• Title/Summary/Keyword: Arc Discharge

Search Result 372, Processing Time 0.024 seconds

Study on the Properties of Surface Treatmented Fly Ash using Arc Discharge (아크방전을 이용해 표면개질 된 플라이애시의 특성에 관한 연구)

  • Park, sun-gyu;Kim, sun-a;Kim, hyeon-sung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.273-274
    • /
    • 2018
  • 플라이애시를 콘크리트의 혼화재로서 사용하기 위해서는 미연탄소 제거 및 알칼리 자극제의 첨가가 요구된다. 이러한 문제점을 해결하기 위해 현재까지 플라즈마를 이용한 플라이애시의 표면개질에 관한 연구가 진행되었으나, 플라즈마는 오존을 생성하는 문제점을 지니고 있다. 따라서 본 연구에서는 이와 같은 문제점을 해결하고자 아크방전을 이용해 플라이애시의 표면을 개질하는 연구를 진행하였다.

  • PDF

Recyling and refining of molybdenum scraps by vacuum arc melting (진공(眞空) 아크 용해(溶解)에 의한 몰리브덴 스크랩의 재활용(再活用) 및 정련(精鍊))

  • Lee, Back-Kyu;Oh, Jung-Min;Lee, Seoung-Won;Kim, Sang-Bae;Lim, Jae-Won
    • Resources Recycling
    • /
    • v.20 no.5
    • /
    • pp.40-45
    • /
    • 2011
  • We carried out to investigate the refining effect of molybdenum by Ar-H$_2$ vacuum arc melting(VAM) process for recycling Mo scrap. The purity of the Mo metals refined by VAM was evaluated using glow discharge mass spectromety(GDMS). From the result of GDMS, most impurities in the Mo metals except for W were removed by Ar-H$_2$ VAM down to a few mass ppm levels. The purity of the refined molybdenum scrap was improved up to 4N5(99.995%) from 3N(99.95%) of the initial Mo scrap. The amount of gaseous impurities such as C, N, and O in Mo scrap were decreased from 1290 ppm to 132 ppm. As a result, it is considered that a possibility of refining and cost-effective method for recycling Mo scrap by Ar-H$_2$ vacuum arc melting process was confirmed in this study.

The measurement of three-dimensional temporal behavior according to the pressure in the plasma display panel (플라즈마 디스플레이 패널의 압력별 3차원 시간 분해 측정)

  • Kim, Son-Ic;Choi, Hoon-Young;Lee, Seok-Hyun;Lee, Seung-Gol
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1628-1630
    • /
    • 2002
  • In this paper, we measured 3-dimensional temporal behavior of the light emitted from discharge cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. The detected light signal through the PM tube is sent on the oscilloscope and oscilloscope which is connected to PC with GPIB. The whole system is controlled by a PC. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300torr, 400torr, 500torr pressure. The top view of panel shows that the discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. At the 300torr, initial emission time is very fast. The side view of panel shows that the light is detected up to $150{\mu}m$ height of barrier rib. In the panel of 300torr, emission distribution is wider than the others.

  • PDF

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field (불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

Analysis of hydrological characteristics of Yongdam Dam experimental basin (용담댐 시험유역 특성자료분석 연구)

  • Hwang, Eui-Ho;Chae, Hyo-Sok;Lee, Geun-Sang;Koh, Deuk-Koo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1444-1449
    • /
    • 2006
  • Korea is about 70% of all country to mountain, and basin is consisted of various terrain, soil, vegetation, land use etc. because use land as intensive. Also, need basin hydrologic model that can analysis base outflow as well as outflow directly for calculation of discharge to establish irrigation plan. Inconvenient in use method and user interface offer side is causing by way that existing USGS WEASEL runs in PC Arc/Info, and ArcGIS with development of present GIS technology is applied in many fields offering convenience in analysis that use GIS. In this research, wished to develop suitable outflow parameter extraction system, For this, develop pre-processor and post-processor that effectively draw of hydrologic model input data from water resources DB through van example benchimarking, and developed input/output component of GIS base applicable to various hydrologic and water quality model.

  • PDF

DEVELOPMENT OF COMBIND WELDING WITH AN ELECTRIC ARC AND LOW POWER CO LASER

  • Lee, Se-Hwan;Massood A. Rahimi;Charles E. Albright;Walter R. Lempert
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.176-180
    • /
    • 2002
  • During the last two decades the laser beam has progressed from a sophisticated laboratory apparatus to an adaptable and viable industrial tool. Especially, in its welding mode, the laser offers high travel speed, low distortion, and narrow fusion and heat-affected zones (HAZ). The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. Although high-power laser beams have been combined with the plasma from a gas tungsten arc (GTA) torch for use in welding as early as 1980, recent work at the Ohio State University has employed a low power laser beam to initiate, direct, and concentrate a gas tungsten arcs. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process known as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma (LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well focused melted spots.

  • PDF

Evaluation of Estimated Direct Runoff and Non-point Pollutant Discharge from Upper Watershed of Daecheong Reservoir Using L-THIA Model (대청호 상류유역의 직접유출 및 비점오염배출부하 적용성 평가를 위한 L-THIA 모델)

  • Choi, Jae-Wan;Shin, Min-Hwan;Shim, In-Keun;Lee, Jae-An;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1139-1143
    • /
    • 2010
  • 대청호 수질관리를 위한 대책 수립시 상류유역의 유출 및 오염부하배출 특성을 평가하는 것이 중요하다. 유역의 수환경 영향을 평가하기 위해서 복잡한 수문 수질 모델을 이용하는데 사용자 편의성을 고려한 모델 개발과 이용이 필요하다. L-THIA ArcView GIS 모형은 토지이용도, 토양도, 일강우 자료만으로 직접유출의 모의가 가능하여 전 세계적으로 널리 이용되고 있다. 본 연구에서는 L-THIA ArcView GIS 모형을 이용하여 대청호 상류유역인 안내천, 월외천 유역의 직접유출 및 비점오염 배출부하 특성을 평가하였다. 직접 유출량 평가 결과, 결정계수($R^2$)와 유효지수(EI)가 월외천 유역 및 안내천 유역에서 각각 0.95, 0.93 및 0.81, 0.71로 나타나, L-THIA ArcView GIS 모형이 실측치를 잘 재현하는 것으로 나타났다. 강우유출수에 포함된 SS 및 T-P 오염부하량 평가결과, 결정계수($R^2$)가 월외천 유역과 안내천 유역에서 각각 0.53, 0.95 및 0.89, 0.89로 평가되었다. 또한 유효지수(EI)가 월외천 유역과 안내천 유역에서 각각 0.44, 0.95 및 0.98, 0.99로 평가되었다. SS 부하량 평가 결과에서 월외천 유역이 안내천 유역보다 정확성이 낮은 것은 지역특성에 따라 SS 부하량 차이가 크기 때문이다. 따라서 L-THIA ArcView GIS 모형의 지속적인 개선이 이루어진다면 대청호 만입부 상류유역에서의 각종 수질관리대책 평가에 활용될 수 있을 것으로 판단된다.

  • PDF

Properties of AlTiN Films Deposited by Cathodic Arc Deposition (음극 아크 증착으로 제조된 AlTiN 박막의 특성)

  • Yang, Ji-Hoon;Kim, Sung-Hwan;Song, Min-A;Jung, Jae-Hun;Jeong, Jae-In
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The properties of AlTiN films by a cathodic arc deposition process have been studied. Oblique angle deposition has been applied to deposit AlTiN films. AlTiN films have been deposited on stainless steel (SUS304) and cemented carbide (WC) at a substrate temperature of $500^{\circ}C$. AlTiN films were analyzed by scanning electron microscopy, glow-discharge light spectroscopy, micro-vickers hardness, and nanoindenter. When applying a current of 50 A to the cathodic arc source, it showed that the density of macroparticle of AlTiN films was 5 lower than other deposition conditions. With the increase of the bias voltage applied to the substrate up to -150 V, the density of macroparticle was decreased. The change of the $N_2$ flow rate during coating process made no influence on the film properties. For the multi-layered films, the film prepared at oblique angle of $60^{\circ}$ showed the highest hardness of 28 GPa and $H^3/E^2$ index of 0.18. AlTiN films have been shown a good oxidation resistance up to $800^{\circ}C$.

Study on Measurement Method of Dielectric Recovery Voltage to analysis Dielectric Recovery Characteristic of Molded Case Circuit Breaker (저압 배선용차단기 절연회복특성 파악을 위한 절연회복전압 측정기법 연구)

  • Song, Tae-Hun;Cho, Young-Maan;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.49-54
    • /
    • 2015
  • Molded Circucit Breaker(MCCB) is a most widely used device to protect loads from the over-current in low power level distribution system. When the MCCB interrupts the over-current, the arc discharge occurred between fixed contact and moving contact to create hot gas. By the Lorentz force due to arc current, the occurred arc is bent to the grids. The grids extend and cool and divide it for arc extinguish. In the majority cases, the MCCB protects loads by interrupting the over-current successfully but in some cases the re-ignition is occurred by hot-gas created during process of interruption. The re-ignition arises when the recovery voltage(RV) is more higher than the recovery strength between contacts and it leads to interruption fault. Therefore to find out the dielectric recovery characteristics of protecting device has a great importance for preventing interruption fault. In this paper, we studies measurement method of the dielectric recovery characteristics considering inherent attribute of the MCCB. To measure the dielectric recovery characteristic of MCCB, we makes an experiment circuit for applying the over-current and the randomly recovery voltage. The measurement methode to find out the dielectric recovery voltage of the MCCB was established and the result was based on experiment results.