• 제목/요약/키워드: Aquifer storage

검색결과 119건 처리시간 0.028초

지하대수층을 이용한 축열시스템의 설계(II) : 열해석 (Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis)

  • 이관수;이태희;송영길
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

변동량 분석을 이용한 암반대수층의 수리학적 매개변수 산출 (Estimation of Hydraulic Parameters of a Fractured Rock Aquifer Using Derivative Analysis)

  • 김범수;양동철;여인욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.46-52
    • /
    • 2010
  • Derivative analysis, based on the derivative of the drawdown as a function of time (i.e., rate of drawdown change), was applied to the evaluation of hydraulic parameters of the aquifer as an aid of the aquifer test interpretation based on the Theis solutions. Pumping tests were conducted at a coastal fractured aquifer in Muan county, Korea, of which the drawdown data, measured at the two observation wells, were used for derivative analysis. Wellbore storage and transition period were hard to identify at conventional log-log and semi long plots, but was easily recognized by distinctive curves of positive unit slope, hump and negative unit slope in the derivative plot. For the observation well of OW-2 at which wellbore storage and transition lasted over an hour, conventional aquifer analysis would suffer from the uniqueness problems and in further result in erroneous hydraulic parameters. Derivative analysis was found to be effective for distinguishing the drawdown data directly reflecting the aquifer property from those reflecting non aquifer effects such as wellbore storage and transition, which offers a unified methodology to yield correct hydraulic parameters from aquifer test data.

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

대수층 축열 에너지 활용 모델의 온도 분포 시뮬레이션 연구 (A study of the simulation of thermal distribution in an aquifer thermal energy storage utilization model)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.697-700
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop an ATES system which has certain hydrogeological characteristics, understanding of the thermo hydraulic processes of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermo hydraulic transfer for heat storage is simulated using FEFLOW according to two sets of pumping and waste water reinjection scenarios of heat pump operation in a two layered confined aquifer. In the first set of model, the movement of the thermal front and groundwater level are simulated by changing the locations of injection and pumping well in seasonal cycle. However, in the second set of model the simulation is performed in the state of fixing the locations of pumping and injection well. After 365 days simulation period, the temperature distribution is dominated by injected water temperature and the distance from injection well. The small temperature change is appears on the surface compared to other slices of depth because the first layer has very low porosity and the transfer of thermal energy are sensitive at the porosity of each layer. The groundwater levels and temperature changes in injection and pumping wells are monitored to validate the effectiveness of the used heat pump operation method and the thermal interference between wells is analyzed.

  • PDF

대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석 (Hazardous event analysis in drinking water production using aquifer storage transfer and recovery)

  • 이상일;지현욱
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링 (Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

균열대수층내 지하수유동에 관한 이중투수율 프락탈모델 (Dual-permeability Fractal Model of Groundwater Flow in Fissured Aquifers)

  • ;함세영
    • 자원환경지질
    • /
    • 제30권5호
    • /
    • pp.433-442
    • /
    • 1997
  • 균열암반 이중대수층 (1대수층과 2대수층)내 지하수흐름을 모식화한 프락탈모델이 개발되었다 이때 양수정내 지하수유입은 1대수층에서만 유래한다. 본 모델은 우물저장과 우물손실을 고려할 수 있어서 양수초기의 지하수위 변화를 정확하게 파악할 수 있는 잇점이 있다. 여러 가지 유동차원에 대해서, 1대수층의 수리전도도가 2대수층보다 더 크고, 비저유율이 2대수층보다 더 낮은 경우 (case 1)와 1대수층의 수리전도도가 2대수층보다 더 작고, 비저유율이 2대수층보다 더 큰 경우 (case 1)에 대해서 표준곡선을 작성하였으며, 이들 곡선의 특성을 분석하였다. 본 모델은 양수정과 관측정의 수위하강이 서로 다른 거동을 보여주는 양수시험자료를 해석하는데 유용하게 쓰일 수 있을 것이다.

  • PDF

대수층 축열시스템의 열거동에 관한 실험적 연구 (An Experimental Study on the Thermal Behavior of Aquifer Thermal Energy Storage System)

  • 이세균;문병수;남승백;김기덕
    • 대한기계학회논문집
    • /
    • 제16권9호
    • /
    • pp.1780-1787
    • /
    • 1992
  • 본 연구에서는 대수층을 시뮬레이션한 실험장치를 통하여 온도분포를 관찰하 고 자연대류에 관한 단순화된 이론적 모델을 개발하여 실험치와 비교 검토하고자 한 다.

분할유동차원 2층 대수층에서의 투수성, 층간흐름, 저류성의 효과 (Permeability, crossflow and storativity effects in two-layer aquifer system with fractional flow dimension)

  • 함세영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.81-84
    • /
    • 2000
  • Two-layer aquifer system with fractional flow dimension is composed of contiguous two layers: Layer 1 (lower layer) and Layer 2 (upper layer) with different permeability and specific storage each other. For this aquifer system, we assume that groundwater flow originates only from Layer 1 on the pumping well. The aquifer system considers wellbore storage and skin effects on the pumping well. Dimensionless drawdown curves for different flow dimensions are analyzed for different lambda (λ, crossflow coefficient) values, kappa ($textsc{k}$, permeability ratio between Layer 1 and Layer 2) values and omega ($\omega$, storativity ratio between Layer 1 and Layer 2) values. The curves for Layer 1 and Layer 2 show characteristic trend each other.

  • PDF

대수층 축열 에너지(ATES) 시스템 모델에서 지하수 유동 영향에 의한 지반내 온도 분포 예측 시뮬레이션 (Simulation of thermal distribution with the effect of groundwater flow in an aquifer thermal energy storage (ATES) system model)

  • 심병완
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having the effect of groundwater movement, understanding of thermohydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated by using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.001 are shaped circular, and the center is moved less than 5 m to the direction of groundwater flow in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of east boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF