• Title/Summary/Keyword: Arch Types

Search Result 173, Processing Time 0.029 seconds

Interruption of the Aortic Arch Associated with Single Ventricle, D-Transposition of Great Vessels, and Patent Ductus Arteriosus -Report of A Case- (대동맥전환증 및 단일심실과 동반된 대동맥궁 결손 1례 보고)

  • 유병하
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.135-139
    • /
    • 1979
  • Interruption of the aortic arch may be defined as discontinuity of the aortic arch in which either an aortic branch vessel or a patent ductus arteriosus supplies the descending aorta. This uncommon lesion was described first by Raphe Steidele in 1778 and was later classified into 3 types by Celoria and Patton. This anomaly rarely occurs as an isolated anomaly. Most commonly, a ventricular septal defect, patent ductus arteriosus, and abnormal arrangement of the brachiocephalic arteries occurs together with arch anomaly. Rarely, more complex anomaly, such as transposition of the great vessel, or single ventricle, is coexistent. We present the case of an 6 year-old boy with D-transposition of great vessel single ventricle, patent ductus arteriosus and patent foramen ovale with interruption of the aortic arch (Type A).

  • PDF

The Study on Shape Behavior of Nielsen Arch Bridge Considering Rise Ratio (라이즈비를 고려한 닐센아치교의 형상 거동에 관한 연구)

  • Park, Soon-Eung;Park, Moon-Ho;Kim, Jin-Kyu;Roh, Woo-Hyuk;Cho, Seong-Uk;Ryu, Ji-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.3
    • /
    • pp.161-168
    • /
    • 2010
  • Recently, bridges have been momenttous as not only regarding function but also concerning aesthetics. However, when beauty is considered in the bridge, it is also essential that stability and economics be considered. Besides, when considering stability, an arch bridge is one of the most stable structures. The most important element is a rise ratio when regarding beauty and economics of arch bridges. The effect of dead load and DB24 load have been considered to decide proper rise ratio. Therefore, in this study, examined the value of moment, displacement and member forces, in the variation of the rise ratio of arch bridges. The most optimum shape of Nielsen arch bridges has determined by analyzing member forces, moments and displacement with parameters of rise ratio and angle of vertical members. By comparison between values, the hanger types have been also considered to derive the optimum shape of Nielsen arch bridge.

  • PDF

A Stability Study of Rider Arch under the Increased Load of Checker Brick in Regernerator of the Reformed Glass Melting Furnace (유리 용해로 축열실 상재 하중 증가에 따른 Rider Arch의 안전성 검토)

  • Lee, Sun-Yung;Kim, Jong-Ock;Lim, Dae-Young;Kim, Taik-Nam;Park, Won-Kya
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.125-131
    • /
    • 1997
  • The regenerator is important part of the glass melting furnace to increase the temperature of the intake air through the combustion flame. The insulation, checker brick, prevention of the air leak has been studied to decrease the fuel consumption in glass melting industries. Thus the new types of checker brick and the design of the rider arch has been studied to prolong the life of the glass melting furnace. The height of the regenerator increased from 5.64 m to 7.89 m in the reforming of the glass melting furnace. Thus the stability of the rider arch is studied under the condition of increased load of checker brick in this research. The rider arch was estimated to be stable inspite of the increase of load according to the calculation. The max. sustained compressive stress of the rider arch is 163 kg/$cm^2$ and the max. sustained shear stress is 6.37 kg/$cm^2$.

  • PDF

3D printed midsole design according to the sole types of elementary school students

  • Lim, Ho Sun
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.3
    • /
    • pp.315-323
    • /
    • 2016
  • The present study is intended to study sole types necessary for shoe designs for elementary school students that are in age groups in growth periods, and 3D midsole design utilizing 3D printing technology. This study analyzed data from the 3D measurement of the feet of 1,227 elementary school students aged 7-13 years residing in the capital region conducted as part of the 6th Anthropometry of Size Korea. In addition, 3D midsoles by sole type were designed utilizing a Rhino CAD, and midsole prototypes were output utilizing a Zortrax-M200 3D Printer. Through a cluster analysis of sole shapes by type, sole shapes were classified into three types. Type 1 has small values of foot lengths and foot breadths, with large toe 1 angles and high arch heights. Type 2 has intermediate values of foot lengths and foot breadths, with small toe 1 angles and high arch heights. Type 3 has large values of foot lengths and foot breadths with small toe 1 angles and low arch heights. On reviewing the results of design of 3D midsoles by sole type, it can be seen that the midsoles were designed according to characteristics by sole type. The results of the sole type analysis in the present study are expected to be meaningful as basic data for the development of shoe insoles for elementary school students.

Dynamic Behavior Characteristics According to Arch Types of Arched Stone Bridge Subjected to Seismic Load (지진 하중을 받는 홍예교의 아치 형태에 따른 동적 거동 특성)

  • Kim, Ho-Soo;Lee, Seung-Hee;Jeon, Gun-Woo;Bang, Hyeok-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.45-55
    • /
    • 2018
  • The arched stone bridge has been continuously deteriorated and damaged by the weathering and corrosion over time, and also natural disaster such as earthquake has added the damage. However, masonry stone bridge has the behavior characteristics as discontinuum structure and is very vulnerable to lateral load such as earthquake. So, it is necessary to analyze the dynamic behavior characteristics according to various design variables of arched stone bridge under seismic loads. To this end, the arched stone bridge can be classified according to arch types, and then the discrete element method is applied for the structural modelling and analysis. In addition, seismic loads according to return periods are generated and the dynamic analysis considering the discontinuity characteristics is carried out. Finally, the dynamic behavior characteristics are evaluated through the structural safety estimation for slip condition.

Structural behavior of arch dams considering experimentally validated prototype model using similitude and scaling laws

  • Altunisik, Ahmet Can;Kalkan, Ebru;Basaga, Hasan B.
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.101-116
    • /
    • 2018
  • As one of the most important engineering structures, arch dams are huge constructions built with human hands and have strategical importance. Because of the fact that long construction duration, water supply, financial reasons, major loss of life and material since failure etc., the design of arch dams is very important problem and should be done by expert engineers to determine the structural behavior more accurately. Finite element analyses and non-destructive experimental measurements can be used to investigate the structural response, but there are some difficulties such as spending a long time while modelling, analysis and in-situ testing. Therefore, it is more useful to conduct the research on the laboratory conditions and to transform the obtained results into real constructions. Within the scope of this study, it is aimed to determine the structural behavior of arch dams considering experimentally validated prototype laboratory model using similitude and scaling laws. Type-1 arch dam, which is one of five arch dam types suggested at the "Arch Dams" Symposium in England in 1968 is selected as reference prototype model. The dam is built considering dam-reservoir-foundation interaction and ambient vibration tests are performed to validate the finite element results such as dynamic characteristics, displacements, principal stresses and strains. These results are considered as reference parameters and used to determine the real arch dam response with different scales factors such as 335, 400, 416.67 and 450. These values are selected by considering previously examined dam projects. Arch heights are calculated as 201 m, 240 m, 250 m and 270 m, respectively. The structural response is investigated between the model and prototype by using similarity requirements, field equations, scaling laws etc. To validate these results, finite element models are enlarged in the same scales and analyses are repeated to obtain the dynamic characteristics, displacements, principal stresses and strains. At the end of the study, it is seen that there is a good agreement between all results obtained by similarity requirements with scaling laws and enlarged finite element models.

Proposal for a modified classification of isolated zygomatic arch fractures

  • Jung, Seil;Yoon, Sihyun;Nam, Sang Hyun
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.111-118
    • /
    • 2022
  • Background: Although the zygomatic arch is an important structure determining facial prominence and width, no consensus exists regarding the classification of isolated zygomatic arch fractures, and the literature on this topic is scarce. To date, five papers have subdivided zygomatic arch fractures; however, only one of those proposed classifications includes the injury vector, although the injury vector is one of the most important factors to consider in fracture cases. Furthermore, the only classification that does include the injury vector is too complicated to be suitable for daily practice. In addition, the existing classifications are clinically limited because they do not consider greenstick fractures, nondisplaced fractures, or coronoid impingement. In the present study, we present a rearrangement of the previously published classifications and propose a modified classification of isolated zygomatic arch fractures that maximizes the advantages and overcomes the disadvantages of previous classification systems. Methods: The classification criteria for isolated zygomatic arch fractures described in five previous studies were analyzed, rearranged, and supplemented to generate a modified classification. The medical records, radiographs, and facial bone computed tomography findings of 134 patients with isolated zygomatic arch fractures who visited our hospital between January 2010 and December 2019 were also retrospectively analyzed. Results: We analyzed major classification criteria (displacement, the force vector of the injury, V-shaped fracture, and coronoid impingement) for isolated zygomatic arch fracture from the five previous studies and developed a modified classification by subdividing zygomatic arch fractures. We applied the modified classification to cases of isolated zygomatic arch fracture at our hospital. The surgery rate and injury severity differed significantly from fracture types I to VI. Conclusion: Using our modified classification, we could determine that both the injury force and the injury vector meaningfully influenced the surgery rate and the severity of the injuries.

The Seismic Response According to Rise-Span Ratio of the Arch Structure With Seismic Isolation (라이즈-스팬비에 따른 면진 아치구조물의 지진응답 분석)

  • Kim, Su-Geun;Kim, Yu-Seong;Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2018
  • In order to reduce the seismic response of the spatial structure, a seismic isolation system with sufficient flexibility is used. The natural period of structure with seismic isolation system got be long to avoid prominent period. In this study, The seismic response of the truss-arch structure, which is modeled in three types according to the rise-span ratio is analyzed on El-centro, Northridge and Artificial Earthquake and compared with the seismic response of the truss-arch structure with lead rubber bearing(LRB). When seismic load is applied to the truss arch with isolation system, the horizontal acceleration response of the truss arch is reduced and vertical seismic response is also reduced. The application of the seismic isolation system is effective in controlling the seismic response.

Development of a System of Temporary Arch Bridges by Using Snap-fit GFRP Composite Decks (조립식 복합소재 아치구조를 이용한 가교 시스템 개발)

  • Cho, Yong-Sang;Lee, Sung-Woo;Hong, Kee-Jeung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.276-281
    • /
    • 2008
  • Glass-fiber reinforced polyester(GFRP) composite material is a promising alternative to existing construction materials such as steel, concrete and wood. One of passible applications of GFRP composite material is to build temporary bridges by assembling GFRP composite decks. In this paper, we develop a system of temporary arch bridges that can be built by easy assembling of GFRP composite decks. For this purpose, several types of temporary arch bridges are suggested and verified by FE analysis.

  • PDF

THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD (CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구)

  • Row, Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.17-32
    • /
    • 1996
  • It is important to understand the operating mechanism and force system of fixed appliance that most effective for individual tooth movement in various orthodontic appliances. The archwire system of fixed appliance is devided into 3 types, which is continuous arch, segmented arch and sectional arch. The last two types have longer interbracket distance and simple force operating points, so it is easy to control force system by operator. But the continuous arch has shorter interbracket distance and various bracket geometry, so it is hard to control and anaylze the force system. The purpose of this study was three dimentional force and moment analysis of continuous arch system by finite element method, which is similar situation to three dimentional elastic beam in structural engineering. Several sample form of various bracket geometry and artificial lower crowding typodont made by author were constructed, analyzed and compared each other. The results were as follows : 1. The force magnitude is linear proportional to the degree of displacement or tilting of the bracket. 2. The force magnitude is inversely non-linear proportional to the interbracket distance. 3. In three dimensional typodont model, while the force can be compared with that of the sample form in the area where adjacent bracket geometry is simple, the force is much more than the expected value in the area where adjacent bracket geometry is complex.

  • PDF