• Title/Summary/Keyword: ArcCheck

Search Result 58, Processing Time 0.023 seconds

WELDING-INDUCED BUCKLING INSTABILITIES IN THIN PLATES

  • Han, Myoung-Soo;Tsai, Chon-Liang
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.661-667
    • /
    • 2002
  • Welding-induced buckling distortion is one of the most problematic concerns in both design and fabrication of welded thin-plate structures. This paper deals with experimental and numerical results of the welding-induced longitudinal and/or buckling distortion occurring in welding of 6mm-thick AH36 high strength steel plates. Effects of the heat input and the plate size on the distortion were experimentally evaluated for square plates. Bead-on-plate welding was performed with the submerged arc welding process along the middle line of plate specimens. Experimental results showed that the longitudinal distortion made a single curvature in the plate, and the distortion magnitude along the weld centerline was proportional to the heat input and the plate size. The experimental results were used to examine the validity of the numerical simulation procedure for welding-induced distortion where the longitudinal distortion mode and magnitude were numerically quantified. Three-dimensional, large deformation, welding simulations were performed for selected weld models. Numerical results of the distortion mode and magnitude were in a good agreement with experimental ones. Depending on the presence of halting the distortion growth during the cooling cycle of welding, the condition discriminating buckling distortion from longitudinal distortion was established. Eigenvalue analyses were performed to check the buckling instability of tested plates with different sizes subjected to different heat inputs. The perturbation load pattern for the analysis was extracted from longitudinal inherent strain distributions. Critical buckling curve from the eigenvalue analyses revealed that the buckling instability is manifested when plate size or heat input increases.

  • PDF

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

Dynamic Data Cubes Over Data Streams (데이타 스트림에서 동적 데이타 큐브)

  • Seo, Dae-Hong;Yang, Woo-Sock;Lee, Won-Suk
    • Journal of KIISE:Databases
    • /
    • v.35 no.4
    • /
    • pp.319-332
    • /
    • 2008
  • Data cube, which is multi-dimensional data model, have been successfully applied in many cases of multi-dimensional data analysis, and is still being researched to be applied in data stream analysis. Data stream is being generated in real-time, incessant, immense, and volatile manner. The distribution characteristics of data arc changing rapidly due to those characteristics, so the primary rule of handling data stream is to check once and dispose it. For those characteristics, users are more interested in high support attribute values observed rather than the entire attribute values over data streams. This paper propose dynamic data cube for applying data cube to data stream environment. Dynamic data cube specify user's interested area by the support ratio of attribute value, and dynamically manage the attribute values by grouping each other. By doing this it reduce the memory usage and process time. And it can efficiently shows or emphasize user's interested area by increasing the granularity for attributes that have higher support. We perform experiments to verify how efficiently dynamic data cube works in limited memory usage.

Three Cases of Chronic Adult Atopic Dermatitis (만성 성인형 아토피 피부염의 한방 치험 3례)

  • Ku, Young-Hui;Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.1
    • /
    • pp.140-150
    • /
    • 2002
  • Introduction: Atopic dermatitis is chronic eczematous dermatosis which is related strongly to a family history of atopic disease and hereditary disposition. Its threshold of itching is low so that severe itching occurs and causes secondary eczema. Adult atopic dermatitis has mostly severe symptoms and progresses to chronic relapsing. Objective: The purpose of this study was to estimate the efficacy of oriental medical treatment and management on chronic adult atopic dermatitis. Subject: We studied 3 patients who visited Dongguk University Gangnam Oriental Hospital Dept. of Dermatol. with chronic adult atopic dermatitis from August 2001 to April 2002 and were observed for over 4 months. Methods: We treated them with herb-medication, acupuncture, negative therapy, aroma therapy, full spectrum visible ray therapy(by carbon arc) and external application(Jaun-go). We used the SCORAD index to assess the severity of atopic dermatitis. Results: There were 3 patients with chronic adult atopic dermatitis we could check for over 4 months by clinical scoring using the SCORAD system. 1. The grades of the severity of atopic dermatitis were lower only by the oriental medical treatments and management. 2. Intensities of relapse cases were lower then before the oriental medical treatments. 3. The secondary treatment term for relapse cases was shorter then the first treatment term after oriental remedies were used. Conclusion: Considering the above results, more study is needed on the chronic relapse cases with adult atopic dermatitis, the factors of increasing seventy of adult atopic dermatitis, the prognostic factors of adult atopic dermatitis, and the clinical interchange of chronic adult atopic dermatitis between oriental medicine and western medicine.

  • PDF

Comparative analysis of weldability using a three-point bending test of a movable iron core welder and a digital welder that outputs a sine wave (가동 철심형 용접기와 정현파를 출력하는 디지털 용접기의 3점식 굽힘시험을 이용한 용접성 비교 분석)

  • Jong-Sig Kim;Kwang-Ho Lee;Yi-Hwan Joo;Jong-Chul Koh;Gyeong-Yeol Yun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.605-611
    • /
    • 2023
  • In this study, in order to reduce energy that affects the natural environment, a moving iron core type welding machine and a digital welding machine (inverter type) with low power consumption are compared in shielded arc welding, and the parts that use less power and have the same weldability conditions are identified. want to check. The movable iron core welder uses alternating current that outputs a sine wave, and the digital welder also generates a sine wave alternating current, so it must have the same conditions, low power consumption, and the same weldability. However, weldability can be verified in various ways, but the analysis is limited to the qualification test in the field of national technical qualification welding.

Post-treatment stability of the occlusal plane according to different vertical facial patterns (수직적 안모유헝에 따른 치료 후 교합평면 안정성에 관한 연구)

  • Park, Jung-Eun;Lee, Jin-Woo;Chung, Dong-Hwa;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.369-379
    • /
    • 2006
  • Objective: The purpose of this study was to find changes in the occlusal plane related to different vertical facial patterns and suggest treatment goals and conduct possible treatment mechanisms. Methods: 60 adult patients (28 males, 32 females) who had been diagnosed as Class 1 skeletal malocclusion and treated without extraction were selected. Patients were divided into three groups; short face type (group 1), average face type (group 2) and long face type (group 3), using the data on normal occlusion of Korean adults. Results: The results were achieved by analyzing cephalometric tracings of each group at pre-treatment, end-treatment and post-treatment (about 1 year recall check). The inclination of the occlusion plane tends to gradually increase as the face becomes longer In group 1, COP-X, FOP-X, L6/L1, MP-L6 were significantly decreased, and L1-FOP was significantly increased during the retention period (T3-T2). Group 2 showed no significant change, In group 3, FOP-X was significantly increased during the retention period (T3-T2). During the retention period, FOP-X showed significant change among each group, especially between group 1 and group 3. Conclusion: These results suggest that changes of occlusal plane inclination according to facial vertical pattern need to be considered during the retention period for intrusion, extrusion, and incisor overbite.

Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Algorithms in Patient Specific VMAT QA

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Background: The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Materials and Methods: Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. Results and Discussion: For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were $97.2%{\pm}2.3%$, and $99.4%{\pm}1.1%$, respectively while those for 15 MV were $98.5%{\pm}0.85%$ and $99.8%{\pm}0.2%$, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. Conclusion: The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device.

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.