• 제목/요약/키워드: Arterial and Venous blood pressure

검색결과 57건 처리시간 0.026초

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발 (Development of pulse diagnosis possible simulator using the stepper motor pumps)

  • 류근택;우성희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.915-918
    • /
    • 2016
  • 의료산업의 급속한 변화와 의료 및 간호 인력의 증가로 인하여 가상 시험 장치에 대한 개발이 요구되고 있으며 심장 모델링할 수 있는 시뮬레이터와 혈관, 혈류에 대한 실습장비에 대한 개발의 중요성이 증가하고 있다. 따라서 본 연구에서는 스텝 모터를 이용하여 심장 펌프를 제작하여 동맥과 정맥 혈압, 혈류 시뮬레이션을 위한 장비를 개발하고 그 기능을 평가하고자 한다. 제안 시스템은 심장 시뮬레이션을 위한 펌프와 동맥, 정맥 혈관의 저항을 모사하기 위한 밸브장치 그리고 정맥계의 특성을 나타내는 저감장치로 구성한다. 심장 시뮬레이터는 롱거펌프(BOXER)를 사용하였으며 동맥과 정맥혈관은 실리콘 튜브를 사용하고 저감장치를 설계 및 제작하였다. 그리고 동맥혈압 측정을 위하여 압력센서를 사용하였다. 또한 제안 시스템의 평가를 위하여 심장 박동수는 분당 60회로 혈압의 범위는 50 ~ 100mmHg로 선정하여 측정 혈압과 사람의 혈압을 비교 평가하였다.

  • PDF

자라에서 본 관류액(灌流液) pH와 심장박출량(心臟搏出量) (Cardiac Performance of Turtle Heart in Various pH of Perfusate)

  • 양일석
    • The Korean Journal of Physiology
    • /
    • 제9권1호
    • /
    • pp.69-76
    • /
    • 1975
  • Cardiac performances were analyzed in intact turtle heart(Amyda japonica), perfusing with turtle Ringer-Locke's solution containing various hydrogen ion concentration, at several levels of arterial and venous pressure. 1. Ventricular work increased when venous pressure, or venous filling pressure increased, and also increased when arterial pressure increased. 2. The higher the arterial pressure, the lower the cardiac to output, for arterial pressure is the resistance to the ventricular blood flow. On the other hand, in specific arterial pressure, cardiac output was proportional to the venous filling pressure. 3. Heart rates did not change significantly during the perfusion with Ringel· solution of various pH. 4. In the heart Perfused with Ringer solution of various pH, ventricular work was the highest at PH 7.6 (at 6 $cmH_2O$ arterial pressure and 8 $cmH_2O$ venous pressure, the ventricular work was 63.09m$\cdot$cm). However, within the range of pH $7.1{\sim}7.6$, there were no significant changes in cardiac output and ventricular work. Below the level of pH 7.0, ventricular work decreased to less than 56% of maximium value (at $6cmH_2O$ arterial pressure and $8cmH_2O$ venous Pressure, ventricular work was 36.0$gm{\cdot}$ at pH 7.0). At pH 7.7 ventricular work decreased to less than 48% of maximum value (ventricular work: 30.0 $gm{\cdot}$). The nature of the cardiac performance at the various arterial and venous pressures was similar to that of normal heart. 5. Turtle heart seemed to be relatively insensitive to acid-base disturbances. The mechanism of negative inotropic effect of hydrogen ion was discussed.

  • PDF

체위변화에 수반되는 심맥관계반응에 관한연구 (A Study of Circulatory Responses to Postural Changes)

  • 서석완;채의업
    • The Korean Journal of Physiology
    • /
    • 제5권2호
    • /
    • pp.71-78
    • /
    • 1971
  • Anesthetized dogs were tilted from horizontal to the upright and head down position. Tilting to the upright position was followed by an increase in heart rate. In the head down position a decreased heart rate was obtained. The arterial blood pressure was decreased in the upright position and was decreased markedly in the head down position. The central venous pressure was decreased in the upright position and was markedly decreased down to the negative pressure in the head down position. The respiratory rate was slightly increased in the upright position comparing to that in the horizontal position. No remarkable changes were noted in the head down position. From the above results the following factors were discussed The decreased arterial blood pressure during the upright position was supposed to be the secondary effect from the diminished venous return that was suggested by the decreased central venous pressure. The decreased arterial blood pressure in the head down position was also supposed as the above reason as the diminished central venous pressure during the tilt. In addition the cardioinhibitory effects originated from the baroreceptors might have been operated during head down tilting. In the heart rate there was slight tachycardia in the upright position this was assumed as the abolished cardioinhibitory impulses from the baroreceptor in the upright position. On the contrary, despite of the decrease of arterial blood pressure in the head down position as well as in the upright, the bradycardia have been appeared. This was suggestive of cardioinhibitory impulses from the baroreceptors which was stretched during head down tilting. From the above findings there is a possibility of continous cardioinhibitory responses during head down tilting for this kind of the short period of 10 minutes which was chosed in this study.

  • PDF

폐내압증가시(肺內壓增加時)의 동맥혈압(動脈血壓) 및 심박변동(心搏變動)에 관(關)하여 (Responses of Systemic Arterial Blood Pressure and Heart Rates to Graded Increase of Positive Lung Inflation)

  • 김규수;오상유;최병옥;이중길
    • The Korean Journal of Physiology
    • /
    • 제3권2호
    • /
    • pp.25-31
    • /
    • 1969
  • Effects of graded increase of positive lung inflation upon heart rates and arterial blood pressure were observed in the anesthetized dogs to analyze the mechanical and neural regulatory factor in response to the positive inflation of the lung. The results obtained were summarized as followings: 1) When the low grade of positive lung inflation was employed under the mild to moderate anesthesia, central venous pressure was linearly increased while heart rate was decreased. After bilateral vagotomy, central venous pressure was obviously increased while heart rate was constant. 2) When the high degree of positive lung inflation was employed, changes of central venous pressure and heart rate were not significant. 3) The low grade of intrapulmonary pressure increase caused reflex tachycardia in phase 2 and overshooting in phase 4 in response to the systemic arterial blood pressure change. 4) On the other hand, the high degree of intrapulmonary pressure increase caused paradoxical bradycardia in phase 2 and lack of overshooting in phase 4 in response to the systemic arterial blood pressure change. 5) It may be noted that the experimental model employed in the present study is a useful tool to evaluate and analyze the neural and mechanical regulatory factor in response to the graded increase of the positive lung inflation.

  • PDF

동맥혈 및 뇨 $P_CO_2}, P{O_2}$ 의 산-염기 균형 및 뇨량과의 관계 (Relationships between arterial and urinary $P_CO_2}, P{O_2}$ and acid-base balances)

  • 김용진;이영균
    • Journal of Chest Surgery
    • /
    • 제16권2호
    • /
    • pp.213-220
    • /
    • 1983
  • Pulmonary function is the determinant of blood gas tension. However, Acid-Base disturbances can also alter partial pressures of oxygen and carbon dioxide in arterial blood. During respiratory acidosis $PO_2$ will be lowered and reverse changes will be produced during respiratory alkalosis. On the other hand, in metabolic acidosis $PO_2$ will be elevated and $PCO_2$ will be lowered by the respiratory compensation, and reverse response will be induced in metabolic alkalosis. Urinary gas tension has many influencing factors than arterial blood and difficult to estimate the tendency of its alterations. Urinary $PO_2$ and $PCO_2$ are not always identical level as venous blood. It is to be altered by blood gas tension, flow rate of urine, metabolic rate of kidney, and Acid-Base status of blood. Particularly countercurrent exchange of oxygen and carbon dioxide in the renal medulla will make larger alteration of gas tension than venous blood. After induction of Acid-Base disturbances [disturbances] arterial and urinary $PCO_2$, $PO_2$, urinary volume, and osmolarity were determined in dogs, and the relationships between arterial and urinary $PCO_2$ , $PO_2$ Acid-Base disturbances, urinary volume, and osmolarity were investigated. 1. During the acute Metabolic and Respiratory disturbances urinary pH did not respond on respiratory origin. However, there were immediate urinary response in pH on metabolic origin. 2. Urinary $PO_2$, $PCO_2$, did not always follow arterial or venous gas tension and Acid-Base disturbance. Urinary $PCO_2$, correlate well with the urinary volume. The larger the urinary volume, $PCO_2$ lowered to the venous level. The smaller the urinary volume, urinary $PCO_2$ tends to be higher. However urinary $PO_2$ did not have any particular correlation with urinary volume. 3. Correlation between urinary $PCO_2$ and $PO_2$ were inversely proportional to arterial blood. Differences of $PCO_2$ between arterial blood and urine also did not have any particular correlation with urinary volume. This may suggest that changes on blood gas tensions can influence on urinary $PCO_2$. 4. There were eminent clear inverse correlation between urinary $PCO_2$ and osmolar concentrations of urine. Above results strongly suggest that partial pressure of gas in urine primarily depend upon counter-current exchanges in renal medullary tissues.

  • PDF

청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석 (Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease)

  • 안재호;김용진
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF

임파유통에 영향을 주는 인자에 관한 실험적 연구 (Various Factors Influencing Thoracic Duct Lymph Flow in the Dogs)

  • 김기환;엄융의
    • The Korean Journal of Physiology
    • /
    • 제9권1호
    • /
    • pp.45-56
    • /
    • 1975
  • Various factors influencing the lymph flow from thoracic duct were investigated in an attempt to evaluate their contributing degree and the mechanisms. Sixteen mongrel dogs weighing between 10 and 16 kg were anesthetized and polyethylene catheters were inserted into the thoracic duct and femoral veins. Arterial blood pressure, heart rate, central venous pressure, lymph pressure and lymph flow were measured under various conditions. Electrical stimulation of left sciatic nerve, stepwise increase of central venous pressure, manual application of rhythmical depressions onto abdomen, injection of hypertonic saline solution and histamine infusion were employed. Measurement of cental venous pressure was performed through the recording catheter inserted into abdominal inferior vena cava. Changes in central venous pressure were made by an air-ballooning catheter located higher than the tip of the recording catheter in the inferior vena cava. Lymph flow from thoracic duct was measured directly with a graduated centrifuge tube allowing the lymph to flow freely outward through the inserted cannula. The average side pressure of thoracic lymph was $1.1\;cmH_2O$ and lymph flow was 0.40 ml/min or 1.9 ml/kg-hr. Hemodynamic parameters including lymph flow were measure immediately before and after (or during) applying a condition. Stimulation of left sciatic nerve with a square wave (5/sec, 2 msec, 10V) caused the lymph flow to increase 1.4 times. The pattern of lymph flow from thoracic duct was not continuous throughout the respiratory cycle, but was continuous only during Inspiration. Slow and deep respiration appeared to increase the lymph flow than a rapid and shallow respiration. Relationship between central venous pressure and the lymph flow revealed a relatively direct proportionality; Regression equation was Lymph Flow (ml/kg-hr)=0.09 CVP$(cmH_2O)$+0.55, r=0.67. Manual depressions onto the abdomen in accordance with the respiratory cycle caused the lymph flow to increase most remarkably, e.g,. 5.5 times. The application of manual depressions showed a fluctuation of central venous pressure superimposed on the respiratory fluctuation. Hypertonic saline solution (2% NaCl) administered Intravenously by the amount of 10 m1/kg increased the lymph flow 4.6 times. The injection also increased arterial blood pressure, especially systolic Pressure, and the central venous pressure. Slow intravenous infusion of histamine with a rate of 14-32 ${\mu}g/min$ resulted in a remarkable increase in the lymph flow (4.7 times), in spite of much decrease in the blood pressure and a slight decrease in the central venous pressure.

  • PDF

동정맥루의 복합성 혈류학 소견이 그 관리에 미치는 영향 (Impact of Complex Hemodynamics to the Management of ArterioVenous(AV) Fistula)

  • 이병붕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.9-10
    • /
    • 2002
  • Human circulatory system between heart and tissue is not directly connected in normal condition but mandatory to go through the capillary system in order to fulfill its physiologic aim to deliver oxygen and nutrients, etc. to the tissue and retrieve used blood together with waste products from the tissue properly. When abnormal connection between arterial and venous system (AV fistula), these two circulatory systems respond differently to the hemodynamic impact of this abnormal connection between high pressure (artery) and low pressure (vein) system. Depending upon the location and/or degree (e.g. size and flow) of fistulous condition, each circulatory system exerts different compensatory hemodynamic response to this newly developed abnormal inter-relationship between two systems in order to minimize its hemodynamic impact to own system of different hemodynamic characteristics. Pump action of the heart can assist the failing arterial system directly to maintain arterial circulation against newly established low peripheral resistance by the AV fistula during the compensation period, while it affects venous system in negative way with increased venous loading. However, the negative impact of increased heart action to the venous system is partly compensated by the lymphatic system which is the third circulatory system to assist venous system independently with different hemodynamics. The lymphatic system with own unique Iymphodynamics based on peristaltic circulation from low resistance to high resistance condition, also increases its circulation to assist the compensation of overloaded venous system. Once these compensation mechanisms should fail to fight to newly established hemodynamic condition due to this abnormal AV connection, each system start to show different physiologic ${\underline{de}compensation}$ including heart and lymphatic system. The vicious cycle of decompensation between arterial and vein, two circulatory system affecting each other by mutually negative way steadily progresses to show series of hemodynamic change throughout entire circulation system altogether including heart. Clinical outcome of AV fistula from the compensated status to decompensated status is closely affected by various biological and mechanical factors to make the hemodynmic status more complicated. Proper understanding of these crucial biomechanical factors iii particular on hemodyanmic point of view is mandatory for the advanced assessment of biomechanical impact of AV fistula, since this new advanced concept of AY fistula based on blomechanical information will be able to improve clinical control of the complicated AV fistula, either congenital or acquired.

  • PDF

히스타민이 혈류역학 및 심전도에 미치는 영향에 관한 연구 (Effects of Histamine on Hemodynamic Parameters and EKG in Dogs)

  • 안승운;김기환;엄융의
    • The Korean Journal of Physiology
    • /
    • 제9권1호
    • /
    • pp.39-43
    • /
    • 1975
  • The effects of histamine on cardiovascular system in 6 dogs were analyzed. Mongrel dogs, 10 to 16 kg in body weight, were anesthetized with Nembutal (30 mg/kg) and arterial blood pressure, heart rate, central venous pressure, electrocardiogram were recorded and measured plasma potassium concentration. Histamine $(100{\mu}g/ml)$ was infused slowly at the rate of 0.25 ml/min through the external jugular vein until BP was 80/60 and maintained restored BP for more than 5 min. The process repeated $4{\sim}5$ times. At each time before and after infusion every items were recorded and measured. 1. Arterial blood pressure was 142/105 (mean 117) mmHg in control and decreased to 90/60 68) after histamine infusion. 2. Heart rate changed from 175 beat/min to 150 and central venous pressure from 6.2 to 5.2 cm $H_2O$. 3. Plasma potassium concentration was 4.3 mEq/L and slightly increased to 4.7 mEq/L but it was not significant statistically. 4. Most characteristic changes revealed in EKG especially in T-waves. Height, Width, Steepness, and Slimness were increased $1.5{\sim}3.7$ times than control level and Pointedness decresed 0.5 times than before.

  • PDF