• 제목/요약/키워드: Arc light intensity

검색결과 30건 처리시간 0.019초

GMA용접의 아크빛 모델 및 용접선 추적에의 응용 (Modeling of Are Light Intensity and Its Application to Weld Seam Tracking in GMAW)

  • 유용상;최상균;유중돈;선우희권
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.113-121
    • /
    • 1996
  • The arc sensor has been most widely used for weld seam tracking through welding current or voltage variation. In this work, the relation between the arc light intensity and welding condition is investigated using heat balance in the Plasma for its possible application to seam tracking in the GMAW process. The arc light intensity is derived to be the function of the arc length and welding current Experiments are carried out to verify the proposed heat balance model. Performances of least square and integration methods to process the signals for seam tracking are compared experimentally. Predicted arc light intensity shows reasonably good agreement with experimental results. The weld seam is successfully tracked through the arc light intensity. The least square and integration methods demonstrate almost same performance of seam tracking with $CO_2$gas shielding.

  • PDF

세라믹 메탈할라이드 램프의 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal-Halide Lamps)

  • 김우영;장혁진;양종경;박형준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.378-379
    • /
    • 2009
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

  • PDF

물체의 반사성질이 용접자동화용 시각센서의 아크노이즈에 미치는 영향에 관한 연구 (The Influence of the Reflected Arc Light on Vision Sensors for Welding Process Autimation)

  • 이철원;나석주
    • Journal of Welding and Joining
    • /
    • 제13권1호
    • /
    • pp.115-126
    • /
    • 1995
  • Vision sensors using the optical triangulation have been widely used for automatic welding systems in various ways, but their reliability is seriously affected by presence of the arc noise. The reliability of vision sensors was analyzed with variation of the arc noise by considering the reflectance of the base metal. first, the properties of the base metal's reflection were modelled by using the Bidirectional Reflectance-Distribution Function(BRDF), and then the variation of the reflected arc intensity was formulated for various configurations of the torch, base metal, and sensor. The experimental data of the gray level of the reflected arc light were obtained for two materials, mild steel and stainless steel. It was found that the results calculated from the proposed model were in good agreement with the experimental data.

  • PDF

광원에 따른 조사거리의 증가가 복합레진의 중합도에 미치는 영향 (INFLUENCE OF TIP DISTANCE ON DEGREE OF CONVERSION OF COMPOSITE RESIN IN CURING WITH VARIOUS LIGHT SOURCES)

  • 김상배;박호원
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.273-279
    • /
    • 2004
  • 최근에 소개된 single high-intensity LED 중합기는 이전의 LED 중합기에 비해 높은 광도를 가지며 짧은 중합시간에 적절한 물성을 가질 수 있다고 한다. 본 연구는 single high-intensity LED 중합기의 중합성능을 평가하기 위하여 거리에 따른 중합도를 조사하였다. Mylar strip사이에 복합레진(Filtek Z250)을 넣고 압접시켜 만든 얇은 필름형 시편을 LED 중합기(Elipar Freelight 2, 10초), 플라스마 중합기(Flipo, 6초)와 할로겐 중합기 (XL3000, 20초)를 사용해 0mm, 2mm, 4mm, 6mm에서 광도를 측정하고 중합시켰다. 중합된 시편을 Fourier Transform Infrared Spectrometer(FTIR)를 이용해 중합도를 측정한 후 다음과 같은 결론을 얻었다. 1. 모든 중합기에서 거리가 증가할수록 유의하게 광도가 감소하였으며 LED중합기의 경우 6mm에서 다른 중합기에 비해 가장 많은 광도 감소율을 보였다(p<0.05). 2. 모든 중합기에서 거리가 증가함에 따라 4mm까지는 중합도가 감소하였지만 유의한 차이는 보이지 않았다(p>0.05). 하지만 4mm와 6mm사이에서는 모든 중합기에서 유의하게 감소하였다(p<0.05). 3. 각 거리에 따른 중합기간의 중합도 차이는 0mm, 2mm, 4 mm에서 LED중합기가 다른 중합기보다 유의하게 높은 중합도를 보였으며 (p<0.05) 플라스마 중합기와 할로겐 중합기 사이에서는 유의한 차이가 없었다. 하지만 6 mm에서는 모든 중합기 사이에 유의한 차이를 보이지 않았다(p>0.05).

  • PDF

Halogen lamp 광조사기와 Plasma xenon arc lamp 광조사기에 의한 광중합 복합레진의 중합률 비교 (COMPARISON OF THE DECREE OF CONVERSION IN LIGHT-CURED COMPOSITE RESIN CURED BY HALOGEN AND PLASMA XENON ARC LAMP CURING UNIT)

  • 이영준;정병초;최남기;양규호
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.328-336
    • /
    • 2002
  • 본 연구의 목적은 일반 halogen lamp 광조사기와 비교하여 plasma xenon arc lamp 광조사기의 광중합 능력을 평가하기 위한 것이다. 7mm의 내경과 1mm, 2mm, 3mm 두께를 갖는 레진 시편을 aluminum 주형상에서 제작하여 plasma xenon arc lamp 광조사기는 2초, 3초, 6초, halogen lamp 광조사기는 20초, 40초, 60초 동안 광조사한 후 Raman spectroscopy를 이용하여 레진 시편 표면과 후면의 중합률을 측정하였다. 표면 중합률은 광조사 시간이 증가함에 따라 halogen lamp 광조사기와 plasma xenon arc lamp 광조사기 모두에서 유의성있게 증가하였으며 전반적인 중합률은 halogen lamp 광조사기에서 더 높았으나 plasma xenon arc lamp 광조사기와 유의한 차이는 없었다. 광조사 시간이 증가함에 따라 halogen lamp 광조사기의 경우 후면 중합률은 모든 두께에서 점차 증가하였으나 1.2mm 두께에서는 유의한 차이가 없었으며 plasma xenon arc lamp 광조사기로 중합한 경우에는 모든 두께에서 조사시간이 증가할수록 중합률은 유의성있게 증가하였다. 이상의 결과로 plasma xenon arc lamp 광조사기의 강한 광도가 광조사 시간의 감소를 완전히 보상하지는 못하는 것으로 판단되므로 plasma xenon arc lamp 광조사기로 광중합 복합레진을 중합할 경우 2mm이내의 적층 충전이 요구되며 또한 제조회사가 제시한 조사 시간보다 추가적인 광조사가 필요할 것으로 판단된다.

  • PDF

세라믹 메탈할라이드 램프 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal Halide lamps)

  • 이주호;양종경;김남군;장혁진;박대희
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2244-2248
    • /
    • 2008
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

Effect of light source on depth of cure and polymerization shrinkage of composites

  • Na, Joon-Sok;Oh, Won-Mann;Hwang, In-Nam
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.578.1-578
    • /
    • 2001
  • The aim of this study was to evaluate the efficiency of the recently introduced light curing units to polymerize a light curing resin composite. Four light curing units XL 3000, Optilux 500 for halogen light source, Apollo 95E for plasma arc and Easy cure for LED (blue-light Emitting Diode) were evaluated. Radiometer was used for measure the light intensity.(omitted)

  • PDF

소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구 (Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal)

  • 이경희;최영욱
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진;양종경;이종찬;김우영;신익태;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF