• Title/Summary/Keyword: Architectural Lighting

Search Result 197, Processing Time 0.027 seconds

Verification and Development of Lighting Design Data for Office in Korea (Focused on the Evaluation of Lighting Energy and Cooling Load) (사무소를 위한 조명설계 자료의 개발과 검증 (조명에너지와 냉방부하를 중심으로))

  • Kim, Eun-Hee;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1043-1048
    • /
    • 2006
  • This paper aimed to verify and develop lighting design data for offices in Korea. It focused on a Korean standard office value relative to lighting density and the evaluation of lighting energy and cooling load. When planning indoor lighting design, we generally utilize the lighting density value which is set $14W/m^2$ by the ASHRAE/IES standard office value. However, the value is not appropriate to apply in Korea where higher efficiency lamps are more popular than others. For calculation of a proper lighting density of Korea, we analysed distribution curves of luminous intensity(2-lamp fluorescent lighting fixture with Parabolic) and derived the new lighting density $12.64W/m^2$ as Korea standard office value. In the simulation using this value, it was shown that lighting energy and cooling load could be reduced.

  • PDF

A Study on the Emotional Evaluation Model of LED Colors in Architectural Pacade (건축파사드 LED칼라의 감성평가모형 연구)

  • Yoo, Yong-Woo
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.101-111
    • /
    • 2012
  • The purpose of this study is to draw emotional evaluation model related to LED lighting colors and suggest basic informations that enable planned directions of architectural pacade lighting to simulate beforehand in a laboratory. As experimental methods, extracted PAD emotional evaluation model and then directed a experimental model of 10 LED lighting colors, studied and analyzed survey questions. The results are as follows; First, in the case of P(Pleasure-Unpleasure), Red, Yellow, Green, Cyan, Magenta, White and Combination of $G{\leftrightarrow}B$ Colors are satisfying, vibrant and positive distribution chart has shown. Second, in the case of A(Arousal-Unarousal), Red, Yellow, Green, Cyan, Blue, White and Combinations of $R{\leftrightarrow}G$, $G{\leftrightarrow}B$, $R{\leftrightarrow}B$ Colors, it makes a little difference, they have shown useful distribution chart to induce sight in a aroused state. Third, in the case of D(Dominance-Submissiveness), Red, Cyan, Green and Combinations of $G{\leftrightarrow}B$ Colors are free, controlling and extent of effect was excellent. On the contrary, in the case of Yellow and Magenta and Combinations of $R{\leftrightarrow}B$, they are gentle and arouse the protective instinct or feminine distribution chart has shown. Fourth, it showed difference of preference that difference of select ratios of both men and women in Orange, Blue, Greenish-Yellow (preference of man) and Magenta, Combinations of $R{\leftrightarrow}B$ Colors(preference of woman).

  • PDF

Development of the Air-Conditioning Unit for Workspace Integrated Units (사무공간의 통합유니트 구축을 위한 공조유니트 도출에 관한 연구)

  • Kim Ji-Hyun;Kim Sun-Sook;Yang In-Ho;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.669-680
    • /
    • 2005
  • The purpose of this study is to develop the air-conditioning unit combined with the lighting unit for workspace and to supply its performance data at architectural design stage. The air-conditioning unit is one of the components of a workspace integrated unit, which can be defined as the planning unit satisfying the environmental comfort criteria of workspace. Air-conditioning diffusers are classified according to throws and features by literature review and case study. Then diffusers are combined with the lighting unit. Through the CFD simulation, the thermal performance of each unit was evaluated and finally various air-conditioning units combined with the lighting units were developed.

Application of Lightself to Buildings as a Integrated Daylighting System (건축물 일체형으로서 광선반형 자연채광시스템의 건축물 적용기법에 관한 연구)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.17-24
    • /
    • 2002
  • For sustainable building design, using day lighting is considered a variable technique to save energy and create comfort indoor environments. Specially, the lightself as a integrated daylighting system is one of the most important techniques due to it's durability, availability and lighting performance. This paper aims to analyze the development and architectural application of a lightself system to buildings as a integrated day lighting system. For the study, advanced lightself systems developed in abroad such as "Integrated Enveloped and Lighting System", "Anidolic Daylighting System" and etc. are analyzed. Also, the architectural examples are investigated. As results, the new technologies such as optically treated reflective and sun-tracking are adopted to improve daylight performance. And, lots of environmentally friendly buildings are installed on integrated lightself system.

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • v.16 no.3
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.

Economic Feasibility Analysis on the Benefit of Daylighting Incorporation Devices under Clear Skies (주광연동 제어설비를 이용한 청공광의 경제성 평가)

  • Kim, Gon;Kim, Jeong-Tai
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.491-499
    • /
    • 2007
  • An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.

A Study on Sky Light Pollution based on Sky Glow in Jeju Island (스카이글루 분석을 통한 제주도 빛공해 실태조사)

  • Lee, So-Hyun;Lim, Hong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.83-91
    • /
    • 2018
  • Artificial lighting contributes greatly to developing civilizations. It allows daytime activities to continue throughout the dark hours of the day and thus increasing work productivity as well as allowing people to enjoy nighttime activities. In addition, artificial lighting is used to beautify landscapes, architectural monuments, and thus highlighting the social-economic development of a given place. However, excessive and improper usage of artificial lighting can lead to light pollution. Light pollution is a serious issue that is detrimental to human health. It has been linked to a number of health conditions including sleep disorder, visual discomfort as well as cancer. The effects of light pollution extend throughout the entire ecosystem, affecting both plants and animals. Furthermore, sky-glow from light pollution hinders astronomical observation. The current paper presents a study conducted on lit environment of a nightscape. The quality of the sky was measured in 144 spots using Sky Quality Meter (SQM) devices. The measured spots were chosen on the basis of land use as well as distance from the Halla Mountain.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting (수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가)

  • Jung, Hyun-Ji;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position (확산필름 부착 위치에 따른 광선반 성능개선 연구)

  • Park, Eunsu;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.