• Title/Summary/Keyword: Argon Discharge

검색결과 124건 처리시간 0.024초

대기압 유전체배리어방전의 발광특성 (Optical Emission Characteristics of Atmospheric Pressure Dielectric Barrier Discharge)

  • 김진기;김윤기
    • 한국재료학회지
    • /
    • 제25권2호
    • /
    • pp.100-106
    • /
    • 2015
  • Plasma properties of dielectric barrier discharges (DBDs) at atmospheric pressure were measured and characterized using optical emission spectroscopy. Optical emissions were measured from argon, nitrogen, or air discharges generated at 5-9 kV using 20 kHz power supply. Emissions from nitrogen molecules were markedly measured, irrespective of discharge gases. The intensity of emission peaks was increased with applied voltage and electrode gap. The short wavelength peaks (315.9 nm and 337.1 nm) measured at the middle of DBDs were significantly increased with applied voltage. The optical emission from DBDs decreased with the addition of oxygen gas, which was especially significant in argon discharge. Emission from oxygen molecules cannot be measured from air discharge and argon discharge with 4.8% oxygen. The emission intensity at 337.1 nm and 357.7 nm related with nitrogen molecule was sensitively changed with electrode types and discharge voltages. However, the pattern of argon emission spectrum was nearly the same, irrespective of electrode type, oxygen content, and discharge voltage.

The effect of addition of noble gases on negative hydrogen ion production in a dc filament discharge

  • James, B.W.;Curran, N.P.;Hopkins, M.B.;Vender, D.
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.40-45
    • /
    • 1999
  • The effect of the addition of helium, neon, argon and xenon on the production of negative hydrogen ions has been studied in a magnetically confined dc filament discharge. The addition of helium and neon produced effects similar to an equivalent increase in hydrogen pressure. However, the addition of argon and low fractions of xenon produced significant increases in the negative ion density for hydrogen at pressures around 1 mTorr. The addition of argon and xenon, by increasing electron density and decreasing electron temperature, achieved conditions closer to optimum for negative ion production. The largest enhancement of negative hydrogen ion density occurred with the addition of argon; it is suggested that this is due to a resonant energy exchange between excited argon atoms and hydrogen molecules.

  • PDF

저기압하의 아르곤 가스의 RF 글로우 방전특성 (RF Glow Discharge Characteristics of Argon at Low Gas Pressure)

  • 곽동주;김두환;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1382-1384
    • /
    • 1995
  • In order to study the structure of RF glow discharge driven at 13.56MHz in argon, the discharge voltage, current and phase shift between them will be measured over a wide range of discharge parameters(gas pressure between 1mTorr and 50mTorr with discharge power between 20mW and 200W). In this paper, the dc glow discharge characteristics and plasma parameters of both FTS and CPMS systems are studied experimentally. It is found that for CPMS system discharge is stablized under wider ranges of magnetic field and pressure than for FTS system. The plasma density and electron temperature of the plasma for these two systems are in the range of $10^{10}{\sim}7{\times}10^{11}[cm^{-3}]$ and $3.5{\sim}6.5$[eV], respectively.

  • PDF

상압 저온 플라즈마 전처리한 폴리아미드계 직물의 색농도 (Color Depth of Polyamide Fabrics Pretreated with Low-Temperature Plasma under Atmospheric Pressure)

  • 이문철
    • 한국염색가공학회지
    • /
    • 제5권2호
    • /
    • pp.134-138
    • /
    • 1993
  • Wool, silk and nylon 6 fabrics were treated with low-temperature plasma under atmospheric pressure of acetone/argon or helium/argon for 30 and 180 sec, and then dyed with leveling type acid dye, C.I. Acid Red 18 and milling type acid dye, C.I. Acid Blue 83. In spite of short time of the plasma treatment for thirty seconds, the color depth of wool fabrics was increased remarkably with both of the plasma gases, aceton/argon or helium/argon and with the kinds of dyes i.e., levelin type or milling type. But the atmosperic low-temperature plasmas did not increase the depth of silk and nylon 6 fabrics dyed with both of the acid dyes regardless of the teated time and plasma gases. It seems that low-temperature plasma by atmospheric-pressure discharge is effective for improvement of dyeing of wools as is the same way with the low-temperature plasma by glow discharge. The kinds of plasma gases and treated time did not influnce the depth of wool fabric pretreted with the atmosperic low-temperature plasmas.

  • PDF

저압 방전등 교류 접등 특성의 이론적 예측 (Theoretical Prediction of AC Characteristics of Low Pressure Lamps)

  • 지철근;장우진;여인선;이진우
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.470-476
    • /
    • 1989
  • In order to develop a mathematical model which can predict the operating voltage and current of a discharge lamp, the properties and the physical phenomena of a low pressure gas discharge are investigated. Fluorescent lamp which uses a low pressure mercury-argon gas discharge is used in the model development. In a low pressure mercur-argon gas discharge, the continuity equation for each excited atom and electron, and the electron energy balance equation can predict the physical quantities of discharge. By coupling these equations and the circuit equation, the electrical characteristics of the discharge lamp can be predicted. To verify the validity of the suggested model, we calculated the voltage and current of a fluorescent lamp operating with inductor ballast for source frequency of 5KHz, 8KHz, 10KHz, and 13KHz. The results show good agreements in wave forms between the measured voltage and current, and the difference between the measured and calculated one is less than 5%.

  • PDF

아르곤 직류방전의 충돌쉬스 구조해석 (Analysis of Collisional Sheath in an Argon dc Discharge)

  • 최영욱;이해준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1647-1649
    • /
    • 2003
  • The electric fields of the sheath region in an argon do discharge were measured using a laser optogalvanic spectroscopy in a pressure range from 0.88 to 10 Torr, where collisions are significant in the sheath region. The sheath width is estimated as the position where the electric field becomes zero, and the pressure dependence of the measured sheath width was obtained to be $(pressure)^{-1/3}$. The measured electric fields agree well with one-dimensional simulation results but are slightly different from collisional sheath theory in the mobility limited region.

  • PDF

글로우방전을 이용한 가스크로마토그라프 검출기의 개발 (Glow Discharge as Detector for Gas Chromatography)

  • 김효진;박일영;장성기;김박광;박만기
    • 약학회지
    • /
    • 제37권1호
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF

Study on the Effects of Ultrasonic Wave for the Effective Hydrogen Generation by Electrical Discharge Plasma Process

  • Park Jae-Youn;Cong Nghi-Vu;Han Sang-Bo;Kim Jong-Seok;Park Sang-Hyun;Lee Hyun-Woo;Lee Su-Jung
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.591-598
    • /
    • 2006
  • The research was tried to investigate the hydrogen generation from water by the pulsed power plasma process. Hydrogen was generated by way of the electrical pulse power discharge process with the ultrasonic wave. The yield on the hydrogen generation was also studied with and without operating the ultrasonic generator, in which the applied high voltage was varied from 10 kV to 15 kV. Nitrogen and argon gases were used as working gases. As the results, the generation yield using the pure nitrogen gas is better than argon and mixed gases such as argon and nitrogen. Hydrogen concentration are significantly increased when the ultrasonic generator was operated with the electrical discharge simultaneously. It is increased with increasing the applied ultrasonic level as well.

A simple analysis on the abnormal behavior of the argon metastable density in an inductively coupled Ar plasma

  • 박민;유신재;김정형;성대진;신용현;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.438-438
    • /
    • 2010
  • The abnormal behavior of the argon metastable density during the E-H mode transition in argon ICP discharge was investigated. Lots of investigations including global models expected that during and after the mode transition of ICP discharge, the density of metastable increases with applied rf power (i.e. electron density). However, recent direct measurement of metastable density revealed that the metastable density of argon decreases with the applied power during and after the mode transition. This result may not be explained by the previous global model which is based on the assumption of the Maxwellian electron energy distribution function (EEDF). In this paper, to explain this abnormal behavior with simple manners, a simple global model taking account of the effect of the non-Maxwellian EEDFs incorporating into a set of coupled rate equations is proposed. The result showed that the calculated metastable density taking account of non-Maxwellian EEDF and its evolution during the transition has an abnormal behavior with electron density and is in good agreement with the previous measurement results, indicating the close coupling of electron kinetics and the behavior of metastable density. The proposed simple model is expected to provide qualitative kinetic insight to understand the behavior of the metastable density in various plasma discharges which typically exhibit non-Maxwellian distribution.

  • PDF

저압 수은-아르곤 혼합기체 방전의 주파수에 따른 전압, 전류 변화의 이론적 해석 (A Theoretical Analysis of Voltage and Current in Low Pressure Mercury-Argon Mixture Gas Discharge with Frequency Variation)

  • 이진우
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.23-27
    • /
    • 2005
  • 저압 수은-아르곤 혼합기체 방전을 이용하는 형광램프는 일정전력을 소비하는 경우, 전원주파수 1(kHz)부근에서 전류는 최대 값을 램프전압은 최소 값을 갖는 현상을 나타낸다. 본 논문에서는 원자레벨의 방전 모델 식을 만들어 입자밀도와 전자온도의 변화를 수치해석을 이용하여 계산하고, 이를 이용하여 전원주파수에 따라 형광램프의 전류와 램프전압이 변화하는 현상을 이론적으로 설명하였다.