• Title/Summary/Keyword: Array test

Search Result 812, Processing Time 0.026 seconds

THERMAL BALANCE MODELLING AND PREDICTION FOR A GEOSTATIONARY SATELLITE (정지궤도 위성의 열평형 시험 모델링 및 예비 예측)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.142-147
    • /
    • 2009
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be tested under vacuum condition and very low temperature in order to verify thermal design of COMS. The test will be performed by using KARI large thermal vacuum chamber, which was developed by KARI, and the COMS will be the first flight satellite tested in this chamber. The purposes of thermal balance test are to correlate analytical model used for design evaluation and predicting temperatures, and to verify and adjust thermal control concept. KARI has plan to use heating plates to simulate space hot condition especially for radiator panels such as north and south panels. They will be controlled from 90K to 273K by circulating GN2 and LN2 alternatively according to the test phases, while the shroud of the vacuum chamber will be under constant temperature, 90K, during all thermal balance test. This paper presents thermal modelling including test chamber, heating plates and the satellite without solar array wing and Ka-band reflectors and discusses temperature prediction during thermal balance test.

  • PDF

Instrumentation of Thermo-sensitivity Test of Well Points, a Pilot Report (정혈 지열감도 측정법의 객관화 -기기 개발 및 시험 측정 결과 보고-)

  • Lee, Byung-Hoon;Lee, Sang-Hoon;Kim, Ki-Wang
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.133-141
    • /
    • 2011
  • Objectives : Although the thermo-sensitivity test in Well points in 12 Meridians(井穴知熱感度測定法) has been used for several decades, it is still performed by a manual way, and lack in objectivity consequently. To make it more objective, accurate and convenient test, we have developed a novel system to test thermo-sensitivity in Well points. Methods : To enhance the blindness of the test, we made a shielded system which give heat to some fingers of subjects in random way. To perform the test in quantitative manner, we developed a fully automated, computer-controlled system composed of heating bulbs and response button array. Results : The developed system showed linearity in heating the finger phantom. It also gave acceptable but interesting features in pilot tests with several young adult subjects. Conclusions : By the developed system, we could improve objectivity and convenience of the thermo-sensitivity test in Well points.

Performance Analysis of a Smart Antenna Test-bed Operating in a IS2000 Environment (IS2000 환경에서 스마트 안테나 Test-bed의 성능분석)

  • 임흥재;최승원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1061-1070
    • /
    • 2002
  • In this paper, we present a performance analysis of the smart antenna test-bed operating in a IS2000 1x through a test-bed that has been implemented on a DSP(TMS320C6711) board. The test-bed consists of a PC (for generating the RX data), beam-former(i.e., a stand-alone PCB for weight computation), and an interfacing module. The performance improvements compared to a normal base station system consisting of a single antenna are shown in terms the BER(bit error rate) in the wide-band CDMA channel.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

Performance Experiment of H-120 Class Fire Damper for Offshore (해양플랜트용 H-120 등급 방화 댐퍼의 성능 실험)

  • Park, Chang-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.5
    • /
    • pp.425-430
    • /
    • 2017
  • This study propose CAE analysis of fire damper and design of the damper control system. Through the design of the damper system for ANSYS-CFX heat transfer. As a result of the analysis, continuance equation of the damper control. Climate system. Finaily, We have obtained a fire damper solution by using orthogonal array. The fire damper of the set of fixture and alveolus are made by using a CAE software. Also, the optimum design offshore structures. The new H-120 class fire damper was designed. In the near future, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500mm on the unexposed side as specified test standard.

Demosaicking Method using High-order Interpolation with Parameters (매개변수를 갖는 고차원 보간법을 이용한 디모자이킹 기법)

  • Lee, Yeon-Kyung;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1276-1282
    • /
    • 2013
  • This paper presents a demosaicking method based on high-order interpolation with parameters. Demosaicking is an essential process in capturing color images through a single sensor-array. Thus, a lot of methods including the Hamilton-Adams(HA) method has been studied in this literature. However, the image quality depends on various factors such as contrast and correlation in color space; existing algorithms depend on test images in use. Consequently, a new test image set was suggested to develop demosaicking algorithms properly. According to previous studies, the HA method shows high performances with the new test data set. In this paper, we improve the HA method using high-order interpolation with parameters. Also, we provide an analysis and formulations for the proposed method. To evaluate our method, we compare our method with the existing methods both objectively and subjectively. The experimental results indicate that the proposed method is superior to the existing methods.

Acoustic Noise Measurement for the Wind Turbine Blade by Using Time-domain Beamforming (시간영역 빔포밍을 사용한 풍력터빈 축소모델 소음원 측정)

  • Cho, Tae-Hwan;Kim, Cheol-Wan
    • New & Renewable Energy
    • /
    • v.5 no.2
    • /
    • pp.25-30
    • /
    • 2009
  • The wind tunnel test to identify the acoustic noise source position of the wind turbine blade was conducted in KARI low speed wind tunnel. Microphone array and time-domain beamforming methodology was applied to this study. To reduce the data processing time, a modified beamforming method with a criteria between calculation time step and grid size for rotating angle in the cylinderical coordinate system was proposed. The test results shows that the data processing time to identify the noise source position was reduced to 20% compared with conventional method. And the dominant noise source of the blade moves from inboard to blade tip as the frequency increases.

  • PDF

Implementation of ZUPT on RPA Navigation System for GNSS Denied Ground Test

  • Shin, Hyeoncheol
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.2
    • /
    • pp.125-129
    • /
    • 2020
  • In this paper, Zero velocity UPdaTe (ZUPT) is implemented on the navigation system of Remotely Piloted Aircraft for GNSS denied environment. RPA's navigation system suffers from lack or loss of satellite signal while maintenance or ground test inside a hangar. Although some of the hangars install GPS repeaters for indoor tests, the anti-jamming equipment with array antenna blocks the repeater signal regarding them as hostile jamming signal. With ZUPT, an aircraft navigation system can be tested free from the divergence of navigation solution without line-of-sight satellites. The designed ZUPT aided centralized Kalman Filter is implemented on the Embedded GPS&INS and simulated with Captive Flight Test data. The simulation result shows stable navigation solution without GNSS updates.

Long-term Experiments of the Cooling/Cleaning on the surface of the PV Power Array (태양광발전 어레이 표면의 냉각/세정에 대한 장기 실증 실험)

  • Han, Jun-Sun;Kim, Yi-Hyun;Ji, Hee-Kwan;Yu, Sang-Phil
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.248-254
    • /
    • 2012
  • In the situation of expanding domestic solar power supply business long-term performance modeling of a proposed solar-cooling and cleaning system to increase electromotive force and light transmission is carried out to test the effectiveness of the system. To test the effectiveness of the system, the data which comparing the solar power planet installing the system to not installing at the same time is used. A difference between the utilization factor of each comparison group were recorded. Approximately from one year to two years Field Test was performed, Result of apply to cooling/cleaning technology, Each of plant by From least 7 percent up to 16 percent utilization factor increased, and the cooling / cleaning is output through improved as a result of the determined.

  • PDF

TEST MODEL OF MILLIMETER-WAVE IMAGING RADIOMETER EQUIPMENT (MIRAE)

  • Lee, Ho-Jin;Kim, Won-Gyum;Seong, Jin-Taek;Kim, Dae-Suk;Na, Kyoung-Tae;Jung, Min-Kyoo;Chang, Yu-Shin;Kim, Soon-Tae;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.365-368
    • /
    • 2007
  • Millimeter-wave (MMW) imaging radiometer systems have an attractive advantage to obtain an image through low visibility weather conditions such as fog, clouds and light rain compared with visible and infrared imaging systems. Many countries have developed a various kinds of MMW imaging radiometers for the aim of low cost and high performance. In Korea, Millimeter-wave Imaging RAdiometer Equipment (MIRAE) has been developed since the end of 2006. Recently the development of some modules was finished for the test model. This paper describes the design and development of the MIRAE. In addition, the test results of its manufactured modules are presented.

  • PDF