• Title/Summary/Keyword: Arc pressure distribution

Search Result 49, Processing Time 0.027 seconds

Neutral Beam Evolution in the KSTAR NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The pressure distributions in the test stand built for developing KSTAR NBI ion sources were obtained using a network system composed of conductance elements modeling the ion source, the neutralizer, and other beam line components. The allowable regime was defined on the coordinates of the gas supply rate to the ion source and the neutralizer, considering the proper conditions of the three critical parameters, the ion source pressure for good arc discharge, the pressure integral in the neutralizer for sufficient neutralization, and the chamber pressure for minimum neutral beam loss. The neutral beam evolution along the path from the ion source extraction grid to the calorimeter through the neutralizer, the bending magnet and the vacuum chamber was estimated for typical pressure distributions.

  • PDF

Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition (정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가)

  • Pak, Bock-Choon;Kim, Joon-Woo;Baek, Byoung-Joon;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Production of Hydrogen from Methane by 3phase AC GlidArc Plasma (3상 교류 부채꼴 방전을 이용한 메탄으로부터 수소 생산)

  • Chun, Young-Nam;Kim, Seong-Cheon;Lim, Mun-Seup
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2232-2237
    • /
    • 2007
  • Steam reforming and catalytic reforming of $CH_4$ conversion to produce synthesis gas require both high temperatures and high pressure. Non-thermal plasma is considered to be a promising technology for the hydrogen rich gas production from methane. In this study, three phase AC GlidArc plasma system was employed to investigate the effects of gas composition, gas flow rate, catalyst reactor temperature and applied electric power on the $CH_4$ and $H_2$ yield and the product distribution. The studied system consisted of three electrode and it connected AC generate power system different voltages. In this study, air was used for the partial oxidation of methane. The results showed that increasing gas flow rate, catalyst reactor temperature, or electric power enhanced $CH_4$ conversion and $H_2$ concentration. The reference conditions were found at a $O_2$/C molar ratio of 0.45, a feed flow rate of 4.9 ${\ell}$/min, and input power of 1kW for the maximum conversions of $CH_4$ with a high selectivity of $H_2$ and a low reactor energy density.

  • PDF

ARC Discharge Sound Source in Underwater (수중 아-크 방전음원에 관한 연구)

  • Chang, Jea-Hwan;Chang, Jee-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.12-18
    • /
    • 1985
  • In general the impulse sound sources of underwater generated by electric arc discharge had used static energy of the charged capacitors. The author proposed an underwater arc discharge sound source using secondary voltage of high voltage transformer without capacitors. The arc discharge device was composed of a high voltage transformer and a switching system. The impulse current in the primary turn of the high voltage transformer is controlled by the switching system and inductive current of the secondary turn in the high voltage transformer is used in making impulsive arc discharge. A series of experiment have been carried out to observe the acoustic characteristics of the impulse sound source generated by the arc discharge. The results obtained were as follows: 1. Secondary current at the time of arc discharge keeps after ohm's law in the beginning and the maximum current flows out as soon as arc discharge breaks out. 2. A time difference between a start of applied current and a generation of arc discharge sound is the 3msec and it is generated arc sound when breaking down electric insulation at maximum voltage. 3. The sharper the end of electrodes and the higher the secondary voltage, the higher the sound pressure level. 4. Arc discharge sound was generated even at the distance of 100cm between electrodes and was stably reproductive at the gap of 1cm to 100cm. 5. Electric arc discharge sound wave is a shock wave of pulse-width of 0.15msec and spectral distribution of it is plenty of low frequency components less than 10 KHz.

  • PDF

Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness (극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Hwang, In-Sung;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

Calculation of Pressure Rise in the Puffer Cylinder of EHV GCB Without Arc (무부하시의 초고압 GCB의 파퍼실린더 내부의 상승압력 계산)

  • Park, K.Y.;Song, K.D.;Choi, Y.K.;Shin, Y.J.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1559-1561
    • /
    • 1994
  • At present, the principle of puffer action in high current interruption is adopted in almost of the EHV(Extra High Voltage) and UHV(Ultra High Voltage) GCB(Gas Circuit Breakers). The thermal interruption capability of these GCBs critically depends on the pressure rise in the puffer cylinder at current zero. The pressure rise in the puffer cylinder depends on the puffer cylinder volume, flow passage and leakage area in the interrupter, stroke curve etc. Recently commercial CFD(Computational Fluid Dynamics ) packages have been widely adopted to calculate the pressure distribution in the interrupter. However, there are still several problems with it, e.g. very expensive price, moving boundary problem, computation time, difficulty in using the package etc. Thus, the calculation of the puffer cylinder pressure in simple and relatively correct method is essential in early stage of GCB design. In these paper, the model ing technique and computed results for EHV class GCB (HICO, 145kV 40kA and 362kV 40kA GCB) are presented and compared with available measured results.

  • PDF

Characterization of Nanoparticles from Welding and Grinding Processes: Evaluation of Number Concentration and Size Distribution (용접 및 연마에서 발생되는 나노입자 특성 평가 : 수농도 및 입경분포 분석)

  • Kim, Boowook;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Objectives: This study aimed to characterize the nanoparticles produced by welding and grinding processes. Methods: The number concentrations of particles were mapped to determine the distribution of welding fumes in a workplace atmosphere using a hand-held condensation particle counter. An electrical low-pressure impactor was used for measuring the number concentration and particle size distribution. Results: High number concentrations were found around arc cutting and welding (grinding) processes. In the worker's breathing zone, the mean number concentration was 655,000 particles/cm3 and the count median diameter (CMD) was 84 nm with several multi peak distributions (~20, 70, 300 nm). However, at a distance of 3 m from the welding position, the number concentration decreased to 153,000 particles/cm3 with a 70 nm single peak size distribution. During a grinding process, peaks with high concentrations of nanoparticles were temporarily observed. The mean number concentration was 1,520,000 particles/cm3, and the CMD was 30 nm. Nanoparticles (<100 nm) made up 58% and 92% of the aerosols produced by welding and grinding processes, respectively.

Assessment of Human Impact on Mekong River Flood by Using Satellite Nightlight Image

  • Try, Sophal;Lee, Giha;Lee, Daeeop;Thuy, HoangThu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.187-187
    • /
    • 2016
  • High intensity of population distribution in deltaic setting especially in Asia tends to have increased and causes coastal flood risk due to lower elevations and significant subsidence. Maximum or peak discharge of flood always causes numerous deaths and huge economic losses. New technology of spatial satellite image has been applied to analyze flood damage. In this research, the relationship of nightlight intensity associated with flood damages has been determined during 1992-2013 with spatial resolution of 30 arc sec ($0.0083^{\circ}$) which is nearly one kilometer at the equator in whole six countries along the Mekong River (i.e., China, Myanmar, Lao PDR, Thailand, Cambodia and Vietnam). ArcGIS Hydrological Flow Length Tool has been used to determine the distance of each pixel areas from the rivers and streams. Statistical analysis results highlight the significant correlation R = 0.47 between nightlight digital number and economic damages per unit area (US$/km2) and R = 0.62 for number of affected people for unit area ($people/km^2$). The areas near by the Mekong River and its tributaries correspond to high flood damage. This spatial analysis result is going to be prestigious key information to the regions and all related stakeholders for decisions and mitigation strategies.

  • PDF

Parameter Study for the Analysis of Impact Characteristics considering Dynamic Material Properties (동적 물성치를 고려한 V.I. 충격인자의 영향 분석)

  • Lim, J.H.;Song, J.H.;Huh, H.;Park, W.J.;Oh, I.S.;Choe, J.W.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.945-950
    • /
    • 2001
  • Vacuum interrupters that is used in various switchgear components such as circuit breakers, distribution switches, contactors, etc. spreads the arc uniformly over the surface of the contacts. The electrode of vacuum interrupters is used sintered Cu-Cr material satisfied with good electrical and mechanical characteristics. Because the closing velocity is 1-3m/s, the deformation of the material of electrodes depends on the strain rate and the dynamic behavior of the sintered Cu-Cr material is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain-rate is obtained from the split Hopkinson pressure bar test using cylinder type specimens. Experimental results from both quasi-static and dynamic compressive tests with the split Hopkinson pressure bar apparatus are interpolated to construct the Johnson-Cook equation as the constitutive relation that should be applied to simulation of the dynamic behavior of electrodes. To evaluate impact characteristic of a vacuum interrupter, simulation is carried out with five parameters such as initial velocity, added mass of a movable electrode, wipe spring constant, initial offset of a wipe spring and virtual fixed spring constant.

  • PDF