• 제목/요약/키워드: Area Ratio

검색결과 8,039건 처리시간 0.035초

압밀특성에 관한 연구 (I) (선행하중이 압밀특성에 주는 영향) (A Study on the Characteristics of Consolidation of Soils (I) (The Influence of Pre-consolidation Load of Soils on Consolidation Characteristics))

  • 류능환;강예묵
    • 한국농공학회지
    • /
    • 제18권4호
    • /
    • pp.4242-4250
    • /
    • 1976
  • The determination of the pre-consolidation load known to have a great effect on the consolidation characteristics of the soil have been researched and discussed in detail by many other researchers. A study was undertaken to investigate and compare the effect of pre-consolidation loads on the coefficient of permeability and the consolidation characterisics of soil through the consolidation test on the three types of soil samples. The results of this study are follows; 1. Large compression index is dependent on initial void ratio of the sample being used and the pressure-void ratio curve shows a curved linear relationship in over-consolidated area but a linear relationship in normally consolidated area.2. Settlement-time curve is S-shaped where the pressure is larger than pre-consolidation load and regardless of over-burden pressure, it is a similar straight line respectively in the secondary consolidation area. 3. Primary consolidation ratio of the sample increases almost linearly with the increase of over-burden pressure but the coefficient of volume compressibility decreases linearly with the increase of it. 4. Time factor of a certain degree of consolidation increases with over-burden pressure but the coefficient of consolidation decreases with it in over-consolidated area. There is a linear relationship between them in normally consolidated area. 5. The void ratio of completion point of primary consolidation decreases linearly with over-burden pressure. 6. The coefficient of permeability of sample decreases linearly with over-burden pressure in normally consolidated area, also it increases linearly with increment of the void ratio of the sample.

  • PDF

다공튜브 오리피스 면적비 변화가 출구유동에 미치는 영향 (Effect of the Orifice Area Ratio on the Exit Flow of a Multi-Perforated Tube)

  • 이상규;이지근
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.317-323
    • /
    • 2013
  • A multi-perforated tube indicates the existence of multiple holes of various shapes on the surface of a long cylinder-type or rectangular tube, and a hole installed on the surface is called an orifice, as it is relatively small in size, compared with the surface area of the tube. In this study, the flow characteristics of a circular multi-perforated tube with many orifices on the surface were investigated experimentally and numerically. The volume flowrate issuing from each orifice, discharge angle, effective flow area ratio, and the flow fields around the orifices were measured and visualized, with the variation of the orifice area ratio, at the same blockage ratio. The volume flowrate distributions along the flow direction of the multi-perforated tube tends to be more uniform, as larger orifices were positioned at the inlet side of the multi-perforated tube, compared with no orifice area change along the flow direction.

슬릿버너에서 형상변화가 연소특성 및 배기배출물에 미치는 영향 (The study of combustion characteristics and emissions with the variation of design factor on slit gas burner)

  • 김태우;조승완;장영준;전충환
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.314-319
    • /
    • 2005
  • In this study, the combustion characteristics were investigated with the variation of design factors on multiple slit gas burner. The design factors consist of slit height, width, spacing, and inner length. The combustion characteristics were made analysis of the CO emission and NOx emission by using CO analyzer and NOx analyzer. The lower perimeter to area and the narrow spacing extends the lift-flame limit. The CO emission increases with the increasing perimeter to area ratio at the same condition. The NOx emission is found to be less significant with the port perimeter to area ratio. The flame interference might highly depend on the spacing and port perimeter to area ratio, and it also affects the burner performance.

  • PDF

경남지역 고등학교시설의 생태환경 실태에 관한 사례 연구 (A Case Study on the Actual Conditions of Ecological Environment of the High School Facilities in Gyeongnam Area)

  • 양금석
    • 한국농촌건축학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-64
    • /
    • 2010
  • This study is to clarify the actual conditions of high school of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of the study, First, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment friendly architecture and certification high school, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual condition of ecological environment elements per non-certification high school by collecting actual data of certification schools environment friendly architecture were analyzed and the results are as the follows. The average of ecological area ratio was 17.8 percent in case of non-certification school facilities it was analyzed that the natural based green area ratio was 17.5 percent, continuous green axis length ratio was 19.0 percent and roof green garden area ratio was 0 percent.

국내 뮤지엄 면적구성 요인에 관한 연구 - 각 영역사이의 면적구성 프로그램 개발을 위한 국내 뮤지엄의 전수조사를 중심으로 - (A Study on the Causes for Space Program of Korea's Museum - With Reference to the Whole Survey of Korea's Museum in Conjunction with Development of Domain-Specific Configuration of Floor Area -)

  • 홍제형;문정묵
    • 한국실내디자인학회논문집
    • /
    • 제21권2호
    • /
    • pp.14-22
    • /
    • 2012
  • In regards to museum planning of Korea, it is mainly depending on overseas cases and relevant domestic books without systematic guideline on the space programme in a museum. Therefore, it is urgently required to establish systematic index as it is incapable of proposing detailed analysis and index in accordance with each element. As various problems occurred due to above reason, total floor area of museum was divided by the area of exhibition section, storage section, research section, and public & other area and its ratio was calculated for statistics targeting 614 museums built after 1990's when many public museums were built with the settlement of local self-governing system and the type of museums was diversified. It was again classified into 4 elements of period, region, scale, and type and then the influence of each element on each section of museum was understood through integrated analysis. First, looking into the space programme in regards to total floor area, the floor area ratio of exhibition section, storage section, and research section decreased and the floor area ratio of public & other area increased with the increase in total floor area. It was because not only rest area but also a space to enjoy various cultures, gaining new experience, and accumulate knowledge is located in public & other area. Second, it was revealed that the ratio of exhibition section and storage section has been decreasing since 1990's and ratio of research section and public & other area has been increasing as they can play various roles such as the education and convenience to satisfy cultural desires of visitor in accordance with current trend. Third, it was proved that floor area ratio of exhibition section is lower than storage section in museums located in highly urbanized region. In addition to this, it was revealed that the floor area ratio of research section is in proportion to the population density. As a result of study, significant relation was displayed in scale, era, and region among 4 elements thus it could be utilized as reference for the space programme of domestic museum planning in the future.

  • PDF

건물 외피 창호면적 변화에 따른 에너지 소비량에 관한 연구 (Study on the Analysis of Energy Consumption Corresponding Window Area Ratio)

  • 하대웅;박경순;손원득
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.857-862
    • /
    • 2008
  • Window is the most demanding design component in the building design. Recently, window area in the building surface has been increased significantly in the office building. As window area increased significantly, however, the thermal load has been increased significantly due to lack of thermal performance of the outside wall. In this paper, we discussed the energy consumption of the buildings according to window area ratio. Two types of building for energy consumption analysis were made by Designbuilder v.1.4 and Energyplus v.2.0. Window area ratio was five different types ($30%{\sim}70%$) in each building. As a result, the cooling energy consumption has been decreased as window area decreased in each building. Whereas the heating energy consumption has been increased window area decreased.

  • PDF

종합병원의 G/N비 산정에 관한 건축계획적 연구 (A Study on the Architectural Planning for Measurement of Gross-to-Net Ratio in General Hospital)

  • 조준영;김은석;양내원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제16권4호
    • /
    • pp.33-40
    • /
    • 2010
  • Gross-to-net ratio is the important factor determining size of the building. However it was determined as the empirical method without the exact basis in the existing planning. This paper proposes more accurate methods for determining the gross-to-net ratio of architectural planning in general hospital. This paper analyzes the difference of gross-to-net ratio according to the various conditions and presents the elements of influencing on gross-to-net ratio. These elements is evaluated by applying in the typical hospital case. In conclusion, gross-to-net ratio is influenced by the accuracy of the space program, form type of the space and correspondence potential about the internal variation. In addition, This study has proved that empirical approach is a standard of minimum area.

Al5083-O 알루미늄합금의 보호가스 혼합비율 및 입열량에 따른 GMA용접 특성에 관한 연구 (A Study on the GMA Welding Characteristics of Al5083-O Aluminum Alloy According to the Shield Gas Mixing Ratio and Heat Input)

  • 정재강;양훈승;이동길
    • Journal of Welding and Joining
    • /
    • 제20권2호
    • /
    • pp.65-70
    • /
    • 2002
  • This study was to evaluate GMA welding characteristics of the A15083-O aluminum alloy according to the shield gas mixing ratio and heat input change. The GMA welding of the base metal was carried out with flour different shield gas mixing ratios(Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%). Regarding the if1uence on the bead shape of the shield gas mixing ratio and heat input, the bead width was greatest in Ar100%+He0% mixture. But the penetration depth and area were greatest in Ar33%+He67% mixture considering that the lower Ax gas ratio, the higher bead depth and area. Also, dilution was also best in the shield gas mixing ratio. The size and number of deflects were least in Ar33%+He67% mixture. Higher He gas ratio resulted in less deflects detected by the radiographic inspection.

경골목조주택의 벽체-바닥체 못결합부의 감쇠비에 관한 연구 (Studies on Damping Ratio of Nailed Joint Connecting Wall to Floor in Light Frame House)

  • 김광모;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권3호
    • /
    • pp.65-71
    • /
    • 1996
  • In the design of wood structures, the consideration of the dynamic load effect has been increased. Generally, damping ratio is presented as the method of considering dynamic load effect. So, the relationship between joint type and damping ratio was investigated. It has been known that the joint extremely damp the dynamic load in wood structures. Static test was performed to determine the effects of nail size and friction area on joint strength and stiffness. Joint strength and stiffness were increased with nail size. However, the static properties of joint was not affected by friction area. Cyclic test was performed to determine the effects of nail size, friction area and load magnitude on damping ratio, Damping ratio was affected by all factors. Increasing the width of the bottom plate was suggested as the most adequate method to increase the damping ratio without the reduction of the static properties of the structures.

  • PDF

농업용 저수지 수질과 경험적 인자들과의 관계 (The Relationships Between Empirical Factors and Water Quality in Agricultural Reservoirs)

  • 김호섭;최은미;박주현;황하선;김범철;공동수;황순진
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.333-339
    • /
    • 2008
  • This study was carried out to assay the relationships between empirical factors and water quality in 23 agricultural reservoirs. Based on the trophic state index (TSI) deviation analysis, phosphorus in type II and III was the primary limiting factor on algal growth. BOD, COD, TP and chl.a concentration in type III reservoirs showed higher concentration than those of other types, while SS and TN concentration was no noticeable difference among three types. Characteristics of type III reservoirs showed large reservoir surface and drainage area, large surface area to volume (SAV) ratio, small drainage area to reservoir area (DA/RA) ratio, relatively old age, large paddy field and upland field to drainage area ratio (Mean 17.4%) and high generation and discharge loads compared to other types of reservoirs. In type I and II reservoirs, trends of BOD, TN, TP concentration in water column, were similar to those of the discharge load of pollutants. Although type II reservoirs generally showed low phosphorus discharge loads compared to type I reservoirs, TP and chl.a concentration in water column was greater than that of type I. Characteristics of type II reservoirs showed relatively large SAV ratio and old age compared to type I reservoirs and was similar to those of type III including eutrophic reservoirs.