Kyung;Yoon, Jung-Ro;Kim, Taik-Sun;Yeo, Eui-Dong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.225-228
    • /
    • 2008
  • Pretibial cyst formation is a rare occurrence after anterior cruciate ligament (ACL) reconstruction. We report this complication after ACL revision surgery using tibialis anterior allograft. This complication seems to be the consequence of a direct communication between the joint and the cyst through the tibial tunnel. In the present study, the authors report that there is a pretibial cyst formation after a revisional ACL reconstruction.

  • PDF

Integration of Four-Strand Hamstring Tendon Graft with Bone in Reconstruction of the Anterior Cruciate Ligament -Report of one case- (슬괵건을 이용한 전방십자인대 재건술시 이식건과 골 사이의 골통합에 대한 조직학적 변화 - 1례 보고 -)

  • Jung, Young-Bok;Jang, Eui-Chan;Yum, Jae-Kwang;Park, Geun-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.40-43
    • /
    • 1999
  • Arthroscopic anterior cruciate ligament(ACL) reconstruction using four-strand hamstring tendon with looping around transfixing screw in femoral tunnel requires osteointegration between the grafted tendon and bone for stability of the knee. Authors have experienced a histologic finding of osteointegration between the grafted autogenous hamstring tendon and bone in femoral tunnel after arthroscopic ACL reconstruction. A patient received arthroscopic ACL reconstruction with autogenous four strand hamstring tendon for the ACL injury. Traumatic re-rupture of mid-substance of ACL graft was developed at thirteenth week after operation. During the procedures of arthroscopic revision at fifteenth week after initial ACL reconstruction, biopsy was performed at the site of interface between grafted tendon and bone in femoral tunnel. Integration between the grafted tendon and bone was evident by demonstrating the continuity of collagen fiber between bond and tendon. This histologic finding and the low incidence of early graft failure suggest that free tendon autograft attached to bone by looping around a transfixing screw in femoral tunnel undergoes adequate osteointegration between 12 and 15 weeks after surgery and authors thought that insertion of bone chip into the femoral tunnel would accelerate osteointegration procedure.

  • PDF

Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 슬개건을 이용한 전방 십자 인대 재건술의 수술 후 합병증)

  • Zhu, Fang Zhen;Yoo, Moon-Jib;Kim, Myung-Ho;Park, Hee-Gon;Bahng, Seung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: Evaluation and analysis of the incidence of postoperative complications after arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. Materials and Methods: We reviewed 172 cases of arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft in anterior cruciate ligament tear without meniscal injury. We performed Lysholm knee score and KT-2000 testing, simple radiograph, physical examination as evaluation factor. Also, around knee pain, swelling, limitation of motion, patellofemoral crepitation, paresthesia and pain on kneeling were evaluated. Results: The average follow up period was 49.8 months. In 172 patients, 148 males and 26 femlaes were evaluated. The average age was 34.4 years. The Lysholm knee score improved from 51.9 points preoperatively to 90.8 points at final follow up. Clinical outcome was excellent in 83%, good in 11%, fair in 4% and poor in 2%. There were many cases of complications, 24 cases (14%) of around knee pain, 12 cases (7%) of swelling, 45 cases (26.2%) of patellofemoral crepitation, 52 cases (30%) of donor site paresthesia, 65 cases (38%) of pain on kneeling, 10 cases (5.8%) of limitation of motion at extension, 13 cases (8%) of limitation of motion at flexion and 2cases (1.2%) of patellar fracture. Conclusion: Although arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone had good clinical results, many complications were noted. Some factors in surgical technique were suspected to be related to the complications and long term follow up will be necessary to further evaluated.

  • PDF

Revision Anterior Cruciate Ligamnet Reconstruction (전방 십자 인대 재재건술)

  • Ahn, Jin-Hwan;Lee, Sang-Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.115-122
    • /
    • 2005
  • With the increasing number of primary ACL reconstructions, revision surgery has become more frequent. Despite arthroscopic technique and treatment advancements, the current methods of reconstruction are far from perfect that a significant number of patients have an unsatisfactory. This article discusses the multiple mechanisms of failure of primary intra-articular ACL reconstruction and provides the orthopaedic surgeon with a systematic approach to the evaluation and treatment of failed ACL reconstructions.

  • PDF

Pretibial Cyst after Anterior Cruciate Ligament Reconstruction Using bio-absorbable interference screw fixation - A Case Report - (생체분해성간섭나사를 이용한 전방십자인대 재건술 후 발생한 경골 근위부 낭종-증례 보고-)

  • Chun, Keun Churl;Kim, Jung Woo;Kim, Tae Kuyn;Chun, Churl Hong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Pretibial cyst formation is a rare complication after anterior cruciate ligament (ACL) reconstruction and there are only few cases reported. Pretibial cyst can be caused by variable reasons. Foreign body reaction due to breakdown of bio-absorbable screw for fixation, graft necrosis at tibial site, joint fluid leakage to tunnel and incomplete incorporation of graft to bony tunnel. The authors experienced one case of massive pretibial cyst after arthroscopic ACL reconstruction using bio-absorbable interference screw in 38-year-old male patient. Thus, authors report this rare case with literature view.

  • PDF

Intraarticular Migration of Intrafix Sheath during Arthroscopic ACL Reconstruction (관절경적 전방 십자 인대 재건술 중 발생한 IntraFix Sheath의 관절 내로의 이동)

  • Cho, Suk-Hoon;Seo, Young-Jin;Kim, Yong-Kuk;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.120-123
    • /
    • 2010
  • An inappropriate insertion of a interference device to fix the graft in the tibial tuunel can cause potential complications. We describe a case of 27-year-old man who underwent anterior cruciate ligament reconstruction using IntraFix device(DePuy Mitek, Raynham, MA). In this report we present a case of migration of IntraFix sheath by inappropriate insertion of IntraFix screw along with a review of the current literature.

  • PDF

Arthroscopic Evaluation for Endoscopic ACL Reconstruction Using a Multi-stranded Hamstring Tendon Graft and EndoButton (슬괵 건을 이용한 전방십자인대 재건술후 2차 관절경적 평가)

  • Lee, Kwang-Won;Lee, Byeong-Ki;Ryu, Chang-Soo;Keum, Teok-Seop;Choy, Won-Sik;Kim, Joon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.124-128
    • /
    • 1998
  • From Feb. 1996 to Feb. 1997. among sixty-four patients of anterior cruciate ligament(ACL) reconstruction using multi-stranded hamstring tendon and EndoButton fixation, twenty-five patients of volunteer, 15 men and 10 women, from 16 to 50 years of age(mean 27.6 years) underwent arthroscopic evaluation. Arthroscopic evaluation was routinely performed one year after surgery along with an examination of stability. The purpose of this study was to arthroscopically evaluate the morphological changes that occurred in hamstring tendon autograft one year after ACL reconstruction. Both of the tendon graft and the adjacent fibrous tissues were observed for gross appearance and physical properties with probing and response to passive anterior translation. Biopsy samples were taken from the surrounding fibrous tissue and the tendon graft. Grossly, we found a well-defined ligamentous structure with good tension tested with a probe. A common finding was that the reconstructed ligaments were embedded in a layer of the synovium, and blood vessels could be seen on the anterior surface of the ligament. The biopsy tissue was placed in formalin solution and subjected to histological preparation by hematoxylin and eosin staining method. The hamstring tendon graft appeared histologically normal under light microscopic finding. There were a few vessels located between existing collagen bundles, and the vessels had an orderly pattern. The surrounding fibrous tissue envelope was covered with synovium. We pleased with preliminary findings in our evaluation.

  • PDF