• Title/Summary/Keyword: Area source

Search Result 3,577, Processing Time 0.031 seconds

A Study for the Selection Method of Control Area of Nonpoint Pollution Source (비점오염원 관리지역의 선정 기법에 관한 연구)

  • Park, Sanghyun;Jeong, Woohyeok;Yi, Sangjin;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Air Quality Impact Analysis of Point and Area Sources (점오염원과 면오염원의 대기환경영향 분석)

  • 김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.168-173
    • /
    • 1993
  • Air quality impacts of point and area sources were analyzed by using ISCST2 with wind speed and stability class combinations of SCREEN. Stack height was important in determining the impact of point sources. With the stack height reduced to 21m from 75m, the concentration in the vicinity increased several times in spite of decreasing the emission rate by half. When the emission rates were same, concentrations from an area source of 10m release height were slightly lower than those from a point source of 21m stack height at the plume centerline. Bur the area source resulted in larger area of high concentration. Concentration from the point source was high in neutral to slightly unstable conditions with strong winds in a short distance, and in stable conditions with weak winds in a long distance. Concentration from the area source decreased with distance from the source, and was high in stable conditions with weak winds.

  • PDF

Characteristics of Source and Concentration of VOCs in Daegu (대구지역 대기 중 VOCs 농도 및 발생원 특성)

  • Gu Min-Jung;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.543-553
    • /
    • 2005
  • In recent days, photochemical smog due to the rapid industry development and vehicle increasement has become a critical pollutant in the metropolitan area and the number of ozone alarm signal has increased every year. This research was performed to evaluate VOCs emission source characteristics and concentration of VOCs in Daegu. The site average concentration was observed in the following order: industrial area > commercial area > residential area. Most of the VOCs species except toluene showed variations with higher concentration during nighttime, and lower concentration during the daytime. The major VOCs of stationary emission source were BTEX(benzene, toluene, ethylbenzene. xylene) and methylene chloride, trichloroethene and styrene. Also, those of automobile exhaust were toluene and benzene. Also, the major VOCs concentration emited by the vehicle fuel was observed in the following order: gasoline > light oil > liquefied petroleum gas (L.P.G). Correlation coefficients values were estimated between major VOCs such as toluene, ethylbenzene, m,p-xylene, o-xylene. Results showed that correlation coefficient values were significant magnitude above 0.76. Also, there showed highly significant correlations among ethyl benzene, m,p-xylene, and o-xylene concentration(Pearson correlation coefficients, r=0.868-0.982). Calculated correlation coefficients among commercial area,industrial area and residential area were 0.934-0.981, they showed high correlation. There showed highly correlation between stationary emission source and industrial area, compared with commercial area and residential area. Also, calculated correlation coefficients among commercial area, industrial area, residential area and automobile exhaust were 0.732, 0.725, 0.777, respectively.

A study on the Development of TCM Urban and Rural mode for Environmental Impact Assessment (환경영향평가를 위한 도시형과 교외형 TCM 개발에 관한 연구)

  • Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.1
    • /
    • pp.63-70
    • /
    • 1998
  • TCM has been used for many environmental impact assessments in Korea. But there was reported that an error was found in area source calculation of original TCM and modified. In this study, TUM(TCM-urban mode) and TRM(TCM-rural mode) were developed for urban and rural area by modification of original TCM. McElroy-Pooler dispersion parameter was used for area and point source in TUM, Pasquill-Gifford parameter was used for area and point source in TRM. And Irwin's vertical wind speed profile exponents were used for TUM and TRM. Then predicted value by TUM, TRM and a value from the same area and point data by CDM2, ISCLT3 were compared. And it was found that predicted value from point source by TUM, TRM was very similar to a value by CDM2, ISCLT3, and predicted value from area source by TRM was similar to a value by CDM2, ISCLT3. But predicted value from area: source by TUM was an half lower than a value by CDM2, ISCLT3.

  • PDF

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Stormwater Runoff Characteristics of Non-point Source Pollutants according to Landuse of Urban Area (도시지역 토지이용에 따른 비점원 오염물질 유출특성)

  • Jeong, Dong-Hwan;Shin, Dongseok;Rhew, Doughee;Jung, Dongil
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.525-532
    • /
    • 2007
  • In order to establish and implement the total maximum daily load (TMDL) management plan in Korea, it is necessary to set the source units and calculate discharge loads for non-point source pollutants such as BOD, COD, SS, TN and TP. This study analysed the corelation between stormwater runoff characteristics and event mean concentrations (EMCs) of non-point source pollutants. As the result of the corelation analysis, we knew that all the antecedent dry days (ADD) and the rainfall correlated lowly with non-point source pollutants in the urban areas such as resident area, industrial area, business area, road area and parking area. Therefore, it is necessary to get all samples from stormwater starting point to stormwater ending point and standardize the sampling method of stormwater in order to obtain more accurate EMCs for landuse.

Behavior-Structure-Evolution Evaluation Model(BSEM) for Open Source Software Service (공개소프트웨어 서비스 평가모델(BSEM)에 관한 개념적 연구)

  • Lee, Seung-Chang;Park, Hoon-Sung;Suh, Eung-Kyo
    • Journal of Distribution Science
    • /
    • v.13 no.1
    • /
    • pp.57-70
    • /
    • 2015
  • Purpose - Open source software has high utilization in most of the server market. The utilization of open source software is a global trend. Particularly, Internet infrastructure and platform software open source software development has increased rapidly. Since 2003, the Korean government has published open source software promotion policies and a supply promotion policy. The dynamism of the open source software market, the lack of relevant expertise, and the market transformation due to reasons such as changes in the relevant technology occur slowly in relation to adoption. Therefore, this study proposes an assessment model of services provided in an open source software service company. In this study, the service level of open source software companies is classified into an enterprise-level assessment area, the service level assessment area, and service area. The assessment model is developed from an on-site driven evaluation index and proposed evaluation framework; the evaluation procedures and evaluation methods are used to achieve the research objective, involving an impartial evaluation model implemented after pilot testing and validation. Research Design, data, and methodology - This study adopted an iteration development model to accommodate various requirements, and presented and validated the assessment model to address the situation of the open source software service company. Phase 1 - Theoretical background and literature review Phase 2 - Research on an evaluation index based on the open source software service company Phase 3 - Index improvement through expert validation Phase 4 - Finalizing an evaluation model reflecting additional requirements Based on the open source software adoption case study and latest technology trends, we developed an open source software service concept definition and classification of public service activities for open source software service companies. We also presented open source software service company service level measures by developing a service level factor analysis assessment. The Behavior-Structure-Evolution Evaluation Model (BSEM) proposed in this study consisted of a rating methodology for calculating the level that can be granted through the assessment and evaluation of an enterprise-level data model. An open source software service company's service comprises the service area and service domain, while the technology acceptance model comprises the service area, technical domain, technical sub-domain, and open source software name. Finally, the evaluation index comprises the evaluation group, category, and items. Results - Utilization of an open source software service level evaluation model For the development of an open source software service level evaluation model, common service providers need to standardize the quality of the service, so that surveys and expert workshops performed in open source software service companies can establish the evaluation criteria according to their qualitative differences. Conclusion - Based on this evaluation model's systematic evaluation process and monitoring, an open source software service adoption company can acquire reliable information for open source software adoption. Inducing the growth of open source software service companies will facilitate the development of the open source software industry.

Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics (전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.

The application of shallow seismic reflection method for Chechon limestone area (제천 석회석 지역의 탄성파 반사법의 적용)

  • Suh, Beak-Soo;Lee, Duk-Jae
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.303-309
    • /
    • 2000
  • Seismic reflection method is applied to detect shallow location of limestone in Chechon area. The data using hammer source is compared with that of weight drop. Small size hammer and weight-drop are used as energy source and 100Hz geophones are used for data aquisition. Data processing is conducted utilizing the available processing technique of "Geobit", which is seismic data processing software developed by KIGAM. The result of above data processing, the velocity of topsoil layer is 1,250m/sec. The velocity of this area is higher than other area because loading trucks pass this area and make this layer compact. And in limestone area, hammer is proposed to energy source instead of weight drop because the energy propagates the layer very well.

  • PDF

Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area (수원지역 입자상 오염물질의 오염원 기여도의 추정)

  • 이태정;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF