• 제목/요약/키워드: Architectural lighting

검색결과 197건 처리시간 0.03초

조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구 (A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting)

  • 오병길;정민호;원종서;이훈
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

한국·중국·일본의 도시경관조명 현황 및 정책 분석 - 서울, 상하이, 요코하마를 중심으로 - (An Analysis on the Outdoor Lighting Situation and Policies in Korea, China, Japan - focused on Seoul, Shanghai, Yokohama-)

  • 안현태;김정태
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.35-42
    • /
    • 2003
  • It is required impressive expression of urban night environment that makes city as the safe pleasant, convenient place for the economic activity, cultural pleasure and landmarks. This study aims to establish the proper direction to the outdoor lighting in Seoul by analyzing and comparing the lighting situation and policies among Seoul, Shanghai and Yokohama. 1986 Asian Game and 1988 Olympic Game became very important role of activation of outdoor lighting in Korea. Then, outdoor lighting were facilitated in the cultural heritages and bridges along Han river. Millenium Light Plan, Outdoor Lighting Field of Seoul Architectural Award, 2002 Lightscape Local Plan, hosting 2002 World Cup have been good opportunities for the improvement of outdoor lighting in Seoul. In China, outdoor lighting was introduced to the city of Shanghai according to the orders of the president in 1988. Outdoor lighting of Shanghai have created unique lighting with beautiful color and intensive brightness under the direction of city government. Outdoor lighting of Shanghai needs the standard of lighting design and improvement of lighting facilities. Outdoor lighting was introduced to Japan with 1964 Tokyo Olympic games. Urban outdoor lighting plan was carried out in Yokohama in 1986. In Yokohama, outdoor lighting of civilian and public facilities have been harmonized. And the city government of Yokohama established the committee of promotion of outdoor lighting in its government to support and manage the outdoor lighting with corporation of civilian organization. As the result of comparative analysis on Seoul, Shanghai, Yokohama, Seoul Metropolitan Government needs the criteria and incentive system of outdoor lighting.

A Study on Lighting Environmental Evaluation of Senior Welfare Centers Based on biophilia

  • Yang, So Yeon;Lee, Tae Kyung
    • Architectural research
    • /
    • 제22권4호
    • /
    • pp.123-133
    • /
    • 2020
  • Light is an essential environmental element for elderly people to do various activities. At senior welfare centers, healthy indoor lighting is especially necessary because the facilities are used by the elderly to perform their mostly indoor activities. The purpose of this study is to evaluate light environments at senior welfare centers for well-being lighting characteristics. We based the study on the 'Biophilia' theory, a concept related to health from happiness. Thus, this study is mainly based on literary review and survey research. For this, we conducted a location focused field study to identify the current state of the lighting environments at senior welfare centers in Busan, South Korea. First, we constructed structural questionnaire to evaluate lighting environment based on 'Light and Space' biophilia theory. Then, to survey subjective evaluation, the participant of research included total of 122 senior welfare center users. Based on the results of this research, the conclusions are as follows; 1) overall, it seems that the overall result of the light environmental evaluation seems to be high because the evaluated facilities in the case survey in large-scale were recently built elderly welfare centers. 2) most of the healing design elements are focused on the introduction of natural light and psychological influence. The satisfaction with actual natural light is evaluated to be high. Although shadow and reflected light are very important in discrimination and recognition of indoor space and wayfinding, the evaluation of reflected light and shadow was low for the study. 3) items that are related to the functionality of the light were highly evaluated, while the items that are related to the spatiality of the light were rated poorly. This study has its significance when examining the effects of light environments within the welfare center form of the perspective of senior citizens. It can be referenced when reconsidering the recognition of light environment as a major consideration factor to establish a desirable senior welfare center environment.

염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로 (A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space)

  • 이응직
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.

A Study on the Actual Condition of Illumination Environment in Public Libraries in Daegu

  • Seo, Ji-Eun;Kim, Hyun-Ji;Kim, Sung-Hwa;An, Ok-Hee
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2009
  • This study investigated the actual condition focusing on the lighting environment which is a major element in aspect of indoor environment of a public library and assessed user satisfaction. Research results are as follows: Firstly, numbers of lighting fixtures per dimension of a reading room in a public library were inconsistent due to the lack of definite regulations, which was found to have negative effect on night time illuminance. Secondly, it was assessed that illuminance between the day time influenced by natural lighting and in the nighttime without natural lighting has more than 10-fold difference. Therefore, such a condition is judged to be inappropriate for lighting environment of a reading room where users spend a long time studying and thus, it is considered that an appropriate measures should be taken. Thirdly, as the survey result on users' satisfaction with lighting environment was revealed to be lesser than 3 points, lighting plan in consideration of its users should be progressed.

사무소건물의 LED조명기구 방열장치의 성능 분석 연구 - 덕트 내 유량변화 중심으로 - (Performance of heat sinks for LED luminaires in office buildings - Focused on the variation of air flow rate in duct -)

  • 박지우;안병립;김종훈;정학근;장철용;송규동
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.81-86
    • /
    • 2014
  • In recent years, many researchers have considered the building energy consumption reduction accordingly to deal with abnormal climate changes and greenhouse gas reduction. However, the lighting energy use ratio has increased in spite of the development of the high efficiency lighting device. Therefore, the study aims to produce the LED lighting applications for the effective lighting heat removal by using the heat characteristics of LED lighting and analyzing the heat removal effect. In order to increase radiant heat efficiency, the heat pipe and heat sink was attached on PCB as LED lighting applications. Experiment was conducted to verify the temperature and air velocity of inside duct: thermocouples, anemometer. The heat removal effect of LED lighting applications was measured by observing the temperature of the lighting applications and the change of air velocity in duct. The experiment shows that the temperature change in the duct according to air velocity was $0.9{\sim}5.8^{\circ}C$. It is also concluded that heat removal was calculated from 33 to 81W.

축열과 채광조절을 겸한 자연형 태양열 수벽시스템의 집열방식별 성능실험 (Experiment on measures of heat collection for passive solar water wall systems that provide heat storage and natural lighting control)

  • 오영훈;최지은;이철성;윤종호
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.63-69
    • /
    • 2016
  • Purpose: This preliminary study investigated a potential of the water wall systems that provide heat storage and natural lighting control simultaneously. Method: In order for transparency of the water wall to be controlled, the study first proposed two measures: to adjust transparency of the water wall; to control transparency of water wall surface. The performance of two measures then was verified and compared by experiments. In addition, a trade-off between heat collect and heat storage resulting from using additive for adjusting transparency was investigated. Result: The experiment showed that the two measures are similar in performance. The investigation of trade-off relation showed the additive should have the same heat storage as the water to prevent decrease in thermal performance of the water wall. As an economical measure to control transparency of the water wall, this study suggested a measure of secondary heat transfer systems using shading device that first absorbs solar radiation and then transfers heat to the water wall. The experiment show that performance of the proposed measure is similar to controlling transparency of water wall surface. In conclusion, it is expected that the performance of the water wall can be economically maximized by using the proposed mean in terms of heating, cooling and lighting energy saving.

A Case Study on the Role of LED Lighting at the Residential Space

  • Kim, Hye Young
    • International Journal of Advanced Culture Technology
    • /
    • 제4권4호
    • /
    • pp.6-12
    • /
    • 2016
  • Due to the development of technology, the modern people became to require not only more convenient life but also more comfortable and emotional environment, and individually suitable living environment is applied to residents in a residential space. Recently, while the LED lighting was variously attempted in every sector in society, it is needed to express differentiated lighting according to the resident's individual lifestyle in a residential space. In this paper, we analyze the role of LED lighting suitable for the digitalized lifestyle of the modern people through the relevant literature survey and case studies. The following results are obtained in summary of the rapidly changed recent trends of LED lighting. First, LED light replace existing light sources due to the advanced new technology in LED industry, and take the spotlight as a new lighting solution with the development of variable color LED bulb and the control technology by the wired and wireless communications. Second, LED lighting can be structurally applicable to every lighting device because of its compact and lightweight units, can produce abundant light environment by expression of variable colors and moods with the easy coloring and dimming control, can be reborn as emotional lighting design. Third, as recently practices are constantly appeared that integrate LED lights in the interior elements, such as object and furniture, and combine advanced LED lighting technology to new materials, the portion of illumination on the indoor environment is further increased after integrating the LED lighting and interior elements make boundaries of lighting and product architecture become blurred. LED lighting is confirmed that is being changed from the external functionality including material, shape, color, and etc. into the contextual emotion design including the lights expression, variable color, brightness control, making image, and etc. as the light source in current smart lighting era.

야간경관조명이 된 역사적 건축물의 휘도분포 및 주관적 반응 분석 - 남대문, 광화문, 장안문, 팔달문을 중심으로- (An Analysis on the Luminance Distribution and Subjective Responses on Image of Historic Buildings Illuminated by Outdoor Lighting - Focused on the Namdaemun, Kwanghwamun, Changanmun and Paltalmun -)

  • 안현태;정인영;김정태
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.29-36
    • /
    • 2004
  • Designing outdoor lighting on landmarks has been activated in Korea since 2002 World Cup. And outdoor lighting has been important method to create nighttime activities. Especially, historic buildings which are illuminated by outdoor lighting expresses cultural beauty of the heritages in the region. Therefore, this study aims to analyze the outdoor lighting effect of historic buildings with particular reference to four historic buildings - Namdaemun, Kwanghwamun, Changanmun and Paltalmun. For the purpose, luminance of outdoor lighting are measured. Outdoor lighting of the historic buildings were mainly illuminated by the floodlights. In addition, up-lighting and accent lighting were used for expressing the bracket structure. Basements and rooflines are emphasized by floodlighting, and they represented the night image of historical buildings. For the subjective evaluation on the outdoor lighting of historic buildings, outdoor lighting images of four historic buildings - Namdaemun, Kwanghwamun, Changanmun and Paltalmun were photographed. Questionnaire surveys were conducted by hundred and twenty university students of architectural department And collected papers were statistically analyzed by SPSS. Factors that shows outdoor lighting images of historical buildings are as follows; atmosphere, clearness, intimacy, modelling. On the question of general impression of outdoor lighting, Kwanghwamun has got the most satisfactory responses and the next is Changanmun and Namdaemun, Paltalmun. Major variables which related to the 'general impression' of outdoor lighting for historic buildings have been 'dignity', 'match', 'elegance', 'beauty' in the order.

빛환경 및 냉난방환경 기반 광선반 성능평가 연구 (Performance Evaluation of Light-Shelf based on Light Enviorment and Air Conditioner Enviorment)

  • 전강민;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.47-55
    • /
    • 2016
  • Purpose: As the energy consumed by buildings increases, there is a growing need for studies and technology development to address this issue. One of the solutions to excessive energy use by buildings is the light-shelf, which is a natural lighting system enabling efficient reduction in light energy, and research in this area has been intensive. However, most of the studies about the light-shelf are limited to the light environment, and thus the application of their findings to an actual environment in the form of a design may be problematic. Therefore, the purpose of the present study is to provide fundamental data for light-shelf design by carrying out a light-shelf performance evaluation on the basis of the light environment and the heating and cooling environment. Method: In the present study, a testbed was established to conduct a light-shelf performance evaluation by measuring the electric power consumption of lighting and heating and cooling devices depending on the existence of a light-shelf and its angle. Result: The findings of the present study are as follows: 1) With respect to the uniformity of the indoor light environment amenity, the optimum angle of a light-shelf was found to be $30^{\circ}$ for the summer solstice and the winter solstice. 2) With respect to the reduction of electric power consumption by indoor lighting devices, the optimum light-shelf angle at the summer solstice is $30^{\circ}$, at which time electric power consumption may be reduced by 10.2% in comparison with when no light-shelf is applied. However, at the winter solstice, a light-shelf may increase the energy consumption for lighting in comparison with when no light-shelf is applied, and this should be taken into account in the design of a light-shelf. 3) In terms of reducing the electric power consumption of heating and cooling devices, the optimum angle of a light-shelf was found to be $30^{\circ}$ for the summer solstice, while a light-shelf is inappropriate for the winter solstice since a light-shelf creates shade and thus increases the heating energy consumption. 4) To summarize the findings above, the optimum angle of a light-shelf is $30^{\circ}$ for the summer solstice, but the installation of a light-shelf may in some circumstances increase the energy consumed by lighting devices as well as by heating and cooling devices. Therefore, more studies and technology development may need to be performed to solve the problem of increased energy consumption at the winter solstice.