Evaluation of Operation Characteristics with Aeration Time in Intermittent Aeration Membrane Bioreactor (간헐포기 MBR공정에서 포기시간에 따른 운전특성 평가)

  • Lim, Bong-Su;Choi, Bong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 2005
  • This study was conducted to evaluate the operation characteristics with aeration time in intermittent aeration membrane bioreactor. The BOD removal efficiency rate of this process was over than 97% regardless of aeration on/off time. To get over than 82% of nitrogen removal efficiency rate, aeration off time needs more than 70 minutes in reactor. Specific denitrfication rate was 2.68 mg $NO_3-N/gMv/hr$ in 40/80 min aeration on/off time, was 2.6 times more than 60/60 min, and 1.4 times more than 50/70 min in 6,300 mg/L of MLSS concentration. Specific nitrification rate was 1.96 mg $NH_4-N/gMv/hr$ in 50/70 min, was 1.4 times more than 40/80 min, but it was effectded little upon nitrification. Microbial activity was effected little according to aeration on/off time, oxygen demend was reduced according to aeration off time increased and microbial concentration increased. The longer aeration off time become, the higher Extraceller Pollymeric Substance (EPS), 50/70 min and 40/80 min in aeration on/off time was increased 1.6 times and 2.7 times, respectively more than 60/60 min because of increase of operation pressure.