• 제목/요약/키워드: Ar-$H_2$

검색결과 960건 처리시간 0.032초

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

Ag-25wt% Pd-15wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效京華特性) (The Effect of Au Addition on the Hardening Mechanism in Ag-25wt% Pd-15wt% Cu)

  • 배봉진;이화식;이기대
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.37-49
    • /
    • 1998
  • 실용치과재료로 사용되고 있는 Ag-Pd-Cu 3 원계 합금의 시효석출과정을 Pd 및 Cu의 용질 농도의 조성비가 약 1.7인 합금과 이 합금에서 2wt%Au의 첨가합금에 미치는 영향을 조사 분석하여 아래와 같은 결론을 얻었다. Ag-25Pd-15Cu 3원 합금은 ${\alpha}$의 단일상에서 ${\alpha}_1$ (Cu-rich), ${\alpha}_2$(Ag-rich) 및 PdCu 규칙상에 의해서 경화반응이 진행되며 연속승온시효에 의하면 $100{\sim}300^{\circ}C$의 저항증가와 $300{\sim}500^{\circ}C$의 저항감소라고 하는 2단계 변화에 의해서 경화곡선이 얻어졌다. 또한 본 합금의 시효과정은 ${\alpha}{\to}{\alpha}+{\alpha}_2+PdCu{\to}{\alpha}_1+{\alpha}_2+PdCu$이고 2상분리 반응에 경화되며 최고경화는 ${\alpha}_1,\;{\alpha}_2$ 및 PdCu 규칙상의 혼합영역에서 나타났다. 이들 석출반응은 입계반응이고 반응의 진행과 함께 경도값은 상승하고 경화촉진에 기여하였다. 또한 Nodule은 미세한 lamella조직을 나타내고 이들 ${\alpha}_2$와 PdCu상과의 미세한 혼합상의형성이 시효경화에 기여하는 주된 원인이 되었다. 과시효는 lamella의 조대화와 PdCu상의 ${\alpha}2$상으로의 용해에 따른 정량적 감소에 대응하였다. 석출상은 thin lamella구조의 잘 방위된 미세한 판상석출물로서 이들 미세 판상석출물은 AuCu($L1_0$)type의 face-centered tetragonal(fct)의 초격자구조였다. 규칙화된 미세한 판상석출물은 stair-step mode로서 twinning에 의해 형성되며 이것은 시효에 의해 $L1_0$ type의 PdCu 규칙상과 같은 초격자 형성시 정방비틀림 때문이라고 생각된다. 이들 twinning lamella는 귀금속원소에 의해 형성된 $L1_0$ type의 PdCu 규칙상과 같기 때문에 이들 합금의 부식저항에도 기여하였다. Ag-25Pd-15Cu합금은 전반적으로 양호한 내식성을 나타내며 Pd.Cu=1인 합금에서보다도 Pd함량이 높은 Pd/Cu=1.7에서 내식성이 보다 우수한 것은 Pd 함량이 내식성에 기여하였고 2%Au의 첨가에 의해서 부식성을 개선할 수 있었다.

  • PDF

CBD(Chemical Bath Deposition)방법에 의한 ZnSe 박막성장과 광전기적 특성 (Growth and Opto-electric Characterization of ZnSe Thin Film by Chemical Bath Deposition)

  • 홍광준;유상하
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.62-70
    • /
    • 2001
  • CBD방법으로 성장하여 $450^{\circ}C$로 열처리한 ZnSe 박막은 회전 무늬로부터 외삽법으로 구한 격자상수 $a_0$$5.6678\;{\AA}$인 zinc blend임을 알았다. Van der Pauw 방법으로 측정한 Hall 데이터에 의한 이동도는 10 K에서 150 K 까지는 불순물 산란 (impurity scatterimg)에 의하여, 150 K에서 293 K까지는 격자산란 (lattice scattering)에 의하여 감소하는 경향을 나타냈다. 또한 운반자 농도의 ln n대 1/T에서 구한 활성화 에너지($E_a$)는 0.27 eV였다. 투과 곡선의 투과단으로 본 띠 간격은 293 k에서 $2,700{\underline{5}}\;eV$이었던 것이 10K에서는 $2.873{\underline{9}}\;eV$로 변하였다. 광전류 봉우리 위치를 투과단과 비교할 때 293 K에서 30 K까지 관측된 한 개의 봉우리는 가전자대 ${\Gamma}_8$에서 전도대 ${\Gamma}_6$로 전이에 의한 광전류 봉우리이고, 10K에서 관측된 단파장대 417.3 nm($2.971{\underline{4}}\;eV$)의 봉우리는 가전자대 ${\Gamma}_7$에서 전도대 ${\Gamma}_6$로, 431.5 nm($2.873{\underline{3}}\;eV$)의 봉우리는 가전자대 ${\Gamma}_8$에서 전도대 ${\Gamma}_6$로 전이에 의한 광전류 봉우리가 관측된 것으로 판단된다. 광전류 봉우리의 10K에서 단파장대의 가전자대 갈라짐(splitting)에 의해서 측정된 ${\Delta}so$(spin orbit coupling)는 $0.098{\underline{1}}\;eV$ 였다. 10 K에서 광발광 봉우리의 440.7 nm($2.812{\underline{7}}\;eV$)는 자유 엑시톤(free exciton : $E_x$), 443.5 nm ($2.795{\underline{5}}\;eV$)는 주개-얽매인 엑시톤(donor-bound exciton) 인 $I_2(D^0,\;X)$와 445.7 nm ($2.781{\underline{8}}\;eV$)는 반개-얽매인 엑시톤(acceptor-bound exciton) 인 $I_1(A^0,X)$이고, 460.5 nm ($2.692{\underline{3}}\;eV$)는 주개-받개쌍(donor-acceptor pair:DAP) 발광, 580 nm ($2.137{\underline{6}}\;eV$)는 self activated(A)에 기인하는 광발광 봉우리로 분석된다.

  • PDF

광신 연 - 아연 광상의 유체포유물 및 안정동위원소 연구 (Fluid Inclusion and Stable Isotope Studies of the Kwangsin Pb-Zn Deposit)

  • 최광준;윤성택;소칠섭
    • 자원환경지질
    • /
    • 제30권6호
    • /
    • pp.505-517
    • /
    • 1997
  • 광신 연-아연 광산은 단층 열극을 충진한 열극 충진 광상으로서 조선계의 삼태산층과 시대미상의 서창리층에 발달된 석영과 탄산엽맥으로 이루어져 있다. 광화작용은 3회에 걸쳐 진행되었으며, 각 광화시기의 특징은 다음과 같다. 광화 I기=barren한 석영의 침전기, 광화 II기=석영과 능망간석에 수반된 연-아연 광물의 주 침전기, 광화 III기=barren한 방해석의 침전기. 특히, 연-아연 광물은 주로 광화 IIb기에 침전하였다. 유체포유물 연구에 의하면, 광화 IIb기 광화유체의 온도와 염농도는 $182^{\circ}{\sim}276^{\circ}C$와 2.7~5.4 wt. % NaCl 상당 염농도였으며, 연-아연 광물의 침전은 주로 비등작용과 더불어 후기의 천수 혼입작용에 기인하였음을 지시한다. 광화작용은 약 600~700 m의 심도에서 이루어진 것으로 판단된다. 섬아연석과 유비철석의 성분 함량을 이용하여 추정한 광화 IIb기의 황분압($log\;fs_2$)은 -15.5~11.8 atm이다. 황화물의 황동위원소 조성 (${\delta}^{34}S_{CDT}=9.0{\sim}14.5$ ‰)에 근거한 열수유체의 전(全) 황동위원소값 (${\delta}^{34}S_{{\Sigma}S}$)은 약 14 ‰로서 매우 높은데, 이는 심부 화성기원의 황이 퇴적암류내의 황산염과 다소 혼합 된 결과로 사료된다. 산소-수소 동위원소 분석 연구에 의하면, 광화유체는 낮은 수-암비 환경 하에서 주로 주변 모암인 삼태산층 (${\delta}^{18}O=20.1{\sim}24.9$ ‰)과 상당히 반응한 심부 순환 천수로부터 형성되었다. 한편, 광화유체의 산소동위원소값 (${\delta}^{18}O_{H2O}$)은 광화작용의 진행과 더불어 체계적으로 감소 (광화 I기, 14.6~10.1 ‰; 광화 IIa기, 5.8~2.2 ‰; 광화 IIb기, 0.8~-2.0 ‰; 광화 IIc기, -6.1~-6.8 ‰)하였다. 이는 열수계 내로의 천수 혼입이 시간 경과와 더불어 점진적으로 증가하였음을 지시한다.

  • PDF

대동맥교약증 환아의 해부학적 형태, 동반심기형, 연령, 수술방법등이 수술결과에 미치는 영향 (Influence of Anatomy, Associated Anomalies, Age, and Surgical Methods on the Surgical Results of Aortic Coarctation)

  • 이정렬;김혜순
    • Journal of Chest Surgery
    • /
    • 제30권4호
    • /
    • pp.363-372
    • /
    • 1997
  • 본 연구는 1986년 6월 3일부터 1995년 12월 31일까지 서울대학교 어린이 병원 흉부외과에서 경험한 144례의 대동맥 교약증 환아를 대상으로, 술후 결과에 영향을 미치는 여러 가지 요소들을 분석하였다. 환아의 평균 연령은 15.73+32.43(범 위 0.1-191.0, 중앙값=3.3)개월이 었고, 이중 11)례(78.5%)의 환아는 영아, 25례(17.4%)는 신생아였다. 환아를 대동맥궁 협 착 부위와 동반 심기형에 따라(제 1형:국소 협착, 제2형:대동맥 헙부 협착, 제3형 :대동맥 협부 및 횡대동맥궁 협착, h:심실중격결손증 동반, B:기타 복 잡 심기 형 동반) 9가지로 분류한 결과, 1, IA, IB, I, IIA, IIB, III, IIIA, IIIB형이 각각 25, 9, 6, 24, 35, 15, 4, 19, 7례 였다. 수술방법은 쇄골하동맥편 교약성형술(subclavian-flap coarctoplasty, SFC: 60례), 절단 및 문합술(resection and anastomo sis, R&A: 44례), 확장된 대동맥성형술(extended aortoplasty, Ex-Ao: 26 례), 덮개포편술(onlay patch, Onlay: 14례)이 사용되었다. 총수술 사망률은 16.0%(23/144)였고, 수술 사망률을 높이는 인자로 협착부위(I, II, III형) 동반 심기형(0, A, B), 환아의 연령, 수술방법, 단계수술 \ulcorner부 등이 분석되었는데 이중 횡대동맥궁협착을 동반하는 III형(I형 사망률=2.5%(1/40), II형=17.6% (13/74), III형=30%(9/30); p(0.01), B형(0형 사망률=3.8%(2/53), A형 =15.9%(10/63), B형 =39.3%(11/28); p(0.01) 등이 의미있는 위험 인자였다. 생존환아 121례는 술후 평균 29.1+28.8(범위 0-129.2)개월 외래 추 적되 었으며 이중 술후 협착을 보였던 경우는 18례로 14.9%의 헙착률은 보였다. 생존환자중 77례의 환자 (I형 20명. ll형 42명, 111형 15명)에서 술전, 술후 3개월 이내, 술후 6개월이후의 심에코도상의 대동맥 각 부위 크기에 관한 자료의 입수가 가능하였으며 이를토대로무명동맥 직근위부의 상행대동맥 직경에 대 한 대동맥협부 직경의 비율(대동맥협부지수)및 경동맥부위의 횡대동맥 직경비율(횡대동맥지수)을구하 여 형태 별로 술전, 수술 직후 6개월이상 경과후의 대동맥 크기 변화의 양상을 관찰하였다. 제 I, II, III형 모두에서 술전에 비하여 술후 평균 대동맥협부지수의 의미있는 증가가 관찰되었으며(p<0.01),제 III형에서는 횡대동맥지수의 의미있는 증가도 관찰되었다(p<0.01). 재헙착으로 진단된 I, II형의 수술직후 대 동맥협부지수와 111형의 횡대동맥 지수는 비협착군에 비하여 의미있게 작았는데 이는 아마도수술 당시 협 착 부위의 완전제거가 이루어지지 않은 것이 원인이라고 사료되었다. 본 분석에서는 어린 연령(3개월 이하), 3개월이하에 시행한 쇄골하동맥편 교약성형술이 의미있는 재협착의 위험요소로 밝혀졌다. 결론 적으로 저자등은 본연구를 통하여 대동맥협부지수, 횡대동맥 지수 등이 개개 대동맥교약 환아의 해부학 적, 임상적 특징을 파악하는데 도움이 되는 도구라는 사실을 발견하였고 아울러 교약의 해부학적 특성, 동반 심기 형, 연령, 수술방법 등이 수술사망 및 재협착에 영향한다는 사실을 입증하였다.

  • PDF

찰벼 품종에 따른 소곡주의 이화학적 특성 (Waxy Rice Variety-dependent Variations in Physicochemical Characteristics of Sogokju, a Korean Traditional Rice Wine)

  • 이진석;우관식;천아름;나장연;김기종
    • 한국작물학회지
    • /
    • 제54권2호
    • /
    • pp.172-180
    • /
    • 2009
  • 품종에 따라 제조된 소곡주의 이화학적 특성을 검토하기 위하여 원료로 사용된 보석찰, 동진찰, 해평찰, 화선찰, 눈보라, 상주찰, 신선찰의 특성을 검토한 결과 수분함량은 큰 차이를 보이지 않는 것으로 나타났으며, 단백질 함량은 상주찰이 8.11%로 가장 높게 나타났고 눈보라가 6.35%로 가장 낮은 함량을 나타내었다. 백도는 화선찰이 가장 높았으며, 보석찰이 가장 낮은 수치를 보였다. 색도를 측정한 결과 L값의 경우 백도와 비슷한 결과를 나타내었으며, a 및 b값은 보석찰이 0.35 및 13.09로 가장 높은 수치를 나타내었다. 호화특성 중 호화개시온도는 $68.03{\sim}68.08^{\circ}C$로 유의적인 차이를 보이지 않는 것으로 나타났으며, 강하점도는 보석찰 및 신선찰이 높은 것으로 나타났고 치반점도는 상주찰이 가장 높게 나타났다. 품종별로 제조된 소곡주의 알코올 함량은 품종별로 큰 차이를 보이지 않는 것으로 나타났다. 당도는 $20.5{\sim}24.6\;^{\circ}Bx$로 나타났고 탁도는 $0.0344{\sim}0.0530$ 범위로 나타났다. L 및 b값은 상주찰이 각각 6.90 및 1.45로 가장 높은 수치를 보였다. pH는 상주찰이 4.79로 가장 높았으며, 나머지는 $4.70{\sim}4.74$의 범위로 큰 차이가 없는 것으로 나타났다. 총산도는 상주찰이 0.8684%로 가장 높게 나타났으며, 그 외 품종은 $0.7998{\sim}0.8360$%의 범위로 나타났다. 품종별로 제조된 소곡주의 유리당은 glucose만 검출되었으며, 상주찰과 동진찰이 각각 10.843 및 10.331 g/100 mL로 높은 함량을 나타내었다. 유기산 함량을 측정한 결과 succinic acid, malic acid, citric acid 및 oxalic acid 등이 검출되었다. 품종별로 제조된 소곡주의 동진찰을 기준으로 하여 나머지 품종에 대한 관능검사를 실시한 결과 신선찰, 해평찰 및 화선찰이 비교적 양호한 결과를 나타내었다.

대두근류균(大豆根瘤菌) 접종(接種)이 뿌리와 줄기 즙액중(汁液中) Amide-N 및 Ureide-N 농도(濃度)에 미치는 영향(影響) (Effects of Rhizobium Inoculation on the changes of Ureide-N and Amide-N Concentration in Stem and Root exudate of Soybean Plant)

  • 고재영;서장선;이상규
    • 한국토양비료학회지
    • /
    • 제22권4호
    • /
    • pp.329-336
    • /
    • 1989
  • 대두식물(大豆植物) 조직중(組織中)의 함질소화합물(含窒素化合物)의 변화(變化)를 알고져 우리나라 콩재배지(栽培地) 밭토양(土壤)에서 분리(分離)한 근류균(根瘤菌)을 접종(接種)하고 시비양(施肥量)을 달리 했을 때, 온실(溫室)에서 재배(栽培)한 대두(大豆)의 줄기와 뿌리중의 즙액내(汁液內) amide-N 및 ureide-N의 경시적(經時的) 변화(變化)를 조사(調査)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 전국(全國) 밭토양(土壤) 22개(個) 지점(地點)의 37개(個) 표토(表土)에서 89종(種)의 근류균(根瘤菌)을 선발(選拔)하고 이 중에서 질소고정력(窒素固定力)(acetylene 환원력(還元力))이 6.4~20.1 nmol/hr/tube되는 5종(種)을 분리동정(分離同定)하였다. 2. 분리(分離)한 5종(種)의 토착근류균(土着根瘤菌)은 질산환원(窒酸還元) 효소(酵素)의 활성(活性)이 아주높고 암모니아 및 아질산(亞窒酸) 산화효소(酸化酵素) 활성(活性)이 낮았으며 접종재배시험(接種栽培試驗)에서는 Rhizobium japonicum Rjk-134를 공시(供試) 사용(使用)하였다. 3. 근류균(根瘤菌) 접종시(接種時) 무비(無肥) 및 무질소구(無窒素區)에서 대두(大豆)의 건물중(乾物中)이 증가(增加)되었고 질소단용구(窒素單用區) 및 삼요소시비구(三要素施肥區)에서는 건물중(乾物重)이 감소(減少)되었다. 4. Amide-N 및 ureide-N 농도(濃度)는 뿌리보다 줄기즙액내(汁液內)에서 그리고 생육시기별(生育時期別)로는 파종(播種) 30일(日) 이 45일(日)보다 현저(顯著)히 높은 농도(濃度)를 보였다. 5. 뿌리 및 줄기 중(中)의 amide-N 및 ureide-N의 농도(濃度)는 시비구(施肥區)의 근류균(根瘤菌) 접종구(接種區)에서 높고 또한 무비구(無肥區)의 무접종구(無接種區)에서 높았다. 6. 식물체중(植物體中) 줄기와 뿌리의 암모니아태(態) 질소농도(窒素濃度)는, 무비구(無肥區)와 무질소구(無窒素區)는 근류균(根瘤菌) 무접종구(無接種區)에서 높고 질소단용구(窒素單用區) 및 삼요소시용구(三要素施用區)는 접종구(接種區)에서 현저(顯著)히 높은 농도(濃度)를 보였다.

  • PDF

창작그림동화의 독창성 연구 (Original expression of the creative chidren's picture-book)

  • 안경환
    • 디자인학연구
    • /
    • 제11권1호
    • /
    • pp.185-197
    • /
    • 1998
  • 국내 출판시장 규모는 (문화체육부 통계자료) 세계 시장 규모 7위로, 아동도서 출판 이 세계 3위 수준에 달하는 출판현황은 그 양적 성장에 비하여 책이 종류와 장르의 은 한정되고 있는 상황이다. 외국의 아동 출판계는‘복합출판’으로 동화 한 종을 보더라도 인형, 오디오, 게임, CD롬 타이틀 등을 동시에 내놓는 상황으로, 심지어 기획단계 부터 비디오(만화영화)도 고려한다. 이에 비해 국내 아동출판의 대부분은 학습지가 점유하고 있다. 90년대 들어 고학력 부모들의 신중한 책 선택도 아동 출판계의 변화 배경으로 꼽힌다. 이런 풍요 속 빈곤의 문제점은 $^{(1)}$지난해(1997)나온, 우리 그림책의 1백 90여권이 번역물로, 실리적 측면에서 국내 기획물 이 빈약한 실정이다. “강아지 똥”은 국내기획의 창작 그림책 중 1만 5000부가 나가는 상업적 성공을 거둔 것을 보면, 기획력에 따라 우리 창작물도 얼마든지 시장을 확보할 수 있음을 제시한다. 자연이 소중함을 한국적 삽화와 곁들여 출판한“강아지 똥”창작그림동화책의 인기는 판매량 면에서도, 많은 독자들의 우리 책 선호를 알 수 있다. 본 연구는 우리나라 창작동화의 전망 찾기의 모토로서, 어린이 창작그림동화책 가운데 $^{(2)}$베스트셀러로서 외국 번역창작동화그림책“누가 내 머리에 똥 쌌어”과 우리의 창작그림동화책인“강아지 똥”을 그림동화 기획(주제, 글, 일러스트, 편집디자인)의 독창적 구성요소들을 중심으로 연구.검토하여, 세계 속의 한국의 창작그림동화책 만들기를 보다 전문적이고 예술성 높은 그림책의 내적 구조, 창의성(글과 그림)의 관계, 이미지의 풍부한 내용을 표현한 새로운 조형언어를 통하여 어린이를 위한 출판그림의 우수성 향상을 목적으로, 장르별로 문학적.예술적.교육적 요소를 포함한 우리 창작그림동화책 기획 및 발전의 계기를 부여함으로써, 우리 어린이에게 궁극적으로는 삶의 가치를 높여주는‘이야기가 담겨진 그림이 있는 책’인 좋은 창작그림동화책의 기획을 예시하고자 한다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF