• Title/Summary/Keyword: Arterial

Search Result 2,604, Processing Time 0.034 seconds

Inadvertent Arterial Catheterization of Central Venous Catheter: A Case Report (중심정맥관의 동맥 내 거치: 증례보고)

  • Oh, Seung-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.292-294
    • /
    • 2015
  • Central venous catheterization is one of the most important procedures for initial resuscitation of hemodynamically unstable patients including multiple trauma patients. Inadvertent arterial placement of the large caliber central venous catheter can results in resuscitation failure as well as unnecessary invasive treatment. Here, we report an arterial puncture during central venous catheterization which may lead to inadvertent arterial catheterization. We recommend that arterial catheterization should be evaluated before dilator insertion during Seldinger's method. Ultrasound can help in preventing the inadvertent arterial catheterization of central venous catheter.

  • PDF

Surgical Treatment of Peripheral Arterial Disease -Clinical Analysis Of 55 Cases- (말초동맥질환의 외과적치료 -55예의 임상분석-)

  • 김한용
    • Journal of Chest Surgery
    • /
    • v.24 no.12
    • /
    • pp.1173-1184
    • /
    • 1991
  • This report is a review of 55 cases of peripheral arterial disease, who were treated at the department of thoracic and cardiovascular surgery, Masan Koryo General Hospital from January, 1986 to December, 1990. The result are summerized as follows ; 1. The incidence of peripheral arterial disease were as follows that : Arterial injury was in 21 cases(38.2%), arteriosclerosis oblitrans 18cases(32.7%), thromboembolism 9cases(16.4%), Buerger's disease was in 7cases(12.7%). 2. Overall male to female ratio was 6.8 : 1, the prevalent age was 3rd and 4th decade in arterial injury, 7th and 8th decade in atherosclerosis and thromboembolism and 5th and 6th decade in Buerger's disease. 3. The farmer was the first ranked occupation of these patients with chronic occlusive arterial disease, which was composed of 17 cases (68%). 4. 23 cases of patients with chronic occlusive disease has been smoking and most of them have been smoking over 10 years. 5. The clinical symptoms in acute and chronic arterial obstruction were pain, claudication, gangrene and coldness in order. 6. The duration of symptom of chronic arterial occlusive disease was less 1 years in 15 cases(60%). 7. The lower extremity were more affected than upper extremity in peripheral arterial disease. 8. The cause of arterial injury was traffic accident 9 cases(42.9%) stab wound 8 cases (38.1%), postangiography 2 cases(9.5%) and belt injury 1 case. 9. The etiologic factors of acute arterial occlusion was arterial fibrillation myocardial ischemia and postangiography in order. 10. Lumber sympathectomy in Buerger's disease, artificial bypass graft in atherosclerosis and thromboembolctomy in thromboembolism, end to end with vein graft in arterial injury were performed frequently. 11. Conclusively overall result was satis factory but 3 cases was below knee amputated after operation of chronic arterial occlusive disease.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Concurrent Intracranial and Extracranial Arterial Aneurysms: Report of Three Cases

  • Shin, Seung-Ryeol;Kim, Tae-Sun;Lee, Jung-Kil;Lee, Je-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.223-227
    • /
    • 2005
  • Systemic multiple aneurysms are rare, and an association between intracranial and visceral arterial or abdominal aortic aneurysm in the same patient is a very rare occurrence. We report herein three such cases. In one case, aneurysms of the right internal carotid artery(ICA) and the right middle cerebral arterial bifurcation(MCAB) coexisted with the inferior pancreaticoduodenal arterial pseudoaneurysm and two ileal arterial aneurysms. In another case, the patient had the A-com arterial aneurysm and the right renal arterial aneurysm. And in the other patient, he had the right vertebral artery dissecting aneurysm with the abdominal aortic aneurym. Initially, all patients were referred to our hospital with subarachnoid hemorrhage(SAH), and thereafter first two patients developed visceral arterial aneurysm rupture in the course of hospital stay and in the last patient, the abdominal aortic aneurysm was detected incidentally during carotid angiogram for Guglielmi detachable coil(GDC) embolization of vertebral dissecting aneurym. After thorough review of our cases together with pertinent literatures, we emphasize the possibility of underlying extracranial aneurysms in ruptured intracranial arterial aneurysm patient and it's uncommon but fatal complication.

2-dimensional Measurement of Arterial Pulse by Imaging Devices (촬상소자를 이용한 맥동의 2차원 계측)

  • Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

Analysis of Accident Factors at Arterial Roads Using Tobit Model (Tobit 모형을 이용한 간선도로 사고 요인 분석)

  • Kim, Kyung Hwan;Park, Byung Ho
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.131-138
    • /
    • 2013
  • PURPOSES : The intents of the study are to identify the accident factors and to demonstrate the potentials of tobit model as a tool to study the number of accidents on arterial roads segments. METHODS : This paper uses a tobit regression as a methodology to analyze the factors affecting the number of accidents. In pursuing the above goal, this study gives particular attentions to analyzing the data of 2,446 accidents (1,610 in major arterial roads and 836 in minor arterial roads) occurred on arterial roads in 2007 to 2010. RESULTS : First, 3 accident models which were classified by total arterial roads, major arterial roads and minor arterial roads, and were all statistically significant were developed. Second, the exclusive right-turn lane as common variable, and the number of accident, traffic volume, number of lanes, link length, rate of median, number of entrances, number of pedestrian crossings, number of curves, number of bus stops and exclusive left-turn as specific variables of the models were selected. Finally, the paired sample t-test could not be rejected the null hypotheses of three types of models. CONCLUSIONS : Using data from vehicle accidents on arterial roads, the estimation results show that many factors related to roadway geometrics and traffic characteristics significantly affect to the number of accidents.

Development of an integrative cardiovascular system model including cell-system and arterial network (세포-시스템 차원의 혈류역학적 심혈관 시스템 모델의 개발)

  • Shim, Eun-Bo;Jun, Hyung-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.542-546
    • /
    • 2008
  • In this study, we developed a whole cardiovascular system model combined with a Laplace heart based on the numerical cardiac cell model and a detailed arterial network structure. The present model incorporates the Laplace heart model and pulmonary model using the lumped parameter model with the distributed arterial system model. The Laplace heart plays a role of the pump consisted of the atrium and ventricle. We applied a cellular contraction model modulated by calcium concentration and action potential in the single cell. The numerical arterial model is based upon a numerical solution of the one-dimensional momentum equations and continuity equation of flow and vessel wall motion in a geometrically accurate branching network of the arterial system including energy losses at bifurcations. For validation of the present method, the computed pressure waves are compared with the existing experimental observations. Using the cell-system-arterial network combined model, the pathophysiological events from cells to arterial network are delineated.

  • PDF

Cerebral Arterial Stenosis in Patients with Spontaneous Intracerebral Hemorrhage

  • Chung, Pil-Wook;Won, Yu Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.511-517
    • /
    • 2017
  • Objective : Spontaneous intracerebral hemorrhage (ICH) and ischemic stroke share common vascular risk factors such as aging and hypertension. Previous studies suggested that the rate of recurrent ICH and ischemic stroke might be similar after ICH. Presence of cerebral arterial stenosis is a potential risk factor for future ischemic stroke. This study investigated the prevalence and factors associated with cerebral arterial stenosis in Korean patients with spontaneous ICH. Methods : A total of 167 patients with spontaneous ICH were enrolled. Intracranial arterial stenosis (ICAS) and extracranial arterial stenosis (ECAS) were assessed by computed tomography angiography. Presence of ICAS was defined if patients had arterial stenosis in at least one intracranial artery. ECAS was assessed in the extracranial carotid artery. More than 50% luminal stenosis was defined as presence of stenosis. Prevalence and factors associated with presence of ICAS and cerebral arterial stenosis (presence of ICAS and/or ECAS) were investigated by multivariable logistic regression analysis. Results : Thirty-two (19.2%) patients had ICAS, 7.2% had ECAS, and 39 (23.4%) patients had any cerebral arterial stenosis. Frequency of ICAS and ECAS did not differ among ganglionic ICH, lobar ICH, and brainstem ICH. Age was higher in patients with ICAS ($67.6{\pm}11.8$ vs. $58.9{\pm}13.6years$ p=0.004) and cerebral arterial stenosis ($67.9{\pm}11.6$ vs. $59.3{\pm}13.5years$, p<0.001) compared to those without stenosis. Patients with ICAS were older, more frequently had diabetes, had a higher serum glucose level, and had a lower hemoglobin level than those without ICAS. Patients with cerebral arterial stenosis were older, had diabetes and lower hemoglobin level, which was consistent with findings in patients with ICAS. However, patients with cerebral arterial stenosis showed higher prevalence of hypertension and decreased kidney function compared to those without cerebral arterial stenosis. Multivariable logistic regression analyses showed that aging and presence of diabetes independently predicted the presence of ICAS, and aging, diabetes, and hypertension were independently associated with presence of cerebral arterial stenosis. Conclusion : 19.2% of patients with spontaneous ICH had ICAS, but the prevalence of ECAS was relatively lower (7.2%) compared with ICAS. Aging and diabetes were independent factors for the presence of ICAS, whereas aging, hypertension, and diabetes were factors for the cerebral arterial stenosis.

Endothelium-Dependent Vasorelaxation Effects of Rubus Coreanus extract on Rabbit Carotid Artery (복분자(覆盆子)의 내피세포의존성 혈관이완효과)

  • Chin, Jun Ho;Park, Sun Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.437-445
    • /
    • 2013
  • This study was investigated to evaluate the vasorelaxant effect of Rubus coreanus(RC) extract on contracted rabbit carotid artery and its mechanism. To study the effect of RC extract on contracted rabbit carotid arterial strips, arterial strips with intact or damaged endothelium were used for experiment using organ bath. The pre-contracted arterial strips with norepinephrine(NE) or potassium chloride(KCl) was treated with various concentrations of an extract of RC(0.01, 0.03, 0.1, 0.3 and 1.0 $mg/m{\ell}$). To determine the mechanisms of RC-induced vasorelaxant, RC extract was infused into contracted arterial rings which had been pretreated by indomethacin(IM), tetraethylammonium chloride(TEA), $N{\omega}$-nitro-L-arginine (L-NNA), methylene blue(MB). And calcium chloride(Ca) 1 mM was infused into precontracted arterial ring induced by NE or KCl after treatment of RC extract in $Ca^{2+}$-free krebs solution. Cytotoxic activity of RC extract on human umbilical vein endothelial cell(HUVEC) was measured by MTT assay, and nitric oxide(NO) prodution was measured by Griess reagent. RC extract revealed significant relaxation on NE-induced arterial contraction, but didn't relax on KCl-induced arterial contraction. RC extract also had an effective relaxation to the intact endothelium arterial ring, but not the damaged endothelium arterial ring. Treatment of IM, TEA, L-NNA, MB reduced the relaxation of RC extract. Pretreatment of RC extract inhibited the contraction by influx of extracellular $Ca^{2+}$ in contracted arterial ring induced by NE, but it didn't work the contraction by influx of extracellular $Ca^{2+}$ in contracted arterial ring induced by KCl in $Ca^{2+}$-free krebs solution. RC extract increased nitric oxide production on HUVEC. This study indicated that the relaxation effect of RC extract on contracted rabbit carotid artery is related with NO-cGMP pathway, EDHF, prostacyclin.

Wireless Optical Fiber Interferometer Arterial Pulse Wave Sensor System (무선 기반의 광섬유 간섭계형 맥파센서 시스템)

  • Park, Jaehee;Shin, Jong-Dug
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.439-443
    • /
    • 2013
  • A wireless optical fiber interferometer arterial pulse wave sensor system is developed for remote sensing. The wireless optical fiber sensor system consists of Zigbee communication modules and an optical fiber interferometer arterial pulse wave sensor. The optical fiber arterial pulse wave sensor is an in-line Michelson interferometer enclosed with steel reinforcement in a heat-shrinkable tube. The Zigbee communication modules are composed of an ATmega128L microprocessor and a CC2420 Zigbee chip. The arterial pulse waves detected by the optical fiber sensor were transmitted and received via the Zigbee communication modules. The experimental results show that the wireless optical fiber sensor system can be used for monitoring the arterial pulse waves remotely.