• 제목/요약/키워드: Arc discharge current

검색결과 99건 처리시간 0.031초

Discharge Characteristics of a KSTAR NBI Ion Source

  • Chang Doo-Hee;Oh Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.226-233
    • /
    • 2003
  • The discharge characteristics of a prototype ion source was investigated, which was developed and upgraded for the NBI (Neutral Beam Injection) heating system of KSTAR (Korea Superconducting Tokamak Advanced Research). The ion source was designed for the arc discharge of magnetic bucket chamber with multi-pole cusp fields. The ion source was discharged by the emission-limited mode with the control of filament heating voltage. The maximum ion density was 4 times larger than the previous discharge controlled by a space-charge-limited mode with fully heated filament. The plasma (ion) density and arc current were proportional to the filament voltage, but the discharge efficiency was inversely proportional to the operating pressure of hydrogen gas. The maximum ion density and arc current were obtained with constant arc voltage ($80{\sim}100V$), as $8{\times}10^{11}cm^{-3}$ and 1200 A, respectively. The estimated maximum beam current was about 35 A, extracted by the accelerating voltage of 80kV.

센서없는 AFCI 알고리즘 설계 (AFCI algorithm design without sensor)

  • 반기종;최성대;윤광호;김상훈;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.231-233
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this paper, arc discharge currents within power lines are being detected through the arc current control algorithm.

  • PDF

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

광계측기를 이용한 전차선-팬터그래프 재질별 이선아크 스펙트럼 분석 (Analysis of Contact Loss Arc Spectrum between Contact Wire and Pantograph Material using a Spectrometer)

  • 장진영;정노건;박종국;구경완;김재문
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1803-1808
    • /
    • 2013
  • To maintain contact between catenary and pantograph copper is important in order to transmit power smoothly on Current collection system. But, Arc discharge with strong light is generated because of contact loss. Therefore, Arc discharge detection is important measurement factor judging performance of current collection system. In this paper, It is described to results of arc discharge applying UV detection technology using arc generator. And Arc discharge was detected using the most commonly used processing catenary and rigid catenary and pantograph copper of electric rolling stock for securing arc detection instrument reliability. Results of contact loss detection instrument in this paper will be used for maintenance of current collection quality and system.

아크 전류 차단을 위한 제어알고리즘 개발 (Control Algorithm Development for an Arc Current Interruption)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권3호
    • /
    • pp.166-172
    • /
    • 2004
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this Paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc Is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional control algorithm does not have the arc current interrupt function. Hence, Control algorithm of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

DC 전류에 의한 직렬 아크 특성 분석 (Analysis of Serial Arc with DC Current)

  • 반기종;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1700-1701
    • /
    • 2007
  • DC Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, DC arc detection device is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

센서없는 아크고장전류 제어 알고리즘 설계 (Design of Control a Algorithm for Arc Fault Current without Current Sensor)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권6호
    • /
    • pp.255-260
    • /
    • 2006
  • Arc Fault Current is an which occurrs in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this parer, arc discharge currents within power lines are being detected through the arc current control algorithm.

아크의 방전에 따른 전기안전에 미치는 영향 (Interruption Controller Design of Arc current With Custom Electric Source)

  • 반기종;임승하;원영진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.1283-1286
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

방전가공기용 액체 절연재료의 아크 방전 특성 연구 (A study on the arc discharge characteristics of liquid insulating materials for electrical discharge machine)

  • 김상현;김해종;마대영;신태민
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.564-571
    • /
    • 1995
  • This paper deals with the arc discharge characteristics of kerosene oil as a basic study on electrical discharge machine. Using needle electrode the discharge voltage, discharge current, discharge energy and the shape of discharge crater are measured. In consequence, it becomes clear that the discharge crater(depth, height, diameter) is depending on the discharge energy. Rapid increase in depth, height and diameter of discharge crater was observed during initial discharge, where discharge energy is large. However, rather slow decrease of those values was found when discharge energy is low or N is more than 3. As the ratio of $I_p$$T_on$ increase, the shape of discharge crater gets near circle. The protuberances of the discharge crater were not formed by the melted needle electrode but by the that of work piece.

  • PDF

전기화재 방지를 위한 아크고장전류 차단기 설계 (Arc Fault Circuit Interrupter Design for Electrical Fire Protection)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.220-225
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc fault circuit interrupter does not have the arc current interrupt function. Hence, Arc current controller is designed for the interruption of arc fault current which has the modified arc characteristics.