• 제목/요약/키워드: Array coil

검색결과 94건 처리시간 0.021초

다중센서 신호특성 최적화를 통한 와전류검사 신뢰성 개선연구 (The Study on Reliability Improvement in Eddy Current Inspection by Signal Characteristic Optimization of Multi-coil Array Probe)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제14권2호
    • /
    • pp.60-64
    • /
    • 2010
  • This paper introduces reliability improvement and time saving in eddy current inspection by signal characteristic optimization of multi-coil eddy current array probe. In the past, Multi-coil array probe and single probe were used for the gas turbine rotor surface inspection & defect evaluation. The multi-coil array probe was used for the broad area inspection. But the signal deviations among multi-coil array probe are maximum 28% in commercial probe. This differences were considered to impedance differences among coils, so it is very difficult to evaluate exact defect size. The signal deviations among multi-coil array probe are maximum 28% in commercial probe. So, single coil inspection was used for exact defect sizing. The purpose of this study is to improve signal deviations of multi-coil array probe. The introduced new technology can improves this deviation by adjusting input voltage in each coil. At first, apply same voltage in each coil and collect signal amplitude of each coil. And calculate new input voltage based on signal amplitude of each coil. If the signal amplitude deviation is within 5% among multi-coil array probe, the signal amplitude of multi-coil array probe is reliable. The proposed technology gives 2% signal deviation among multi-coil array probe. The proposed new technology gives reliability improvement and inspection time saving in eddy current inspection.

척추 MRI를 위한 One-Channel Phased-Array Quadrature RF 코일 (One-Channel Phased-Array Quadrature RF Coil for Spine Magnetic Resonance Imaging)

  • 양윤정;김선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.129-132
    • /
    • 1998
  • 이 논문의 목적은 척추 영상을 위한 One-channel phased-array quadrature RF 코일을 개발하는 것이다. 두 개의 수직방향 RF 코일을 조합하여 만든 Quadrature RF코일은 한 개의 코일을 쓰는 것에 비해 배의 signal-to-noise ratio(SNB) 향상을 얻울 수 있다. Phased-array quadrature RF 코일에서는 코일 element의 크기를 줄임으로써 SNR을 더욱 향상시킬 수 있다. 이에 따라 줄어드는 코일의 Coverage를 유지하기 위해 phased-array 코일에서는 여러 set의 작은 코일을 사용한다. 다음과 같은 두가지 방법으로 Phased-array의 각 코일간의 간섭 현상을 제거했으며 SNR을 개선하였다. (1)인접한 코일을 적당한 간격으로 겹쳐지게 함으로써 상호 인덕턴스를 영으로 만든다. (2)Pro-amp를 코일에 바로 붙임으로써 커플링 회로에서의 SNR loss를 방지하고 그 다음 단에서 코일 사이의 phase차를 보정한다. 이 논문에서는 Receive-only mode의 Phased-array quadrature RF 코일을 개발하여 팬텀과 인체 척추의 영상촬영을 통하여 그 성능을 입증하였다.

  • PDF

자기공명영상검사 시 Array coil에서 element를 선택하여 신호를 수집하는 기법의 유용성 (Usefulness of the Technique of Collecting Signals by Selecting Elements from RF Receive Phase Array Coil in Magnetic Resonance Imaging)

  • 최관우;손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제18권6호
    • /
    • pp.461-466
    • /
    • 2018
  • 본 연구는 자기공명영상에서 array coil을 이용한 부분영역의 영상화 시 SNR을 증가시킬 수 있는 방안으로 element를 선택하여 신호를 수집하는 기법의 유용성에 대해 알아보고자 하였다. 연구방법은 array coil에 두 개의 원통형 fluid phantom을 나란히 위치시킨 다음, 부분영역인 한 개의 fluid phantom 영상화 시 element 전체를 사용하여 신호를 수집하는 경우와 선택한 경우로 나누어 SNR을 비교하였다. 연구결과, T1, T2 강조영상 모두 element를 선택하여 신호를 수집하는 경우가 전체를 사용한 경우보다 T1강조영상은 5.49%, T2강조영상은 14.64% 유의하게 증가하였다. 결론적으로 array coil을 이용한 부분영역의 영상화 시 element를 선택하여 신호를 수집하면 손쉽게 SNR을 증가시킬 수 있으리라 판단된다.

자기공명영상촬영을 위한 Phased-Array Quadrature RF 코일 (Phased-Array Quadrature RF Coil for Magnetic Resonance Imaging)

  • 김선경;양윤정;이덕래;안창범;이흥규;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.227-229
    • /
    • 1997
  • A new phased-array quadrature RF coil for one or two RF acquisition channels is developed for spine MR imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by $"\sqrt{2}"$ using two orthogonal RF coils in combination [1]. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of RF coil elements with a reduced size and coverage for each element. Two new schemes are proposed for the new phased-array quadrature RF coil as follows : (1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive- only mode. It has been tested through phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.238-243
    • /
    • 2017
  • In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가 (Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI)

  • 조재환
    • 디지털콘텐츠학회 논문지
    • /
    • 제11권3호
    • /
    • pp.283-290
    • /
    • 2010
  • 1.5T에서 경직장 코일과 3.0T의 위상 배열 코일을 이용하여 신호대 잡음비를 비교하여 3.0T의 위상 배열 코일의 유용성을 제시한다. 전립선암으로 진단받은 환자 40명을 대상으로 1.5T MR scanner에서는 경직장 표면 코일과 3.0T MR scanner에서는 위상 배열 코일을 이용하여 T2 강조 영상, T1 강조영상, 확산 강조 영상을 각각 획득 후 전립선의 Central Zone(CZ)과 Peripheral Zone(PZ)에서 Right Peripheral Zone(PZ)과 Left Peripheral Zone(PZ) 세 부위에서 신호 강도(signal intensity)측정을 하였다. 정량적 분석방법으로 관심영역의 신호대 잡음비(signal to noise ratio)를 구하고 평균화 하여 1.5T MR scanner로 획득한 그룹과 3.0T MR scanner로 획득한 그룹에서의 신호대 잡음비를 비교하였다. 3.0T MR scanner에서 위상 배열 코일을 사용한 경우 1.5T MR scanner에서 경직장 코일을 사용한 경우보다 신호대 잡음비가 증가됨을 알 수 있었다.

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • 비파괴검사학회지
    • /
    • 제26권1호
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

Halbach Magnetic Circuit for Voice Coil Motor in Hard Disk Drives

  • Choi, Young-Man;Ahn, Da-Hoon;Gweon, Dae-Gab;Jeong, Jae-Hwa
    • Journal of Magnetics
    • /
    • 제15권3호
    • /
    • pp.143-147
    • /
    • 2010
  • Rotary-type voice coil motors are widely used as actuators in hard disk drives. The recent trend toward higher density and smaller form factors in data storage devices requires performance improvement of the voice coil motor. In this study, we introduce a Halbach magnet array to the voice coil motor in order to increase the force generation. The Halbach magnetic circuit outperforms the conventional magnetic circuit due to the confined magnetic flux. To investigate the performance of the Halbach magnetic circuit, we analyze air gap flux density with the various shapes and thickness of the magnets using 3-dimensional finite element analysis. Consequently the optimum shape of the Halbach magnetic circuit is proposed. Simulations and experimental results proved effectiveness of the proposed magnet array in the voice coil motor for a commercial hard disk drive.

6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도 (Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils)

  • 최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.699-706
    • /
    • 2018
  • 본 연구는 array 코일을 이용한 검사 시 코일의 위치변화에 따른 신호강도를 측정하여 영상의 신호강도가 급격히 저하되지 않는 기준 방향과 거리를 제시함으로써, 동일선상에 코일들이 위치하지 않았을 경우 신호강도가 저하되는 문제점을 개선해 보고자 하였다. 연구방법은 두 부분으로 나눠져 있는 array 코일에 multi-purpose MRI 팬텀을 위치시킨 다음 array 코일의 앞부분을 상, 하, 좌, 우 네 방향으로 중심에서 2 cm 씩 10 cm 까지 이동하며 영상을 획득한 후 신호강도를 측정하여 비교평가 하였다. 연구결과, T1, T2 강조 영상 모두 상 방향을 제외한 하 방향과 좌, 우 방향의 위치변화가 2 cm 이내인 경우 기준 신호강도인 중심의 신호강도와 유의한 차이가 없어 동일한 신호강도를 나타냄을 알 수 있었다. 결론적으로 array 코일을 이용한 검사 시 여러 가지 원인에 의해 동일선상에 코일들을 위치시킬 수 없을 경우 상 방향을 제외한 나머지 방향의 위치변화를 중심에서 2 cm 이내로 설정한다면 위치변화로 인해 신호강도가 저하되는 문제점을 개선할 수 있다.

3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램 (A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling)

  • ;;;조민형;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.107-119
    • /
    • 2014
  • 목적: 실제 촬영 결과와 전자기 모의실험 결과를 시각적으로 비교함으로써 위상배열코일을 이루는 모든 코일 요소의 감도를 효과적으로 검증할 수 있는 소프트웨어를 개발하였다. 대상과 방법: 위상배열코일검증기(PACE)라 불리는 프로그램을 MATLAB과 C언어를 이용해 구현하였다. 위상배열 코일검증기는 코일 소자의 3차원 형상 모델 구축, FDTD 모의실험 결과의 수용, 보통의 직각좌표계 및 코일면에 기준하는 직각좌표계 상에서 각기 코일 소자 감도를 도시하는 기능을 가지고 있다. 위상배열코일의 3차원 형상 모델을 구축하기 위해 바늘침 모양의 3차원 전자기 위치추적기를 사용하였다. 3차원 형상 모델을 만든 뒤, 이 형상 모델 데이터를 FDTD 모의실험 장치에 보낼 수 있게 하였다. 결과: 3차원 전자기 위치추적기를 이용해 실제 실험에 사용된 위상배열코일과 FDTD 모의실험에 사용된 위상배열코일 모델을 정확하게 일치시킴으로써, 각기 코일 소자의 공간적 감도를 평가할 때 모의실험 결과와 촬영실험 결과 사이 정확한 비교가 가능하게 되었다. 모의실험과 실제 촬영실험에는 36 채널의 헬멧형 위상배열코일을 사용하였다. MRI 촬영 대상체로는 FDTD 모의실험의 모델과 같은 크기와 형상을 가진 원통형 팬텀을 사용하였다. 개발한 프로그램에서는 위상배열코일의 성능을 편리하게 평가하기 위해 관심 코일 소자를 쉽게 선택할 수 있게 하였다. 결론: 개발한 위상배열코일 성능 검증 프로그램은 위상배열코일의 개발 및 정기적인 유지보수에 사용될 수 있을 것으로 기대한다.