• Title/Summary/Keyword: Arm Movement

Search Result 365, Processing Time 0.04 seconds

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm (C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구)

  • Yoo, In Woung;Chung, Jea Yeon;Lee, Kwan Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF

Pattern classification of EMG signals by the syntactic analysis (구문론적 해석에 의한 근전도 신호의 패턴 분류)

  • 왕문성;박상희;정태윤;변윤식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.699-701
    • /
    • 1987
  • This paper deals With the EMG signal processing to apply the EMG signal to the Prosthetic arm. The EMG signals are generated by the voluntary contractions of the subject's musculature and is coded into binary words by the pulse width modulation. Command strings or sentences are constructed by concatenating several words, and are syntactically described by a context free grammar in Chomsky normal form and is tried to classify the movement pattern by the CYK algorithm.

  • PDF

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF

Parameter Analysis of Muscle Models for Arm Movement (팔 근육운동의 파라미터 분석)

  • Kim, Lae-Kyeom;Tak, Tae-Oh
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.155-161
    • /
    • 2008
  • Muscle force prediction in forward dynamic analysis of human motion depends many muscle parameters associated with muscle actuation. This research studies the effects of various parameters of Hill type muscle model using the simple hand raising motion. Motion analysis is carried out using motion capture system, and each muscle force is recorded for comparison with muscle model generated muscle force. Using Hill type muscle model, muscle force for generating the same hand rasing motion was setup adjusting 5 activation parameters. The test showed the importance of activation parameters on the accurate generation of muscle force.

  • PDF

Development of on-line inverse kinematic algorithm and its experimental implementation (온라인 좌표 역변환 알고리듬의 개발과 이의 실험적 수행)

  • 오준호;박서욱;이두현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.16-20
    • /
    • 1988
  • This paper presents a new algorithm for solving the inverse kinematics in real-time applications. The end-tip movement of each link can be resolved into the basic resolution unit, .DELTA.l, which depends on link length, reduction ratio and resolution of the incremental encoder attached to the joint. When x- and y-axis projection of the end-tip movement are expressed in .DELTA.l unit, projectional increments .DELTA.x and .DELTA.y become -1, 0 or I by truncation. By using the incremental computation with these ternary value and some simple logic rules, a coordinate transformation can be realized. Through this approach, it should be noted that the floating-point arithmetic and the manipulation of trigonometric functions are completely eliminated. This paper demonstrates the proposed method in a parallelogram linkage type, two-link arm.

  • PDF

A study on the robot motion analysis by the ROBOT MODAPTS techhique (ROBOT MODAPTS기법에 의한 로보트의 동작분석에 관한 연구)

  • 권규식;이순요
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.15-21
    • /
    • 1992
  • This paper presents the ROBOT MODAPTS(Modular Arrangement of Predetermi- ned Time Standards) technique which can be applied to the robot motion analysis. Robot motions are easily divided into several movement activities and terminal activi- ties by means of the ROBOT MODAPTS technique Each link of robot arm is numbered such that finger is 1, hand is 2, elbow is 3, and so on. The robot motion time of each link is counted by multipling its given number to some time values observed at the finger movement. We can easily estimate robot teaching task time with this technique. This technique can be applied efficiently to establishing an adaptable robot motion ergonomically.

  • PDF

Type of tooth movement during en masse retraction of the maxillary anterior teeth using labial versus lingual biocreative therapy in adults: A randomized clinical trial

  • Sadek, Mais M.;Sabet, Noha E.;Hassan, Islam T.
    • The korean journal of orthodontics
    • /
    • v.49 no.6
    • /
    • pp.381-392
    • /
    • 2019
  • Objective: The objective of this two-arm parallel trial was to compare the type of tooth movement during en masse retraction of the maxillary anterior teeth using labial versus lingual biocreative therapy. Methods: Twenty-eight subjects were randomized in a 1 : 1 ratio to either the labial or lingual group. En masse anterior retraction was performed using labial biocreative therapy in group A and lingual biocreative therapy in group B. Cone beam computed tomography scans were taken before and after retraction and the primary outcome was the type of tooth movement during anterior retraction. Data were analyzed using paired t-tests for comparisons within each group and independent-sample t-test for comparison of the mean treatment changes between the two groups. Results: Significant differences were found between the two groups in relation to the type of tooth movement (labiolingual inclination of the central incisor; mean difference, $5.85{\pm}1.85^{\circ}$). The canine showed significant distal tipping in the lingual group (mean difference, $6.98{\pm}1.25^{\circ}$). The canine was significantly more intruded in the lingual group (mean difference, $1.67{\pm}0.49mm$). Good anchorage control and significant soft tissue changes occurred in both groups. No serious adverse effects were detected. Conclusions: With a 10-mm retraction hook, the labial biocreative technique with the reverse curve overlay provided anterior retraction with good torque control, while in the lingual group, anterior retraction occurred with controlled tipping movement with significant distal tipping and intrusion of the canine (trial registration: The trial was registered at ClinicalTrials.gov [NCT03239275]).

Anti-Stress Effects of Ginsenoside Rg3-Standardized Ginseng Extract in Restraint Stressed Animals

  • Kim, Chung-Soo;Jo, Young-Jun;Park, Se-Ho;Kim, Hae-Jung;Han, Jin-Yi;Hong, Jin-Tae;Cheong, Jae-Hoon;Oh, Ki-Wan
    • Biomolecules & Therapeutics
    • /
    • v.18 no.2
    • /
    • pp.219-225
    • /
    • 2010
  • We tested whether ginsenosides $Rg_3$-standardized ginseng extract (RGE) has anti-stress effects in restraint-stressed animals. RGE increased time spent in the open arms and open arm entries in the elevated plus-maze test. In addition, RGE blocked the reduction of center zone distance and stereotypes behaviors in the open-field test. RGE also increased head dips in stressed mice, indicating anxiolytic-like effects. Stress decreased movement distance and duration, burrowing, and rearing frequency but increased face washing and grooming. RGE significantly reversed burrowing and rearing activity in stressed mice. In addition, we measured sleep architecture in restraint stressed rats using EEG recorder. Stress increased rapid eye movement (REM) sleep, but total sleep and non-rapid eye movement (NREM) sleep were not changed. RGE did not affect sleep architecture in stressed rats. These behavioral experiments suggest that RGE has anti-stress effects in restraint-stressed animal models.

Analysis of Scapulohumeral Rhythm in Scapular Plane by Digital Fluoroscopy System (Digital Fluoroscopy System을 이용한 견갑면에서 일어나는 견갑상완 리듬 분석)

  • Kim Jae-Hun;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.92-105
    • /
    • 2002
  • This research described dynamic scapulohumeral rhythm though the measurement of inter relationship between humorous and scapular movement during elevation of the arm in the scapular plane. In the previous studies static plane film X-ray has usually been used, but the limitation of such method was that it did not show the real· movement. In this study, we investigated real movement of humorous and scapular bones by Digital fluoroscopy system. 1. In resting position, humorous was taken to lie at the average $5.97^{\circ}$ in abduction, and scapular at the average $3.66^{\circ}$ in internal rotation. 2. At the maximal abduction, humorous was abducted to the average of 181.25", and scapular was rotated externally to $51.43^{\circ}$. 3. This research has shown that there is a variety of scapulohumeral rhythm from resting position to $60^{\circ}$ abduction in elevation of humorous. This case study demonstrated that the ratio n of scapulohumeral rhythm is 3.46 to 1, but there was individual difference.

  • PDF