• Title/Summary/Keyword: Arm Posture

Search Result 170, Processing Time 0.026 seconds

The Effects of Screen Smart Devices on the Neck Flexion Angle

  • Lee, Jun Cheol;Kim, Kyung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1051-1055
    • /
    • 2016
  • The purpose of this study was to investigate the effect of the screen size of smart devices on the bending angle of the cervical spine. The subjects of this study were 30 healthy adults(15 men and 15 women) who used smartphones and tablet PC(personal computer). The changes in the bending angle of the upper and lower cervical spine were measured in the subjects after they had used a smartphone and a tablet PC for 300 seconds each. To make sure that all subjects began in the same starting position, an angle-measuring instrument was used to set the angles of the ankle, knee, hip, and arm joints to 90 degree. The subjects were asked to keep the trunk straight. They were asked to hold a smartphone in their hand and to bend their neck so that they could look down at the screen. Once they began using the smartphone in this manner, they were free to change their posture. We used a paired t-test to compare the bending angle of the cervical spine on subjects who used smartphones and tablet PC in the long-term and short-term there production error of cervical and the significance level was cervical. The results showed that, when using a smartphone and a tablet PC for 300 seconds, there was no significant difference in the bending angle of the upper cervical spine(p>.05), although there was a significant difference in the bending angle of the lower cervical spine(p<.05).

A Study on Excavation Path Design of Excavator Considering Motion Limits (실차의 거동한계를 고려한 굴착기의 굴착 경로설계 연구)

  • Shin, Dae Young
    • Journal of Drive and Control
    • /
    • v.18 no.2
    • /
    • pp.20-31
    • /
    • 2021
  • An excavator is a construction machine that can perform various tasks such as trenching, piping, excavating, slope cutting, grading, and rock demolishing. In the 2010s, unmanned construction equipment using ICT technology was continuously developed. In this paper, the path design process was studied to implement the output data of the decision stage, and the path design algorithm was developed. For example, the output data of the decision stage were terrain data around the excavator, excavator mechanism information, excavator hydraulic information, the position and posture of the bucket at key points, the speed of the desired bucket path, and the required excavation volume. The result of the path design was the movement of the hydraulic cylinder, boom arm, bucket, and bucket edge. The core functions of the path design algorithm are the function of avoiding impact during the excavation process, the function to calculate the excavation depth that satisfies the required excavation volume, and the function that allows the bucket to pass through the main points of the excavation process while maintaining the speed of the desired path. In particular, in the process of developing the last function, the node tracking method expressed in the path design table was newly developed. The path design algorithm was verified as this path design satisfied the JCMAS H02 requirement.

Effects of Yoga on Pain, Function, and Depression in Individuals with Nonspecific-Low Back Pain

  • Song, Seonghyeok;Choi, Youngam;Cho, Namjeong;Kim, Hyun-Joong
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.165-171
    • /
    • 2022
  • Objective: Nonspecific low back pain (NSLBP) is experienced worldwide by many age groups. Yoga is recommended as an exercise to reduce back pain and stress because it is a breathing exercise, posture, and meditation as key elements. The aim of this study is to compare the effects of yoga and stabilization exercise on pain intensity, function, and depression. Design: An open-label, parallel arm, randomized controlled trial Methods: Twenty-four participants were allocated to the experimental and the control group in a ratio of 1:1. Yoga (experimental group) and stabilization exercise (control group) were received twice a week for 6 weeks Participants were assessed at baseline and post-intervention for pain intensity (numeric pain rating scale), function (Aberdeen low back pain scale, flexibility,and strength), and depression (Beck depression inventory). Results: When the experimental group (Yoga) and control group (stabilization exercise) were performed twice a week for 6 weeks, numeric pain rating scale, Aberdeen low back pain scale, and flexibility in post-intervention showed significant improvement in both groups (P<0.05), However, in all variables, the experimental group showed a positive benefit compared to the control group (P<0.05). Conclusions: The results of this study show that yoga has more positive benefits compared to stabilization exercise in pain intensity, function, and depression in individuals with NSLBP.

Design of a Prototype Jacket for Upper Extremity Load Reduction (상지 부하 감소를 위한 기능성 상의 프로토타입 디자인)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.4
    • /
    • pp.613-623
    • /
    • 2022
  • This study developed a functional prototype jacket designed to reduce loads on the upper extremities of workers performing repetitive motions in the same posture for extended periods of time. Dynamic taping lines were applied to the upper extremities, and three dimensional (3D) supporters were inserted in the abdomen and back waist areas corresponding to the core muscles. Clothing pressure on the upper-extremity dynamic taping lines was set to two levels (proto P1 and proto P2), and the 3D supporters were designed in three types (proto FW, proto FW/BW, proto FW/BW/BBX). According to the subjective pressure perceived on each part of the upper extremities, the level proto P1 pressure was preferred. The proto FW/BW/BBX 3D supporter was rated as excellent, and the perceived pressure was ranked as satisfactory. The prototype jacket performed upper-extremity load reduction when the upper-extremity clothing-pressure level was set to 1.8 kPa, 2.1 kPa, and 2.4 kPa on the upper arm, forearm, and wrist regions, respectively, and when 3D supporters were installed in the abdomen and back of the waist with the addition of a back band.

Effect of Elastic Aids (Bands) on Functional Reach Test in Patients with Spinal Cord Injury: Pilot Study

  • Jong Ho Kang;Tae Sung Park
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.317-320
    • /
    • 2022
  • Purpose: This study aimed: to confirm the balance ability of patients with spinal cord injury in the sitting state through a functional reach test using an elastic aid; and to propose a balance improvement plan. Methods: The study evaluated seven patients with spinal cord injury who could maintain a sitting posture through minimum assistance. A functional reach test was performed before and after wearing an elastic aid while sitting on a chair, and the effects before and after use of the elastic aid were compared and analyzed through a motion analyzer. Results: In the functional reach test, the forward movement distance of the hand was 97.45 mm before wearing the elastic aid, but significantly increased to 131 mm after wearing the aid (p<0.05). Corresponding forward movement distances for the shoulder were 81.26 mm and 113 mm (p<0.05 for the increase). There was no statistically significant change in lateral functional arm extension. Conclusion: It was confirmed, through a functional reach test, that trunk stability in patients with spinal cord injury increased with use of an elastic aid. In future, more efficient rehabilitation treatment programs will be possible if trunk stability in patients with spinal cord injury is improved by using elastic aids, and if various exercise treatments are also included in the rehabilitation programs.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Musculoskeletal Workload Evaluation in Physical Therapist (물리치료사의 근골격계 부담작업 유해요인 조사)

  • Sung, Youn-Bum;Seo, Hyung-Seok;Lee, Jung-Ho;Park, Young-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3999-4008
    • /
    • 2012
  • This study investigated the symptoms of work-related musculoskeletal disorder(WMSDs) for physical therapists who have different work duties. We analyzed the symptoms in the musculoskeletal system and the degree of work-harmfulness by the survey of the symptom in the musculoskeletal system and rapid upper limb assessment(RULA) for pain control group(n=56), adult exercise group(n=53), and pediatric exercise group(n=22). As a result, 69.6% of the pain control group, 84.9% of the adult exercise group, 81.8% of the pediatric exercise group show the observable symptom. The adult exercise group has the biggest work load per hour in the final wrist & arm score of the ergonomic risk assessment using RULA. The action level of the pain control group is $3.0{\pm}0.9$; the Action Level of adult exercise group is $3.3{\pm}0.6$; the Action Level of the pediatric exercise group is $3.2{\pm}0.8$, and so it is shown that the adult exercise group has a problem of working posture. It is considered that devices and education system for preventing from WMSDs should come into wide use.

The Effects of Hand Grip Force on Shoulder Muscle Activity in Two Arm Posture (파악력의 강도가 두 가지 팔 자세에서 어깨근육 근활성도에 미치는 영향)

  • Jang, Hyun-Jeong;Kim, Ji-Seon;Choi, Jong-Duk;Kim, Suhn-Yeop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1229-1237
    • /
    • 2012
  • This study aimed to investigate the effect of hand grip force on the activity of shoulder muscles in 2 arm postures. The muscle activity of the upper trapezius, lower trapezius, infraspinatus, anterior deltoid, and posterior deltoid muscles in 22 healthy subjects (11 men and 11 women) were measured using surface electrodes during 4 hand gripping tasks (0%, 30%, 50%, and 70% of maximum voluntary contraction) in 2 shoulder positions (neutral position and $90^{\circ}$ elevation position). Among changing grip force significantly differenced infraspinatus, anterior deltoid, and posterior deltoid muscles' activity in the shoulder neutral position(p<0.05). In the shoulder $90^{\circ}$ elevation position, anterior deltoid, posterior deltoid muscles' activity was significantly differenced(p<0.05). Hand gripping was found to alter muscle activation. The hand grip task activated the infraspinatus muscle in the neutral position and inhibited the deltoid muscle in the $90^{\circ}$ elevation position. This finding may prove useful for the development preventative measures and rehabilitation strategies for shoulder injuries.

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

Dental Hygienists Work on the Impact of Factors Associated with Musculoskeletal Pain (치과위생사 작업과 관련된 근골격계 통증의 영향요인)

  • Kim, Min A;Seo, Hwa Jeong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.558-565
    • /
    • 2012
  • The purpose of this study was to work related musculoskeletal disorders are a major. Occupational disease of the dental care profession is no exception. The survey was self-reported questionars of 300 dental hygienists that 268 dental hygienists reply to self-reported survey. This study results are as follows: Subjects of research analyzing the degree of physical musculoskeletal disorders pain, shoulder 90.3%, neck 89.2%, leg 83.6%, 81.7% back, hand/wrist/fingers 75.7%, arm/elbow, according to 52.8%. Therefore the work province of the research object people the musculoskeletal disorders appeared different. Generally characteristic was taller dental hygienists lower back pain and were out of less weight, study subjects had neck and arm pain. 29~33 year-old age the shoulder, over the age of 34 the arm/elbow to be high (p<0.05). Working environment to become a career, the more hand/wrist/fingers and the pain increased (p<0.05). The neck, shoulders (p<0.05), arm (p<0.01), waist high in the 3~4 years experience. And leg/foot was in the 1~2 years experience. This increase in working hours had increased pain in the neck but the hand/wrist/finger pain in the small hours of experience in the high pain(p<0.01). Conclusion of the musculoskeletal disorders of the dental hygienists often than the average for this risk is recognized. When it occurs early in treatment can be simple, but time is left to revert to normal when you do not already. Therefore, maintaining proper posture and dental hygienists, pain or fatigue appeared to accumulate immediately treated continued efforts are needed.